Estimativa da Pressão Venosa Central por Ecocardiografia em Crianças Intubadas em Terapia Intensiva Pediátrica (PVCECHO)

4 de novembro de 2026 atualizado por: Assistance Publique - Hôpitaux de Paris

Estimativa da Pressão Venosa Central por Ecocardiografia em Crianças Intubadas em Terapia Intensiva Pediátrica: um Estudo Multicêntrico Prospectivo

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.

The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.

When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.

The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.

The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.

Visão geral do estudo

Descrição detalhada

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU.

The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP.

When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies.

The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time.

The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.

Tipo de estudo

Observacional

Inscrição (Real)

120

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Paris, França, 75019
        • Robert Debre Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

2 dias a 12 anos (Filho)

Aceita Voluntários Saudáveis

N/D

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Intubated pediatric patients in an PICU

Descrição

Inclusion Criteria:

  • Newborns and children from 2 days post term to 12 years Mechanical ventilation
  • Carriers of a central venous catheter in the superior vena cava and ending in the right atrium"

Exclusion Criteria:

-

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: PROSPECTIVE

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
The correlation between the measurement of the Collapsibility Index, the Distensibility Index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the Abdominal Aorta with the measurement of the CVP.
Prazo: 1 day

Correlation coefficient value between CI, DI, and IVC dmax /AO measurements and reference method CVP measurement

1 day

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Perrine SEE, MD, Assistace Publique Hopitaux de Paris

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

3 de novembro de 2021

Conclusão Primária (Real)

3 de novembro de 2022

Conclusão do estudo (Real)

3 de novembro de 2022

Datas de inscrição no estudo

Enviado pela primeira vez

4 de janeiro de 2022

Enviado pela primeira vez que atendeu aos critérios de CQ

4 de janeiro de 2022

Primeira postagem (Real)

19 de janeiro de 2022

Atualizações de registro de estudo

Última Atualização Postada (Real)

6 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

4 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • APHP21

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever