Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Evaluating Percutaneous Repair Of The Atrial Septum With A Novel PFO Occluder: The PROTEA-PFO OUS Study (PROTEA-PFO OUS)

7 luglio 2026 aggiornato da: Recross Cardio, Inc.

The goal of this clinical trial is to test a new heart device called P3 Occluder System in patients who have a small opening between the upper chambers of the heart (called a Patent Foramen Ovale or PFO) and have experienced a stroke that may be related to this heart opening. The main question it aims to answer is:

• Is the P3 Occluder System safe and effective for closing a PFO in patients who have had a stroke that could be related to a PFO.

Participants will:

  • Undergo the procedure to implant the P3 Occluder System, if deemed appropriate.
  • Visit their doctor at 1 month, 3 months, 6 months, and 1 year after the procedure for follow up exams.
  • Answer a phone call from study staff at 2 years and 3 years after the procedure to answer a survey.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Stimato)

15

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Luoghi di studio

      • Belgrade, Serbia
        • Reclutamento
        • Institute for cardiovascular diseases ''Dedinje'', Belgrade
        • Contatto:

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  1. Patient must be ≥ 18 and ≤ 65 years of age
  2. Diagnosis of PFO, defined as visualization of microbubbles per TEE in the left atrium within three cardiac cycles from the right atrial opacification demonstrating right-to-left shunting at rest and/or during Valsalva release.
  3. Ischemic stroke, defined as acute focal neurological deficit, presumed to be due to focal ischemia and confirmed by MRI or CT to have a neuroanatomically relevant cerebral infarct.
  4. Modified Rankin score (mRS) ≤ 3.
  5. Appropriate PFO anatomy for implantation of the investigational device as evaluated and determined by independent committee.
  6. Patient is willing and capable of providing informed consent.
  7. Prior to index procedure (7-day window), persons of childbearing potential must have a negative pregnancy test.

Exclusion Criteria:

  1. Other identifiable causes of stroke, including but not limited to aortic arch plaques (protruding >4 mm into the lumen), large artery atherosclerotic disease proximal to the territory of the index stroke, an established cardioembolic source, small-vessel occlusive disease, or arterial dissection, presence of left atrial appendage thrombus.
  2. Other arteriopathy of the intracranial or extracranial vessels with >50% stenosis proximal to the territory of the index stroke.
  3. Intracardiac thrombus or tumor.
  4. Myocardial Infarction (MI) or unstable angina within the previous 180 days.
  5. Life expectancy < 2 years.
  6. Left ventricular aneurysm or akinesis.
  7. Moderate to severe mitral valve stenosis or severe mitral regurgitation.
  8. Aortic valve stenosis (mean gradient >20 mmHg) or severe regurgitation.
  9. Active endocarditis or other infection that may preclude implantation of the investigational device.
  10. Any valve vegetation or Lambl's excrescence of any left-sided valve.
  11. Left ventricular dilated cardiomyopathy with LVEF <35%.
  12. Another source of right-to-left shunts identified at baseline, including an atrial septal defect and/or fenestrated septum and pulmonary arteriovenous malformation.
  13. History of atrial tachycardia, atrial fibrillation or flutter, AV block, or ventricular arrhythmia requiring antiarrhythmic medication, pacemaker, or AICD.
  14. Severe renal failure ( Stage 4 CKD, eGFR <30) or patient requiring dialysis.
  15. Severe liver disease (e.g., documented cirrhosis or active hepatitis).
  16. Severe lung insufficiency (e.g., need for supplemental oxygen or chronic steroid medications).
  17. Uncontrolled hypertension, defined as sustained elevated blood pressure >140/90 mm Hg.
  18. Severe pulmonary artery hypertension, defined as pulmonary systolic pressure of >50mmHg.
  19. Uncontrolled hyperglycemia, defined as HbA1c value >8% (IFCC: >64 mmol/mol).
  20. Increased bleeding risk such as severe liver failure, active peptic ulcer, proliferative diabetic retinopathy, history of severe bleeding (e.g.: gastrointestinal bleeding, macroscopic hematuria, intraocular bleeding, intracranial or cerebral hemorrhage), or other history of bleeding or coagulopathy.
  21. Known hypercoagulable state that would require full anticoagulation. Minimum testing to include lupus anticoagulant, anticardiolipin antibodies, beta-2-glycoprotein, homocysteine.
  22. Subjects contraindicated for aspirin or clopidogrel.
  23. Subjects not able to discontinue anticoagulation for indications other than then index stroke.
  24. Any disorder in the investigator's opinion that could interfere with compliance of safety evaluation or require premature discontinuation of antiplatelet regime post-implantation, as well as any severe concurrent illness that would limit life expectancy (e.g., malignancies).
  25. Currently an active subject in an investigational drug or device study that could confound the results of this study.
  26. Any significant valve dysfunction that contraindicates PFO closure or increased pulmonary vascular resistance/severe pulmonary hypertension.
  27. Contraindication for transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE).
  28. Any prior percutaneous cardiovascular intervention for AF ablation.
  29. Known nickel allergy that, in the opinion of the investigator, poses a safety risk with regards to participation in the trial.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Fattibilità del dispositivo
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Sistema Occluder P3 RECross (P3O)
L'occluder P3 RECRAC (P3O) è in fase di sviluppo ai fini della chiusura del trancatetere di un forame di brevetto ovale (PFO) per ridurre il rischio di ictus ischemico ricorrente nei pazienti con ictus associato a PFO.
L'occluder P3 RECRAC (P3O) è in fase di sviluppo ai fini della chiusura del trancatetere di un forame di brevetto ovale (PFO) per ridurre il rischio di ictus ischemico ricorrente nei pazienti con ictus associato a PFO.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Effective PFO Closure
Lasso di tempo: 6 months
Effective PFO Closure, at index procedure and at 6 months as measured by TEE, as adjudicated.
6 months
Adverse Cardiovascular Events
Lasso di tempo: 30 days
Occurrence of significant adverse events including cardiac death, myocardial infarction, and stroke within 30 days post-procedure
30 days

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Rate of device-related or procedure-related Serious Adverse Events (SAEs)
Lasso di tempo: 30 days; 6 months
Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 30 days. Rate of device-related or procedure-related Serious Adverse Events (SAEs) at 6 months.
30 days; 6 months
Correct device position
Lasso di tempo: 6 months
Correct device position as assessed at 6 months on echocardiography, assessed by TTE or TEE.
6 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

17 giugno 2026

Completamento primario (Stimato)

1 luglio 2027

Completamento dello studio (Stimato)

1 dicembre 2029

Date di iscrizione allo studio

Primo inviato

15 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

7 luglio 2026

Primo Inserito (Effettivo)

13 luglio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 luglio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

7 luglio 2026

Ultimo verificato

1 luglio 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Forame ovale pervio

Prove cliniche su Sistema Occluder P3 RECross (P3O)

3
Sottoscrivi