- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT03185286
3D-Printed Personalized Metal Implant in Surgical Treatment of Ankle Bone Defects
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
Bone defects are common in ankle disease, and the conventional treatment includes autologous or allogeneic bone grafts. However, autologous bone graft may cause complications and its source is rather limited; allogeneic bone graft may cause disease transmission and the mechanical strength of the graft is low after processing.
The 3D printing technology has provided a new way of solving this problem. It has the following technical advantages: wide range of graft sources, high mechanical strength, and can be prepared in advance according to various shapes.
Preparation procedure: first, establish the individualized ankle model according to the patient's ankle CT scan data and then prepare the implant model; second, conduct surgery rehearsal and place the implant model in the ankle model for observation; third, after confirmation, use titanium alloy in the 3D printing machine to prepare the individualized metal implant, which is in line with the Chinese National Standard "Wrought titanium and titanium alloy for surgical implants" (GB/T 13810-2007); fourth, implant the individualized metal implant into the bone defect area after sterilization.
Tanulmány típusa
Beiratkozás (Várható)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
Chongqing
-
Chongqing, Chongqing, Kína, 400030
- Toborzás
- Southwest Hospital
-
Kapcsolatba lépni:
- Xiaojun Duan, MD
- Telefonszám: 86-23-68765290
- E-mail: duanxiaojun@hotmail.com
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Receive ankle or subtalar arthrodesis;
- Refuse to use autologous bone graft or allogeneic bone graft.
Exclusion Criteria:
- The local defect area is small;
- Refuse to use permanent metal metal implant.
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Kezelés
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: 3D-printed personalized metal implant
3D-printed personalized metal implant will be used in bone defect surgeries.
|
3d-printed personalized metal implant will be used in subtalar arthrodesis.
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Visual Analogue Scale (VAS)
Időkeret: Postoperative 24 months
|
The decrease in VAS score from baseline
|
Postoperative 24 months
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale
Időkeret: Postoperative 24 months
|
The increase in AOFAS score from baseline
|
Postoperative 24 months
|
|
Lower limb alignment
Időkeret: Postoperative 24 months
|
Analyze the lower limb alignment by radiography
|
Postoperative 24 months
|
|
Osteotylus growth
Időkeret: Postoperative 24 months
|
Analyze the osteotylus growth by radiography
|
Postoperative 24 months
|
|
Implant displacement
Időkeret: Postoperative 24 months
|
Assess the implant displacement by radiography
|
Postoperative 24 months
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Xiaojun Duan, MD, Southwest Hospital, China
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Várható)
A tanulmány befejezése (Várható)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- 3DIMPLANT
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .
Klinikai vizsgálatok a 3d-printed personalized metal implant
-
Dentsply InternationalMegszűntSzáj, fogatlanEgyesült Államok
-
Dentsply InternationalVisszavontSzáj, fogatlanEgyesült Államok
-
Baskent UniversityToborzás