このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

敗血症性ショックにおける輸液反応性の予測における動的SvO₂

2026年11月13日 更新者:Nevine Mostafa Soliman、Menoufia University

敗血症性ショックにおける輸液反応性予測における動的中心静脈酸素飽和度の診断精度:前向き観察研究

This prospective observational diagnostic accuracy study investigates the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock, compared to measurements obtained using echocardiography (VTI) and cardiometry. We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

調査の概要

詳細な説明

All patients will undergo standardized monitoring to ensure accurate and reproducible hemodynamic assessment throughout the study period.

Blood pressure will be monitored noninvasively using an automated oscillometric cuff applied to the upper arm. MAP will be maintained at ≥65 mmHg with vasopressor support as required, and no changes in vasopressor infusion will be permitted during the measurement period.

A central venous catheter will be inserted in the internal jugular or subclavian vein, with the position confirmed by chest radiography. Central venous blood samples will be collected at baseline and after the fluid challenge for the determination of a Central venous oxygen saturation (ScvO₂).

Echocardiographic Assessment Left ventricular outflow tract (LVOT) diameter will be measured in the parasternal long-axis view by transthoracic echocardiography (Sonoscape S8 Echocardiography), and Doppler assessment of velocity- time integral (VTI) will be obtained in the apical five-chamber view. Stroke volume (SV) will be calculated as LVOT area × VTI, and values will be averaged from three consecutive cardiac cycles over a single respiratory cycle. The echocardiography operator will be an expert intensivist in echo operation (more than 7 years of experience), and the operator will be blinded to ScvO2.

Cardiac Output Monitoring (Electrical Cardiometry) Cardiac output will also be assessed noninvasively using a validated electrical cardiometry device (ICON®, Osypka Medical, Germany).

Parameters including stroke volume, cardiac output, and cardiac index will be documented at baseline and after the fluid challenge. Device calibration will be verified before each study session.

Timing of Measurements

Hemodynamic variables and oxygenation parameters will be recorded at two prespecified time points:

  1. Baseline - immediately prior to fluid challenge or passive leg raising maneuver.
  2. Post-intervention - within 5 minutes following intervention. Intervention A standardized fluid challenge protocol will be employed. Indications for fluid administration will include: Hypotension, defined as systolic blood pressure (SBP) ≤ 90 mmHg, a reduction in SBP ≥ 40 mmHg in patients with pre-existing hypertension, or mean arterial pressure (MAP) ≤ 65 mmHg, or evidence of tissue hypoperfusion, such as delayed capillary refill time, skin mottling, altered mental status, urine output ≤ 0.5 mL/kg/h for > 2 hours, or hyperlactatemia (> 2 mmol/L).

Eligible patients will receive a rapid infusion of 500 mL isotonic crystalloid solution ( normal saline) administered over a 15-minute period.

Throughout the intervention, all concomitant therapies-including background maintenance fluids, vasopressor or inotrope dosage, and mechanical ventilation settings-will remain unchanged to avoid confounding effects on hemodynamic measurements.

Definition of Fluid Responsiveness Fluid responsiveness will be defined as an increase in stroke volume index (derived from echocardiography or cardiometry) of ≥10- 15% after the intervention. This definition is consistent with established hemodynamic criteria and will serve as the reference standard for comparison with dynamic changes in ScvO₂. Stroke Volume Index (SVI) is the volume of blood pumped by the heart's ventricle with each beat, normalized to the individual's body surface area (BSA).

Data Collection For each patient, the following variables were systematically recorded: Baseline characteristics

  • Demographic data (age, sex), and Comorbidities

  • Source of infection

  • Severity of illness scores:

    o Acute Physiology and Chronic Health Evaluation II (APACHE II) o Sequential Organ Failure Assessment (SOFA)

  • Life-support therapies as vasopressor use.

  • Clinical outcomes (ICU length of stay, mortality) Hemodynamic and laboratory parameters Measured at two time points: immediately before the fluid challenge and within five minutes after completion.

  • Heart rate (beats/min)

  • Blood pressure

  • Hemoglobin concentration (Hb, g/dL)

  • Cardiac output (CO) by echocsardiography and electrical cardiometry

  • Central venous blood gas analysis: Central venous oxygen saturation (ScvO₂)

研究の種類

観察的

入学 (推定)

115

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

確率サンプル

調査対象母集団

This single-center, prospective, observational study will be conducted in the Intensive Care Unit (ICU) at Menoufia University Hospitals. Adults spontaneously breathing patients with septic shock who undergo a fluid challenge as a part of their hemodynamic management in the first 24 hours will be eligible for enrollment. Ethical approval will be obtained from the ethics committee at the Menoufia Faculty of Medicine, and the study will follow ethical guidelines and secure approval from the Institutional Review Board (IRB). Written informed consent will be obtained from each participant or their legal surrogate before study inclusion.

説明

Inclusion Criteria:

  • Age > 18 years
  • Diagnosis of septic shock according to Sepsis-3 criteria:

Suspected or confirmed infection o Requirement for vasopressors to maintain MAP > 65 mmHg o Serum lactate > 2 mmol/L despite adequate fluid resuscitation

Exclusion Criteria:

  • Pregnancy
  • Significant valvular heart disease.
  • Atrial fibrillation.
  • Inadequate echocardiographic window.
  • Ongoing bleeding or contraindication to fluid bolus.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:COHORT
  • 時間の展望:PROSPECTIVE

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
ベースライン時および輸液負荷試験後の動的中心静脈酸素飽和度(ScvO2)の測定。
時間枠:30分後
30分後

二次結果の測定

結果測定
メジャーの説明
時間枠
Measuring Cardiac output by echocardiography or cardiometry at baseline and after fluid challenge.
時間枠:After 30 mins

We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

After 30 mins

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年11月1日

一次修了 (推定)

2027年1月1日

研究の完了 (推定)

2027年2月1日

試験登録日

最初に提出

2026年3月29日

QC基準を満たした最初の提出物

2026年4月2日

最初の投稿 (実際)

2026年4月7日

学習記録の更新

投稿された最後の更新 (実際)

2026年11月16日

QC基準を満たした最後の更新が送信されました

2026年11月13日

最終確認日

2026年1月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。