AR ベースのニューロナビゲーション システムの検証のための臨床試験
Exploratory Clinical Trial for the Evaluation of the Accuracy of Augmented Reality-Based Neuronavigation System
The goal of this clinical trial is to test augmented reality (AR) based neuronavigation system in surgeries for patients of brain neoplasm or cerebral vascular disease. The main questions it aims to answer are:
• AR based neuronavigation system can achieve accuracy that is not inferior to conventional intraoperative navigation system.
Participants will participate the study after informed consent. When participants undergo surgery for their brain tumor, we will set up 2 types of neuronavigation, conventional navigation system and developed AR based neuronavigation system. Surgeon will plan and conduct surgery based on only conventional navigation system, but 3D errors at several selected points between two types of navigation will be measured and analyzed.
調査の概要
詳細な説明
Being developed AR navigation were reported in our following papers:
- Dho YS, et al., Development of an inside-out augmented reality technique for neurosurgical navigation. Neurosurgical Focus. 2021 Aug 1;51(2):E21. (doi.org/10.3171/2021.5.FOCUS21184)
- Moon HC, et al., Navigation of frameless fixation for gamma knife radiosurgery using fixed augmented reality. Scientific Reports. 2022 Mar 16;12(1):1-0. (doi.org/10.3171/2021.5.FOCUS21184)
This study aims to evaluate the accuracy of anatomical localization of a newly developed augmented reality-based neurosurgery navigation. After 3-dimensional (3D) modeling of the brain of a patient with brain tumor or cerebral vascular disease through 3D image segmentation extraction and modeling, the Augmented Reality (AR)-based navigation developed by this research team can be used with a commercially available visualization device, such as iPad, iPhone, and Hololens2, to evaluate the accuracy.
The AR-based navigation obtained approval from the Ministry of Food and Drug Safety of Republic of Korea (class 2 medical device) in February 2022. Through this clinical tria that compare accuracy with existing conventional intraoperative neuronavigation system, we will evaluate whether it shows equivalent performance to replace the existing navigation.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Chul-Kee Park, MD, PhD
- 電話番号:+82220720347
- メール:nsckpark@snu.ac.kr
研究連絡先のバックアップ
- 名前:Sun Mo Nam, MD
- 電話番号:+82020722357
- メール:md.nsm.ns@gmail.com
研究場所
-
-
-
Seoul、韓国、03080
- 募集
- Seoul National University Hospital
-
コンタクト:
- Sun Mo Nam, MD
- 電話番号:8220722357
- メール:md.nsm.ns@gmail.com
-
副調査官:
- Yun-Sik Dho, MD, PhD
-
-
Seoul
-
Seoul、Seoul、韓国、03080
- まだ募集していません
- Seoul National University Hospital
-
コンタクト:
- Chul-Kee Park, MD, PhD
- 電話番号:+82220720347
- メール:nsckpark@snu.ac.kr
-
コンタクト:
- Sun Mo Nam, MD
- 電話番号:+821096713692
- メール:md.nsm.ns@gmail.com
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults aged 18 years or older with a brain tumor or cerebrovascular disease who have undergone preoperative CT
- Scheduled for surgical treatment of the brain tumor or cerebrovascular disease
- Surgical position allowing exposure and measurement of bilateral Kocher's points and the glabella without significant head rotation
Exclusion Criteria:
- Patient or legal representative does not consent to participation, including consent to intraoperative video recording
- Anatomical deformity of the skull or facial region due to previous surgery or other causes that precludes identification of Kocher's points or the glabella
- Emergency surgery
- Surgical position (e.g., prone, lateral rotation of 90° or more) that does not allow simultaneous exposure of bilateral Kocher's points and the glabella
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Single arm
We will set up 2 navigation systems, newly developed AR-based navigation and conventional navigation system, to surgeries of all participants. Surgeons will perform all surgical planning and operations with reference to the conventional navigation system. In this process, the errors of the existing navigation and the newly developed navigation will be measured and compared in 3D at several points, and the points are as follows:
|
Patient-specific 3D models are generated from preoperative CT using MEDIP PRO and displayed on a tablet (iPad) via MEDIP PRO AR, superimposed on the patient using markerless surface registration. Registration and TRE measurement are video-recorded for retrospective analysis of registration time. The device is used for accuracy evaluation only and does not guide any surgical step. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Target Registration Error (TRE) of AR-based navigation at anatomical landmarks
時間枠:Intraoperative, immediately after AR registration before surgical draping on the day of surgery
|
Linear distance (mm) between the landmark position displayed by MEDIP PRO AR and the actual position on the patient's skin/skull surface, measured directly with a ruler at three fixed landmarks per participant (right Kocher's point, left Kocher's point, glabella). Measured immediately after registration (pre-drape). Reported as mean ± SD or median (IQR) overall and per landmark. |
Intraoperative, immediately after AR registration before surgical draping on the day of surgery
|
|
Registration time of AR-based navigation
時間枠:Intraoperative, on the day of surgery
|
Time (minutes, seconds) from AR software launch to completion of registration, determined by retrospective analysis of intraoperative video recording. Reported separately for manual and automatic registration. |
Intraoperative, on the day of surgery
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Post-drape TRE after QR marker-based registration restoration
時間枠:Intraoperative, immediately after draping, on the day of surgery
|
TRE (mm) at the same three landmarks measured after surgical draping and restoration of registration using QR markers attached to the skin. |
Intraoperative, immediately after draping, on the day of surgery
|
|
Incidence of registration drift after draping
時間枠:Intraoperative, immediately after draping, on the day of surgery
|
Proportion of landmarks showing visible displacement of the AR overlay of ≥7.5 mm after draping, assessed on a second tablet held in a fixed mount. |
Intraoperative, immediately after draping, on the day of surgery
|
|
Adverse events and device malfunctions
時間枠:Intraoperative through end of surgery, on the day of surgery
|
Number and description of adverse events and device errors occurring during AR navigation application. |
Intraoperative through end of surgery, on the day of surgery
|
|
One-step processing time from CT acquisition to 3D model delivery (SNUH only)
時間枠:Preoperative, within 24 hours before surgery
|
Total elapsed time from CT image receipt on the server to delivery of the 3D mesh to the tablet, including automatic segmentation, calculated from system log timestamps. Success of automatic segmentation (no manual correction required) is also recorded. |
Preoperative, within 24 hours before surgery
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- 2204-094-1317
- 202012E08 (その他の助成金/資金番号:Korea Medical Device)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。