Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Stimolazione Acustica Durante il Sonno: Effetti sulla Memoria e sul p-tau217 nella MCI (PAS-MCI)

16 novembre 2026 aggiornato da: Farida Dakterzada, Institut de Recerca Biomèdica de Lleida-Fundació Dr. Pifarré (IRBLleida)

L'Impatto della Stimolazione Acustica a Fase Bloccata sulla Struttura del Sonno, sul Consolidamento della Memoria e sul p-tau217 Plasmatico in Pazienti con Deterioramento Cognitivo Lieve

The goal of this clinical trial is to determine whether acoustic stimulation during sleep can enhance slow-wave sleep (SWS), improve cognitive function, and reduce AD-related pathology in individuals with mild cognitive impairment (MCI), compared with cognitively healthy participants.

The main questions it aims to answer are:

  1. Does acoustic stimulation increase SWS (e.g., slow oscillation and sleep spindle activity) in individuals with MCI?
  2. Does enhancing SWS lead to improvements in memory and cognitive performance?
  3. Does acoustic stimulation influence plasma p-tau217 levels as a marker of underlying Alzheimer's disease pathology? Researchers will compare participants receiving acoustic stimulation during sleep with those not receiving stimulation to evaluate its effects on sleep architecture, cognition, and plasma biomarkers.

Participants will:

  • Undergo sleep recordings to assess sleep architecture, including SWS, slow oscillations, and sleep spindles
  • Receive acoustic stimulation during sleep across multiple nights
  • Complete cognitive assessments, particularly memory-related tasks
  • Provide blood samples to measure plasma p-tau217 levels
  • Provide clinical and demographic information for analysis

Panoramica dello studio

Stato

Non ancora reclutamento

Condizioni

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Stimato)

114

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Catalonia
      • Lleida, Catalonia, Spagna, 25198
        • Hospital Universitari Santa Maria de Lleida
        • Contatto:

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

60 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Diagnosis of aMCI according to the NIA-AA criteria (Albert et al., 2011) and positive state of plasma p-tau217.
  • Diagnosis of aMCI according to the NIA-AA criteria (Albert et al., 2011) and negative state of plasma p-tau217 for aMCI negative group.
  • Cognitively unimpaired older subjects aged ≥ 65 years, Mini-mental state examination ≥28, and negative for plasma p-tau217.

Exclusion Criteria:

  • Diagnosis of dementia due to AD or any other type of dementia.
  • Presence of any diagnosed sleep disorder such as narcolepsy, severe insomnia, severe obstructive sleep apnea, or severe chronic lack of sleep.
  • Hearing problems.
  • Analphabet individuals.
  • Comorbidities such as cancer, severe depression, severe renal or hepatic insufficiency, history of seizures, and severe cardiac or respiratory failure.
  • Alcohol and substance abuse.
  • Magnetic resonance imaging (MRI) evidence of stroke, hydrocephalus, a space-occupying lesion, or any clinically relevant central nervous system disease.
  • Existence of untreated (or treated for less than 3 months prior to the screening visit) vitamin B12 or folate deficiency.
  • Presence of untreated thyroid disease.
  • Use of betablockers, antidepressants, neuroleptics, and hypnotics, within 15 days before conducting polysomnography.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Altro
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Real-PLAS

Receiving phase-locked acoustic stimulation as an intervention

Participants will wear a mobile, wearable EEG device during sleep. Sleep will be recorded using EEG, and an algorithm will detect slow oscillations (SOs; >1 Hz). In the real-PLAS arm, acoustic stimulation will be applied in phase with the up-state of these slow oscillations. Specifically, the algorithm will detect each SO and trigger brief pink-noise bursts synchronized with the up-state phase, ensuring phase-locked acoustic stimulation (PLAS) is delivered precisely to enhance slow-wave activity.

Altri nomi:
  • Stimolazione acustica a circuito chiuso
  • Stimolazione uditiva a circuito chiuso
Comparatore fittizio: Sham-PLAS

Will have the same montage as real-PLAS, but no stimulation will be produced

Participants will have the same setup as in the real-PLAS arm, wearing a mobile, wearable EEG device during sleep. Sleep will be recorded using EEG, and an algorithm will detect slow oscillations (SOs; >1 Hz). No acoustic stimulation will be applied in the sham-PLAS arm.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Impact on SWS: SO and sleep spindle density
Lasso di tempo: 14 nights

Two defining features of slow-wave sleep (SWS) are slow oscillations (SO) and sleep spindles. Accordingly, the impact of multi-night PLAS on SWS in the study population will be evaluated by measuring the density of both features (expressed as counts per 30 seconds). Post-intervention measurements, including follow-up assessments, will be compared with the baseline night, during which no stimulation is applied, and with the sham group.

14 nights
Impact on SWS: SO and sleep spindle duration
Lasso di tempo: 14 nights

Two defining features of slow-wave sleep (SWS) are slow oscillations (SO) and sleep spindles. Accordingly, the impact of multi-night PLAS on SWS in the study population will be evaluated by measuring the duration of both features (expressed in seconds). Post-intervention measurements, including follow-up assessments, will be compared with the baseline night, during which no stimulation is applied, and with the sham group.

14 nights
Impact on SWS: SO and sleep spindle peak-to-peak amplitude
Lasso di tempo: 14 nights

Two defining features of slow-wave sleep (SWS) are slow oscillations (SO) and sleep spindles. Accordingly, the impact of multi-night PLAS on SWS in the study population will be evaluated by measuring the peak-to-peak amplitude of both features (expressed in µV).Post-intervention measurements, including follow-up assessments, will be compared with the baseline night, during which no stimulation is applied, and with the sham group.

14 nights
Impact on SWS: SO and sleep spindle peak power frequency
Lasso di tempo: 14 nights

Two defining features of slow-wave sleep (SWS) are slow oscillations (SO) and sleep spindles. Accordingly, the impact of multi-night PLAS on SWS in the study population will be evaluated by measuring the peak power frequency of each feature (expressed in Hz). Post-intervention measurements, including follow-up assessments, will be compared with the baseline night, during which no stimulation is applied, and with the sham group.

14 nights
Impact on SWS: SO and sleep spindle power
Lasso di tempo: 14 nights

Two defining features of slow-wave sleep (SWS) are slow oscillations (SO) and sleep spindles. Accordingly, the impact of multi-night PLAS on SWS in the study population will be evaluated by measuring the power of both features (expressed in µV2). Post-intervention measurements, including follow-up assessments, will be compared with the baseline night, during which no stimulation is applied, and with the sham group.

14 nights
Impact on declarative memory consolidation: correct performance in the Verbal Paired Associates test
Lasso di tempo: Up to 3 months after intervention

The impact of multi-night PLAS on declarative memory performance in the study population will be assessed using the Verbal Paired Associates (VPA) test. Performance will be quantified as the number of correctly recalled word pairs. Post-intervention measurements, including follow-up assessments, will be compared with the first recall, conducted in the morning after the baseline night, and with the sham group.

Up to 3 months after intervention
Impact on procedural memory consolidation: correct performance in the Motor Sequence Typing task
Lasso di tempo: Up to 3 months after intervention

The impact of multi-night PLAS on procedural memory performance in the study population will be assessed using the Motor Sequence Typing task (MST). Performance will be quantified as the number of correctly executed sequences (i.e., keypresses) per trial. Post-intervention measurements, including follow-up assessments, will be compared with the first recall, conducted in the morning after the baseline night, and with the sham group.

Up to 3 months after intervention
Impact on procedural memory consolidation: incorrect performance in the Motor Sequence Typing task
Lasso di tempo: Up to 3 months after intervention

The impact of multi-night PLAS on procedural memory performance in the study population will be assessed using the Motor Sequence Typing task (MST). Performance will be quantified as the number of incorrectly executed sequences (i.e., keypresses) per trial. Post-intervention measurements, including follow-up assessments, will be compared with the first recall, conducted in the morning after the baseline night, and with the sham group.

Up to 3 months after intervention
Impact on procedural memory consolidation: total attempt performance in the Motor Sequence Typing task
Lasso di tempo: Up to 3 months after intervention

The impact of multi-night PLAS on procedural memory performance in the study population will be assessed using the Motor Sequence Typing Task (MST). Performance will be quantified as the total number of executed sequences (i.e., keypresses) per trial. Post-intervention measurements, including follow-up assessments, will be compared with the first recall, conducted in the morning after the baseline night, and with the sham group.

Up to 3 months after intervention
Impact on p-tau217
Lasso di tempo: Up to 3 months after intervention

Post-intervention plasma levels of p-tau217(pg/mL), including follow-up assessments, will be measured in the study population and compared with baseline values as well as with the sham group.

Up to 3 months after intervention

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Effect on GFAP and NfL
Lasso di tempo: Up to 3 months after intervention

Post-intervention plasma levels of Glial fibrillary acidic protein (GFAP, pg/mL) and neurofilament light (NfL, pg/mL), including follow-up assessments, will be measured in the study population and compared with baseline values as well as with the sham group.

Up to 3 months after intervention

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 dicembre 2026

Completamento primario (Stimato)

1 dicembre 2027

Completamento dello studio (Stimato)

1 dicembre 2028

Date di iscrizione allo studio

Primo inviato

18 marzo 2026

Primo inviato che soddisfa i criteri di controllo qualità

7 aprile 2026

Primo Inserito (Effettivo)

14 aprile 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

19 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

16 novembre 2026

Ultimo verificato

1 aprile 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • PI25/01702

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .