- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03185286
3D-Printed Personalized Metal Implant in Surgical Treatment of Ankle Bone Defects
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Bone defects are common in ankle disease, and the conventional treatment includes autologous or allogeneic bone grafts. However, autologous bone graft may cause complications and its source is rather limited; allogeneic bone graft may cause disease transmission and the mechanical strength of the graft is low after processing.
The 3D printing technology has provided a new way of solving this problem. It has the following technical advantages: wide range of graft sources, high mechanical strength, and can be prepared in advance according to various shapes.
Preparation procedure: first, establish the individualized ankle model according to the patient's ankle CT scan data and then prepare the implant model; second, conduct surgery rehearsal and place the implant model in the ankle model for observation; third, after confirmation, use titanium alloy in the 3D printing machine to prepare the individualized metal implant, which is in line with the Chinese National Standard "Wrought titanium and titanium alloy for surgical implants" (GB/T 13810-2007); fourth, implant the individualized metal implant into the bone defect area after sterilization.
Tipo de estudio
Inscripción (Anticipado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Chongqing
-
Chongqing, Chongqing, Porcelana, 400030
- Reclutamiento
- Southwest Hospital
-
Contacto:
- Xiaojun Duan, MD
- Número de teléfono: 86-23-68765290
- Correo electrónico: duanxiaojun@hotmail.com
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Receive ankle or subtalar arthrodesis;
- Refuse to use autologous bone graft or allogeneic bone graft.
Exclusion Criteria:
- The local defect area is small;
- Refuse to use permanent metal metal implant.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: 3D-printed personalized metal implant
3D-printed personalized metal implant will be used in bone defect surgeries.
|
3d-printed personalized metal implant will be used in subtalar arthrodesis.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Visual Analogue Scale (VAS)
Periodo de tiempo: Postoperative 24 months
|
The decrease in VAS score from baseline
|
Postoperative 24 months
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale
Periodo de tiempo: Postoperative 24 months
|
The increase in AOFAS score from baseline
|
Postoperative 24 months
|
|
Lower limb alignment
Periodo de tiempo: Postoperative 24 months
|
Analyze the lower limb alignment by radiography
|
Postoperative 24 months
|
|
Osteotylus growth
Periodo de tiempo: Postoperative 24 months
|
Analyze the osteotylus growth by radiography
|
Postoperative 24 months
|
|
Implant displacement
Periodo de tiempo: Postoperative 24 months
|
Assess the implant displacement by radiography
|
Postoperative 24 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Xiaojun Duan, MD, Southwest Hospital, China
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 3DIMPLANT
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre 3d-printed personalized metal implant
-
Medacta International SAReclutamiento
-
Medacta International SAReclutamientoArtroplastia total de caderaSuiza
-
Mariam AlaaActivo, no reclutando
-
Amany IbrahimTerminado