The goal of this clinical trial is to document corneal ectasia stability in patients with keratoconus diagnosis treated with personalized cross linking energy. The main questions it aims to answer are:
- Is it effective while using personalized (reduced) energy?
- Is it safe for corneas thinner than 400 microns? Participants will be treated with personalized energy corneal cross linking and posteriorly, will attend subsequent follow-up consults
Panoramica dello studio
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Mexico City, Messico
- Instituto de Oftalmología Conde de Valenciana
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Keratoconus diagnosed with corneal tomography/topography
- Thinnest point pachymetry below 400 microns
Exclusion Criteria:
- Previous corneal cross linking history
- Corneal scars not allowing best corrected visual acuity of 20/100 or better
- Previous corneal hydrops history
- Psychomotor retardation history
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Personalized cross linking
Participants were treated with personalized energy cross linking according to their thinnest point corneal pachymetry |
Total fluence adapted to thinnest point pachymetry |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Keratometry stability
Lasso di tempo: Baseline and 6 months
|
Stability documented by changes in keratometries (measured in diopters) obtained with corneal tomography, as well as uncorrected visual acuity observed in follow up consults |
Baseline and 6 months
|
|
Pachymetry stability
Lasso di tempo: Baseline and 6 months
|
Stability documented by changes in pachymetry (measured in microns) obtained with corneal tomography |
Baseline and 6 months
|
|
Uncorrected visual acuity stability
Lasso di tempo: Baseline, 72 hours, 1 week, 3 months and 6 months
|
Stability documented by changes in uncorrected visual acuity (measured in logarithm of the minimum angle of resolution) obtained on physical examiantion |
Baseline, 72 hours, 1 week, 3 months and 6 months
|
|
Corneal endothelium safety
Lasso di tempo: Baseline, 72 hours, 1 week, 3 months and 6 months
|
Corneal endothelial cell count obtained by specular microscopy |
Baseline, 72 hours, 1 week, 3 months and 6 months
|
Collaboratori e investigatori
Investigatori
- Direttore dello studio: Enrique Graue, MD, MSc, Instituto de Oftalmología Conde de Valenciana
Pubblicazioni e link utili
Pubblicazioni generali
- Hafezi F, Kling S, Gilardoni F, Hafezi N, Hillen M, Abrishamchi R, Gomes JAP, Mazzotta C, Randleman JB, Torres-Netto EA. Individualized Corneal Cross-linking With Riboflavin and UV-A in Ultrathin Corneas: The Sub400 Protocol. Am J Ophthalmol. 2021 Apr;224:133-142. doi: 10.1016/j.ajo.2020.12.011. Epub 2021 Jan 30.
- Lang PZ, Hafezi NL, Khandelwal SS, Torres-Netto EA, Hafezi F, Randleman JB. Comparative Functional Outcomes After Corneal Crosslinking Using Standard, Accelerated, and Accelerated With Higher Total Fluence Protocols. Cornea. 2019 Apr;38(4):433-441. doi: 10.1097/ICO.0000000000001878.
- Nath S, Shen C, Koziarz A, Banfield L, Nowrouzi-Kia B, Fava MA, Hodge WG. Transepithelial versus Epithelium-off Corneal Collagen Cross-linking for Corneal Ectasia: A Systematic Review and Meta-analysis. Ophthalmology. 2021 Aug;128(8):1150-1160. doi: 10.1016/j.ophtha.2020.12.023. Epub 2020 Dec 28.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 17 CI 09 015 008
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .