Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Méthode de radioprotection à coût zéro pour réduire l'exposition aux radiations des cardiologues interventionnels pendant les procédures coronaires percutanées transradiales (essai Freepadrad) (FREEPADRAD)

31 octobre 2026 mis à jour par: Georgios Latsios, National and Kapodistrian University of Athens

Ionising radiation is a recognised occupational hazard in interventional cardiology. This prospective, randomised trial aims to evaluate the effectiveness of additional radiation protection by existing devices but with a different use, specifically the use of medical lead aprons (designed and used to be worn by the medical and nursing staff for radiation protection) covering the patient's lower abdominal and pelvic area during transradial coronary angiography and angioplasty. The intervention's efficacy will be assessed by measuring the reduction in operator radiation exposure and determining the impact of various clinical and procedural factors.

Aperçu de l'étude

Description détaillée

Ionizing radiation refers to any type of radiation capable of interacting with matter. It plays a vital role in medical diagnostics and therapeutic applications. Imaging techniques allow for timely and accurate diagnosis, while advanced therapies contribute to longer life expectancy and improved quality of life. However, ionizing radiation carries inherent risks, making its controlled use essential. Radiation exposure is not immediately perceptible but can result in significant damage to the exposed organism. Common effects of high-dose exposure include ocular damage and skin injuries, while radiation is also associated with cellular-level damage, leading to an increased risk of malignancies. Exposure is proportional to time, inversely proportional to the square of the distance from the source, and accumulates over time.

Despite technological advancements and improved X-ray systems, the increasing complexity and frequency of interventional cardiology procedures have led to higher radiation exposure in catheterization laboratories. This poses a major occupational hazard for medical staff, highlighting the need for effective methods to reduce radiation exposure and protect healthcare professionals. Operator radiation exposure varies depending on experience, procedure type, patient characteristics, X-ray system features, and protective measures used. These measures include disposable gloves, shields, lead aprons, and robotic systems.

This prospective, randomised trial evaluates the efficacy of a cost-effective (namely zero-cost) and very easily utilised radiation protection strategy for interventional cardiologists during transradial coronary procedures. By applying a triple-layer lead apron to the patient's pelvic region, the study aims to reduce operator radiation exposure while maintaining standard procedural outcomes. The randomized controlled trial will compare the intervention group utilizing the additional shielding with a control group employing standard radiation protection methods. Key measurements include direct operator radiation exposure and its relation to patient-specific and procedural factors. Findings may establish a practical method for reducing the specific radiation-related occupational hazard related to modern transracial interventional cardiology.

Type d'étude

Interventionnel

Inscription (Réel)

198

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Attica
      • Athens, Attica, Grèce, 11527
        • First Department of Cardiology, Hippokration General Hospital of Athens
      • Athens, Attica, Grèce, 11527
        • First Department of Cardiology, National and Kapodistrian University of Athens, Hippokration General Hospital of Athens

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Patients undergoing transradial diagnostic coronary angiography or angioplasty.
  • Adults aged 18 years and older.
  • Informed consent provided.

Exclusion Criteria:

  • Acute STEMI requiring primary percutaneous coronary intervention (PCI).
  • Patients undergoing structural heart interventions.
  • Initially femoral access or crossover to femoral access procedures.
  • Patients unable to provide informed consent.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: La prévention
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Aucune intervention: Use of conventional radiation protection measures.

This group will undergo transradial coronary procedures using only conventional radiation protection measures. These include standard operator lead aprons, fixed protective drapes, and other standard shielding equipment typically employed in the catheterization laboratory. No additional radiation protection devices or techniques will be applied to the patient. This arm serves as the baseline for comparison with the intervention group.

Expérimental: Additional patient-applied pelvic lead shielding

This group will undergo transradial coronary procedures with the addition of a patient-applied pelvic lead shield. Alongside the conventional radiation protection measures used in the control group, a triple-layer lead apron will be placed over the patient's lower abdominal and pelvic region. This shield, composed of three 0.25 mm Pb-equivalent layers, is designed to reduce scatter radiation exposure to the operator. The intervention aims to assess the effectiveness of this additional protective measure in reducing operator radiation dose.

The intervention involves the application of a triple-layer lead apron to the patient's lower abdominal and pelvic region during transradial coronary procedures. The apron measures 75 cm × 45 cm and is composed of three layers of 0.25 mm Pb-equivalent material. This protective shield is placed on the patient in addition to standard operator radiation protection measures. The primary goal of this intervention is to reduce scatter radiation exposure to the operator, thereby improving occupational safety in the catheterization laboratory. This approach leverages existing radiation protection materials in a novel configuration.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Effectiveness of Patient-Applied Pelvic Shielding in Reducing Operator Radiation Exposure During Transradial Coronary Procedures
Délai: During the transradial coronary procedure, measured from the start to the completion of fluoroscopy.

Primary Outcomes:

Absolute Operator Radiation Exposure:

Direct measurement of operator exposure (µSv) using a dosimeter placed outside the lead apron at chest level.

During the transradial coronary procedure, measured from the start to the completion of fluoroscopy.
Effectiveness of Patient-Applied Pelvic Shielding in Reducing Operator Radiation Exposure During Transradial Coronary Procedures
Délai: During the transradial coronary procedure, measured from the start to the completion of fluoroscopy.

Primary Outcomes:

Relative Operator Radiation Exposure:

Measured as the ratio of operator exposure (µSv) to patient radiation dose area product (cGy·cm²).

During the transradial coronary procedure, measured from the start to the completion of fluoroscopy.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

30 janvier 2025

Achèvement primaire (Réel)

30 avril 2026

Achèvement de l'étude (Réel)

1 mai 2026

Dates d'inscription aux études

Première soumission

13 février 2025

Première soumission répondant aux critères de contrôle qualité

9 avril 2025

Première publication (Réel)

17 avril 2025

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

3 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

31 octobre 2026

Dernière vérification

1 octobre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner