Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Convalida degli algoritmi di deep learning Belun Ring Gen3 con sensore corporeo subxifoideo

28 settembre 2026 aggiornato da: Belun Technology Company Limited

Algoritmi di deep learning Belun Ring Gen3 con sensore corporeo subxifoideo: esplorazione delle sue capacità diagnostiche per i disturbi respiratori del sonno con l'analisi delle dinamiche dei biomarcatori

Hypothesis: BR's Gen3 DL algorithms, combined with its subxiphoid body sensor, can accurately diagnose OSA, categorize its severity, identify REM OSA and supine OSA, and detect central sleep apnea (CSA).

Primary Objective:

To rigorously evaluate the overall performance of the BR with Gen3 DL Algorithms and Subxiphoid Body Sensor in assessing SDB in individuals referred to the sleep labs with clinical suspicion of sleep apnea and a STOP-Bang score > 3, by comparing to the attended in-lab PSG, the gold standard.

Secondary Objectives:

To determine the accuracy of BR sleep stage parameters using the Gen3 DL algorithms by comparing to the in-lab PSG;

To assess the accuracy of the BR arrhythmia detection algorithm;

To assess the impact of CPAP on HRV (both time- and frequency-domain), delta HR, hypoxic burden, and PWADI during split night studies;

To assess if any of the baseline HRV parameters (both time- and frequency-domain), delta heart rate (referred to as Delta HR), hypoxic burden, and pulse wave amplitude drop index (PWADI) or the change of these parameters may predict CPAP compliance;

To evaluate the minimum duration of quality data necessary for BR to achieve OSA diagnosis;

To examine the performance of OSA screening tools using OSA predictive AI models formulated by National Taiwan University Hospital (NTUH) and Northeast Ohio Medical University (NEOMED).

Panoramica dello studio

Stato

Attivo, non reclutante

Condizioni

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Stimato)

79

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Ohio
      • Chardon, Ohio, Stati Uniti, 44024
        • UH Geauga Health Center Services
      • Cleveland, Ohio, Stati Uniti, 44106
        • University Hospitals Cleveland Medical Center

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 80 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Provision of signed informed consent form.
  • Clinically assessed and suspicious for OSA with a STOP-Bang score ≥ 3.

Exclusion Criteria:

  • Full night PAP titration study.
  • On home O2, noninvasive ventilator, diaphragmatic pacing, or any form of a nerve stimulator.
  • Having atrial fibrillation-flutter, pacemaker/defibrillator, left ventricular assist device (LVAD), or status post cardiac transplantation.
  • Recent hospitalization or recent surgery in the past 30 days.
  • Unstable cardiopulmonary status on the night of the study judged to be unsafe for sleep study by the sleep tech and/or the on-call sleep physician.

If a participant did not sleep for at least 4 hours of technically valid sleep based on the Belun Ring method for diagnostic assessments, or a minimum of 3 hours of technically valid sleep during the diagnostic phase of a split-night study, the patient will be excluded from statistical analysis.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: UH-Participant

Potential participants will be identified from patients scheduled for in-lab PSG at the two medical centers of University Hospitals

The Belun Ring sensor should be placed on the palmar side of the proximal phalanx of the index finger and the sensor should be placed along the radial artery such that the accuracy of the device will be minimally affected by skin color. The Ring has 7 adjustable arms for different finger sizes. Each device is reusable after thorough cleaning with an alcohol swab.

The "Belun Cor" body sensor accessory is composed of an accelerometer, a temperature sensor, and a lithium battery. It will be placed immediately below the xiphoid process in the upper abdomen with a medical adhesive to detect the body temperature, body posture, respiratory rate, and respiratory efforts.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Performance of diagnosing sleep disordered breathing by BR's Gen3 DL algorithms
Lasso di tempo: 2 years

To establish mean, standard deviation, and target clinical agreement limit values for the differences in sleep-disordered breathing parameters (including AHI3%, AHI4%, REM AHI 3%, REM AHI4%, Supine AHI3%, Supine AHI4%, and CAI) from the BR against PSG. To calculate the sensitivity and specificity values, along with 95% confidence intervals (CIs), for sleep-disordered breathing parameters from the BR against PSG at PSG cutoffs of 5, 15, and 30 events/h. Pearson correlation and regression analysis will be employed to assess the association between sleep-disordered breathing parameters obtained from the BR and PSG.

2 years

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Performance of sleep stage classification by BR's Gen3 DL algorithms
Lasso di tempo: 2 years

Sensitivity and specificity of the Epoch-by-Epoch (EBE) 4-stage classification (wake, deep sleep, light sleep, REM) of the BR will be compared to EBE PSG data for each stage against the combination of the other three classifications. For instance, sensitivity for detecting wake will measure the proportion of correctly classified wake epochs against the combined classifications of deep sleep, light sleep, and REM sleep. Sensitivity and specificity values, accompanied by 95% CIs, of EBE body position (supine vs. non-supine) against PSG will also be computed.

2 years
To evaluate the minimum duration of quality data necessary for OSA diagnosis
Lasso di tempo: 2 years

To explore the minimum number of hours needed by the BR for an accurate OSA diagnosis, sensitivity, specificity, and Matthews Correlation Coefficient (MCC) values, along with 95% CIs, will be computed for sleep-disordered breathing parameters of Belun total record time (bTRT) and belun total sleep time (bTST) with different numbers of hours (e.g., 2, 3, 4, 5, 6, 7, and 8 hours) against PSG data. In cases where varying numbers of subjects meet different bTRT and bTST criteria at different durations, resampling methods like oversampling, undersampling, bootstrapping, etc., will be employed to address data imbalances.

2 years
Accuracy of the BR arrhythmia-detecting algorithm
Lasso di tempo: 3 years

To calculate the performance metrics, including sensitivity and specificity, along with 95% CIs, for the detection of arrhythmias by BR device in comparison to assessments made by a board-certified sleep physician. The physician will review the PSG ECG signals of the subjects suspected of having significant arrhythmias during the sleep study.

3 years
Biomarker relationship analysis
Lasso di tempo: 3 years

Pearson correlation and regression analysis will be employed: (1) to explore the relationships between autonomic nervous system (ANS) metrics and delta HR, hypoxic burden, and pulse wave amplitude drop index (PWADI); (2) to evaluate the association between HRV, Delta HR, hypoxic burden, PWADI, CPAP adherence, sleep-disordered breathing parameters, and demographic data (including age, gender, and BMI). If data distribution assumptions are violated, the Spearman correlation will be used instead of the Pearson correlation.

3 years
Accuracy of the NTUH and NEOMED models
Lasso di tempo: 3 years

The investigators will compute sensitivity and specificity values, accompanied by their respective 95% CIs, for AHI3% and AHI4% from the NTUH/NEOMED models in comparison to PSG. Furthermore, the investigators will determine the ROC curve at PSG-defined cutoffs of 5, 15, and 30 events/h for both AHI3% and AHI4%.

3 years

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Collaboratori

Investigatori

  • Investigatore principale: Ambrose A. Chiang, MD, University Hospitals Cleveland Medical Center
  • Investigatore principale: Susheel P. Patil, MD, University Hospitals Cleveland Medical Center
  • Investigatore principale: Kingman P. Strohl, MD, University Hospitals Cleveland Medical Center

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

19 luglio 2024

Completamento primario (Stimato)

31 dicembre 2026

Completamento dello studio (Stimato)

30 settembre 2027

Date di iscrizione allo studio

Primo inviato

15 gennaio 2024

Primo inviato che soddisfa i criteri di controllo qualità

2 febbraio 2024

Primo Inserito (Effettivo)

13 febbraio 2024

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

30 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

28 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • STUDY20231436

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .