このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

複雑冠動脈病変におけるInspiron EVO薬剤溶出ステントのブラジル前向きレジストリ (PCI EVOlution)

2026年10月1日 更新者:Scitech Produtos Medicos SA

複雑冠動脈病変におけるInspiron EVO薬剤溶出ステント全国前向きレジストリ

The objective is to evaluate the efficacy and safety of the Inspiron™ EVO drug-eluting stent in complex coronary lesions in a real-world population. Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions will be treated with the Inspiron™ EVO drug-eluting stent.

調査の概要

詳細な説明

Post-marketing, observational, prospective, multi-center, non-randomized, single-arm registry that will include all patients who receive the Inspiron™ EVO stent at participating sites and meet the eligibility criteria.

Up to 2,000 patients are expected to be enrolled across 12 research sites in Brazil. Participants' demographic, procedural, and follow-up data will be collected for up to 12 months in this study.

研究の種類

観察的

入学 (推定)

2000

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

    • Rio Grande do Sul
      • Porto Alegre、Rio Grande do Sul、ブラジル、90610000
        • 募集
        • Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
        • コンタクト:
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions treated with the Inspiron™ EVO Drug-Eluting Stent.

説明

Inclusion Criteria:

  • Individuals aged 18 years or older presenting with complex coronary lesions requiring percutaneous coronary intervention (PCI).
  • Individuals who provide consent and are willing to comply with the follow-up protocol.
  • Individuals who received treatment with the Inspiron™ EVO Stent.
  • Individuals with lesions ≥ 30 mm in length (Subprotocol 1).
  • Individuals with significantly calcified coronary lesions (moderate to severe according to the ACC/AHA classification B1, B2, or C), with or without indication for lesion preparation techniques (Subprotocol 2).
  • Individuals with multivessel coronary artery disease (≥2 affected coronary vessels, with at least one vessel of small diameter ≤2.5 mm) (Subprotocol 3).
  • Individuals included in Subprotocol 1, 2, or 3. The evaluated segment must be accessible to the IVUS (Intravascular Ultrasound) catheter (Subprotocol 4).

Exclusion Criteria:

  • Lesions in saphenous vein grafts or internal mammary grafts.
  • Contraindication to the use of a drug-eluting stent.
  • Individuals who were treated during the index procedure with any stent other than the Inspiron™ EVO Stent.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:COHORT
  • 時間の展望:PROSPECTIVE

コホートと介入

グループ/コホート
介入・治療
Experimental: Percutaneous coronary intervention (PCI)

Patients with symptomatic ischemic heart disease due to lesions in the native coronary artery and restenotic lesions treated with the Inspiron™ EVO drug-eluting stent.

Percutaneous coronary intervention (PCI) using the Inspiron EVO Drug-Eluting Stent, which has a reduced crimped profile, providing greater safety and facilitating lesion crossing. In addition, the design is optimized to provide increased radial strength.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Device success
時間枠:Initial procedure

Device success (at the lesion level) is defined as the successful delivery, balloon expansion, and implantation of the first device at the target lesion (with multiple attempts using the same device permitted), successful withdrawal of the delivery system, and achievement of a final in-stent residual stenosis of <20%

Initial procedure
Acute Clinical Success of Percutaneous Coronary Intervention (PCI)
時間枠:Up to 24 hours

Defined as the absence of major adverse in-hospital cardiac events (death, myocardial infarction, or repeat coronary revascularization of the target lesion).

Up to 24 hours
MACE (Major Adverse Cardiac Events) rate
時間枠:12 months

Defined as the combination of cardiac death, myocardial infarction (MI), or revascularization of the target lesion (TLR).

12 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Target Lesion Revascularization (TLR) rate
時間枠:12 months

TLR is defined as any percutaneous reintervention of the target lesion, including the 5 mm proximal and 5 mm distal segments of the stent, or revascularization of the target vessel, performed for clinical reasons due to restenosis or occlusion of the target lesion.

12 months
Target vessel revascularization rate (TVR)
時間枠:12 months

TVR is defined as revascularization of any segment of the target coronary artery.

12 months
Target Vessel Failure Rate (TVF)
時間枠:12 months

Defined as a combination of MI, TLR, or cardiovascular death related to the target vessel. If it is not possible to determine with certainty whether the MI or death was related to the target vessel, the case is considered a TVF.

12 months
Rate of definite, probable, and possible stent thrombosis (ST)
時間枠:12 months

Stent thrombosis is classified as definite, probable, or possible: definite requires angiographic or pathological confirmation; probable includes unexplained death within 30 days or myocardial infarction related to the stented territory without angiographic confirmation; and possible refers to any unexplained death occurring from 30 days after implantation until the end of follow-up.

12 months
Cardiovascular mortality
時間枠:12 months

Any death due to an immediate cardiac cause (e.g., myocardial infarction, low-output heart failure, fatal arrhythmia), unwitnessed death, death of unknown cause, and all procedure-related deaths, including those related to concomitant treatment, will be classified as cardiac death.

12 months
Late in-segment luminal loss (including the in-stent portion and the 5-mm proximal and distal edges)
時間枠:6 months

Defined as the difference between the in-segment minimum luminal diameter (MLD) (including the in-stent portion and the 5-mm proximal and distal edges) after the procedure and the MLD at the 6-month follow-up, as determined by quantitative angiography.

6 months
Percent Area Stenosis (%AS)
時間枠:6 months

Defined as the ratio between the neointimal hyperplasia area and the stent area multiplied by 100 at the 6-month follow-up.

6 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Paulo Ricardo A Caramori, MD、Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月30日

一次修了 (推定)

2030年10月30日

研究の完了 (推定)

2030年10月30日

試験登録日

最初に提出

2026年3月16日

QC基準を満たした最初の提出物

2026年3月19日

最初の投稿 (実際)

2026年3月24日

学習記録の更新

投稿された最後の更新 (実際)

2026年10月2日

QC基準を満たした最後の更新が送信されました

2026年10月1日

最終確認日

2026年10月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する