小児集中治療室で挿管された小児における心エコー検査による中心静脈圧の推定 (PVCECHO)
小児集中治療中の挿管された小児における心エコー検査による中心静脈圧の推定:前向き多施設共同研究
Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.
The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.
When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.
The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.
The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.
調査の概要
状態
詳細な説明
Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.
The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.
When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.
The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.
The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Paris、フランス、75019
- Robert Debre Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Intubated pediatric patients in an PICU
説明
Inclusion Criteria:
- Newborns and children from 2 days post term to 12 years Mechanical ventilation
- Carriers of a central venous catheter in the superior vena cava and ending in the right atrium"
Exclusion Criteria:
-
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:PROSPECTIVE
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The correlation between the measurement of the Collapsibility Index, the Distensibility Index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the Abdominal Aorta with the measurement of the CVP.
時間枠:1 day
|
Correlation coefficient value between CI, DI, and IVC dmax /AO measurements and reference method CVP measurement |
1 day
|
協力者と研究者
捜査官
- 主任研究者:Perrine SEE, MD、Assistace Publique Hopitaux de Paris
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- APHP21
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。