Piattaforma per endoscopio monouso nelle procedure endoscopiche nel terzo spazio
Prova pilota prospettica per dimostrare l'efficacia, la fattibilità e la sicurezza di una piattaforma endoscopica monouso nelle procedure endoscopiche nel terzo spazio
This is a prospective, single-arm unblinded study performed at a single tertiary center in the United States. All subjects will receive standard medical care and no experimental interventions are going to be performed. The procedures will be performed by Dr. Mohamed Othman, Dr. Salmaan Jawaid, Dr. Tara Keihanian, and Dr. Fares Ayoub. All patients undergoing third space endoscopic procedures including e-POEM and g-POEM, meeting study inclusion criteria will be screened by study coordinators for preliminary eligibility and those who meet the inclusion criteria will be approached individually for further discussion about the study and obtaining informed consent.
The goal of this prospective, pilot trial is to demonstrate the efficacy, feasibility, safety, and clinical outcomes of third space endoscopic procedures completed using a disposable endoscope platform.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Over the past decade, therapeutic endoscopy has rapidly progressed giving rise to the fields of third space endoscopy and endoscopic surgery. In the foregut, esophageal per-oral endoscopic myotomy (e-POEM) has become the standard approach for achalasia with level I data supporting its use1. For gastroparesis, randomized clinical trial data 2 now supports gastric POEM (g-POEM) use for refractory cases with promising results particularly in diabetic and post-surgical patients.
Despite the remarkable advances in endoscopic therapy, there has been comparably slower progress in innovation for endoscopic platforms. In fact, current endoscope design is not significantly different from the earliest endoscopes where tip deflection is primarily controlled by rotating dials on the shaft of the endoscope and insufflation and suction are controlled by manual pressure-controlled buttons. Original fiberoptic gastroscopes were designed to facilitate diagnostic use, where the endoscopist manipulates tip-deflection dials using both hands while viewing the intestinal mucosa through a viewer, with an assistant moving the shaft of the endoscope. This same design was then adapted for colonoscopy, and later for duodenoscopy and endoscopic ultrasound. Despite significant progress in image quality, the endoscope remains a heavy device, requiring significant dexterity and musculoskeletal fitness on behalf of the endoscopist to perform endoscopy ergonomically without risking muscle injury. In addition, endoscopes require several supportive devices to function, including a separate water pump, video processor, computer screen and if needed an electrosurgical generator, making the portability of traditional endoscopic platforms quite limited.
More recently, rising concerns about infectious complications from reusable endoscopes have led to the development of several single-use endoscope platforms. A novel disposable endoscope (AMBU single-use disposable gastroscope; AMBU USA, Columbia, Md, USA) was recently approved by the U.S. Food & Drug Administration (FDA) in 2022 for use in humans. This endoscopic platform is designed for single use and comes with several advantages compared to traditional reusable endoscopes. The platform is significantly lighter, with a weight of 650 grams compared to a traditional reusable upper endoscope which weighs approximately 3900 grams. Additionally, the single use platform has a wider depth of field and significantly smaller video processor and built in portable screen. These advantages have led our group to use the endoscope for therapeutic foregut procedures including e-POEM and g-POEM with positive results. The investigators at Baylor College of Medicine most recently published a proof-of-concept experience 3 in using the disposable gastroscope for a case of e-POEM, where the significantly lighter weight of the endoscope allowed easier maneuverability and subjectively lower musculoskeletal strain for the performing endoscopist, with no negative effects on image quality or technical aspects of the procedure.
Before wider adoption, these perceived benefits need to be demonstrated in a larger, prospective trial confirming non-inferiority to historical data from reusable platforms and safety.
Tipo di studio
Tipo di studio
Contatti e Sedi
Luoghi di studio
-
-
Texas
-
Houston, Texas, Stati Uniti, 77030
- Baylor College of Medicine
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
All patients 18 years or older, not pregnant (if a woman), consenting to the study, and presents for an Esophageal POEM, or Gastric POEM will be invited to participate on this study.
Descrizione
Inclusion Criteria:
- Patient is ≥ 18 years old.
- Patients can provide informed consent.
- Patient is referred for third space endoscopic procedure including e-POEM, g-POEM.
Exclusion Criteria:
- Patient is < 18 years old.
- Patient refused and/or unable to provide consent.
- Patient is a pregnant woman.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: CASE_ONLY
- Prospettive temporali: PROSPECTIVE
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Technical Success
Lasso di tempo: Day 1 (procedure day)
|
Defined as the ability to perform entire myotomy (procedure) with the disposable endoscope. |
Day 1 (procedure day)
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Total Procedure Time
Lasso di tempo: During Procedure
|
Total recorded time to perform procedure using disposable endoscope |
During Procedure
|
|
Intraprocedural adverse events
Lasso di tempo: During Procedure
|
Adverse events emerging during procedure |
During Procedure
|
|
Satisfactory scores on Endoscopist satisfaction
Lasso di tempo: Immediately following completion of the procedure
|
Satisfactory survey: with endoscope maneuverability (1-5 Likert scale; 1 being "strongly disagree" to 5 being "strongly agree"), with endoscope functionality [insufflation, suction, accessory passage] (1-5 Likert scale), with endoscope image quality (1-5 Likert scale; 1 being "strongly disagree" to 5 being "strongly agree"). |
Immediately following completion of the procedure
|
|
Scores on musculoskeletal strain survey
Lasso di tempo: Immediately following completion of the procedure
|
Musculoskeletal Strain survey: Focused on Overall strain, wrist strain, shoulders strain, and neck strain |
Immediately following completion of the procedure
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Mohamed Othman, MD, Baylor College of Medicine
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- H-55176
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
There are no plans to share IPD to other researchers.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .