Closing the Loop in Adults With Type 1 Diabetes - Alcohol Consumption (ANGELA02)
Randomised, Two-Period Crossover Study to Assess the Efficacy of Overnight Computer-based Glucose Control Compared With Conventional Pump Therapy Following the Consumption of Alcohol in Adults With Type 1 Diabetes
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
People with type 1 diabetes need regular insulin injections or continuous delivery of insulin using an insulin pump. Keeping blood sugars in the normal range is known to reduce the risk of long term complications involving the eyes, kidneys and heart. However, achieving treatment goals can be very difficult as the tighter we try to control blood glucose levels, the greater the risk of the person developing episodes of low glucose levels (hypoglycaemia). One solution is using a system where the amount of insulin injected closely matches the blood sugar levels on a continuous basis. This can be achieved by what is known as a "closed loop system" where a small glucose sensor placed under the skin communicates with a computer containing an algorithm that drives a subcutaneous insulin pump. This system is being developed in Cambridge and is undergoing trials in children and adults with type 1 diabetes. Results thus far show that the system is very effective at preventing hypoglycaemia and maintaining blood glucose levels in target range.
We plan to test the closed loop in various challenging conditions faced by patients in daily life. One of these is the consumption of alcohol, which can give rise to delayed hypoglycaemia in patients with diabetes. The studies will be done in a clinical research facility under supervised conditions. Subjects will attend for two study nights where they will receive a specific volume of alcohol with an evening meal. On one night this will be followed by closed loop algorithm control of their insulin overnight. On the other (control) night subjects will remain on their usual pump therapy regime overnight.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Cambridge, Regno Unito, CB2 0QQ
- Addenbrooke's Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Type 1 diabetes, as defined by WHO for at least 6 months or confirmed C-peptide negative
- On insulin pump therapy for at least 3 months
Exclusion Criteria:
- Non-type 1 diabetes mellitus
- Any physical/psychological disease likely to interfere with the study
- Taking medication likely to interfere with interpretation of results
- Known/suspected allergy against insulin
- Clinically significant nephropathy, neuropathy or retinopathy as judged by the investigator
- Unstable blood glucose control, including recurrent severe hypoglycaemia as judged by the investigator
- Current pregnancy/breastfeeding
- Total daily insulin dose > 1.4 IU/kg
- HbA1C > 10% within the last 3 months
- Unable/unwilling to consume the necessary quantity of alcohol stated in the study protocol
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione incrociata
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Closed loop (algorithm)
Subcutaneous delivery of Novorapid insulin, dose calculated by computer-driven control algorithm, based on continuous glucose sensor readings
|
Somministrazione sottocutanea di insulina Novorapid, dose calcolata dall'algoritmo di controllo, in base alle letture continue del sensore di glucosio
|
|
Comparatore placebo: Open loop
Subcutaneous delivery of Novorapid insulin according to usual pump regime
|
Somministrazione sottocutanea di insulina Novorapid secondo il normale regime della pompa
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Percentage of plasma glucose values in target (3.9-8.0 mmol/L)
Lasso di tempo: 2200-1200hr
|
2200-1200hr
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Percentage of CGM (continuous glucose monitoring) values in target (3.9-8.0 mmol/L)
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Percentage of plasma glucose and CGM values in target (3.9-8.0 mmol/L)
Lasso di tempo: 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Percentage of plasma glucose and CGM values below 3.9 mmol/L
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Percentage of plasma glucose and CGM values above 8.0 mmol/L
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Average plasma and CGM glucose
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Average plasma insulin concentration
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Total dose of insulin administered
Lasso di tempo: 2200-1200hrs
|
2200-1200hrs
|
|
Low blood glucose index (LBGI) score
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
High blood glucose index (HBGI) score
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
|
Percentage of plasma glucose and CGM values below 3.0 mmol/L
Lasso di tempo: 2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
2200-1200; 0000-0400; 0400-0800; 0800-1200; 0300-1200hrs
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Investigatore principale: Mark L Evans, MD FRCP, University of Cambridge, UK
- Direttore dello studio: Roman Hovorka, PhD, University of Cambridge, UK
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 09/H0306/44
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .