Dual Energy Focal Ablation of Premature Ventricular Complexes (DUAL-PVC)
Dual Energy (RF/PF) Focal Ablation of Premature Ventricular Complexes: the DUAL-PVC Prospective Clinical Trial
The purpose of this research is to understand whether a dual-energy catheter ablation system that uses radiofrequency (RF) and pulsed-field (PF) energy can safely and effectively treat premature ventricular contractions (PVCs).
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Konstantinos Siontis, MD
- Numero di telefono: 507-255-0774
- Email: siontis.konstantinos@mayo.edu
Luoghi di studio
-
-
Minnesota
-
Rochester, Minnesota, Stati Uniti, 55905
- Mayo Clinic
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
-
≥10% burden of the target PVC on ambulatory rhythm monitoring within 3 months prior to enrollment. The qualifying ambulatory monitor may be of any duration (1-30 days) per standard of care and may be distinct from the baseline 12-lead Holter required within 30 days before ablation
-
Guideline-supported indication for first-time or redo catheter ablation of PVCs at the judgment of the electrophysiologist. Specifically:
- Patients with symptomatic PVCs for whom antiarrhythmic medications are ineffective, not tolerated, or not the patient's preference.
- Suspected or confirmed PVC-induced cardiomyopathy
- Enrollment of patients requiring a redo procedure will be capped at 30% of planned enrollment (n=18) if the target PVC is the same or similar to that targeted in previous procedure(s), per review of the study investigator
-
Patients with and without known structural heart disease are eligible
-
Ability to undergo study-directed cardiac MRI pre- and post-procedure
-
Ability to undergo study-directed post-ablation coronary CT angiography
-
Ability to provide written informed consent
Exclusion Criteria:
- LVEF <35%
- NYHA class IV
- Presence of multifocal PVCs (>=3 distinct morphologies) on available pre-baseline standard-of-care ambulatory monitor and ECG tracings per the review of the study team.
- PVCs attributable to a reversible or non-cardiac cause (e.g., electrolyte imbalance or active thyroid disease).
- History of sustained VT or VF.
- Current or recent (<4 weeks) decompensated heart failure.
- Active systemic infection.
- Contraindication to LGE-MRI or contrast CT.
- Known allergy to iodinated contrast dye that cannot be adequately managed with pre-medication protocol.
- Thrombocytopenia (platelet count <50,000/mm³) or known coagulopathy.
- Contraindication to systemic anticoagulation.
- Severe valvular disease requiring future intervention.
- Mechanical valve prosthesis.
- Pregnancy.
- Recent acute coronary syndrome (<6 months).
- Un-revascularized coronary artery disease.
- Presence of left ventricular assist device (LVAD) or transplanted heart.
- Presence of intracardiac thrombus.
- Current use of inotropes.
- Recent stroke or TIA (<6 months).
- Presence of a systemic illness likely to limit survival to <1 year.
- Patient enrollment in other clinical study that could conflict with the current investigation.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: RF-PF Sequential Ablation
Participants are assigned to receive radiofrequency (RF) followed by pulsed-field (PF) at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location. |
The THERMOCOOL SMARTTOUCH™ SF Bi-Directional Navigation Catheter is an irrigated, contact-force-sensing catheter used to map the heart and deliver radiofrequency (RF) or pulsed-field (PF) energy to selected treatment sites. The catheter is connected to the TRUPULSE™ Generator, which provides both energy types, and to the nGEN™ Pump, which controls saline irrigation. The system is used with the CARTO™ 3 electroanatomic mapping system and workstation with the VISITAG SURPOINT™ Module to display heart anatomy, catheter location, catheter-to-tissue contact, and treatment information during the procedure. |
|
Sperimentale: PF-Only Ablation
Participants are assigned to receive pulsed-field (PF) alone at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location. |
The THERMOCOOL SMARTTOUCH™ SF Bi-Directional Navigation Catheter is an irrigated, contact-force-sensing catheter used to map the heart and deliver radiofrequency (RF) or pulsed-field (PF) energy to selected treatment sites. The catheter is connected to the TRUPULSE™ Generator, which provides both energy types, and to the nGEN™ Pump, which controls saline irrigation. The system is used with the CARTO™ 3 electroanatomic mapping system and workstation with the VISITAG SURPOINT™ Module to display heart anatomy, catheter location, catheter-to-tissue contact, and treatment information during the procedure. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Number of Participants With Successful Delivery of Ablation Lesions Using the Dual-Energy THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator
Lasso di tempo: During the index ablation procedure
|
Feasibility is defined as successful delivery of ablation energy at the targeted premature ventricular complex (PVC) site. Delivery counts as successful only if there is no study device deficiency or malfunction that prevents energy delivery, and no need to convert to a bailout ablation approach. |
During the index ablation procedure
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Acute procedural success
Lasso di tempo: End of the ablation procedure
|
Number of participants with elimination of the target premature ventricular contraction by the end of the procedure. |
End of the ablation procedure
|
|
Participants with greater than 80% reduction in target PVC burden
Lasso di tempo: 1 month, 6 months
|
Number of participants with greater than 80% reduction from baseline in the burden of the target premature ventricular contraction on Holter monitoring. |
1 month, 6 months
|
|
Change in Short Form Health Survey (SF-36) score
Lasso di tempo: Baseline, 1 month, 6 months
|
The 36-Item Short Form Health Survey (SF-36) is a participant-reported questionnaire that assesses health-related quality of life across eight domains: physical functioning, role limitations due to physical health, bodily pain, general health, vitality, social functioning, role limitations due to emotional problems, and mental health. Total scores range from 0 to 100. Higher scores indicate better health status. |
Baseline, 1 month, 6 months
|
|
Change in EQ-5D score
Lasso di tempo: Baseline, 1 month, 6 months
|
The EQ-5D is a participant-reported measure of health-related quality of life covering five dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. Responses across the five dimensions define the participant's health state. Higher scores indicate better health. |
Baseline, 1 month, 6 months
|
|
Number of Participants With New Coronary Artery Stenosis on Coronary CT Angiography at 6 Months After Ablation
Lasso di tempo: 6 months
|
Total number of patients with new-onset coronary luminal stenosis found on CT coronary angiography |
6 months
|
|
Total Procedure Time
Lasso di tempo: From start to finish of index ablation procedure
|
Total procedure time will be reported in minutes |
From start to finish of index ablation procedure
|
|
Electrogram endpoints
Lasso di tempo: Intraprocedure
|
EGM amplitude changes after PF, RF, and RF-PF lesion delivery |
Intraprocedure
|
|
Ablation Lesion Depth
Lasso di tempo: 1 month and 6 months after ablation
|
Maximum depth of the ablation lesion at the target premature ventricular complex (PVC) site. Depth is measured from the endocardial surface on late gadolinium enhancement (LGE) cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters. |
1 month and 6 months after ablation
|
|
Ablation Lesion Width
Lasso di tempo: 1 month and 6 months after ablation
|
Maximum width of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters. |
1 month and 6 months after ablation
|
|
Ablation Lesion Volume
Lasso di tempo: 1 month and 6 months after ablation
|
Total volume of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in cubic centimeters. |
1 month and 6 months after ablation
|
|
Number of Radiofrequency (RF) Lesions Delivered per Participant
Lasso di tempo: During the index ablation procedure
|
Total number of RF lesions delivered with the study catheter during the index procedure |
During the index ablation procedure
|
|
Number of Pulsed-Field (PF) Lesions Delivered per Participant
Lasso di tempo: During the index ablation procedure
|
Total number of PF lesions delivered with the study catheter during the index procedure |
During the index ablation procedure
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Konstantinos Siontis, MD, Mayo Clinic
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 25-013930
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .