- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07516236
SvO2 Dinâmica na Previsão da Resposta aos Fluídos no Choque Séptico
Precisão Diagnóstica da Saturação Dinâmica de Oxigénio Venoso Central na Previsão da Resposta à Fluidoterapia no Choque Séptico: Um Estudo Observacional Prospectivo
This prospective observational diagnostic accuracy study investigates the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock, compared to measurements obtained using echocardiography (VTI) and cardiometry. We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.
Visão geral do estudo
Status
Condições
Descrição detalhada
All patients will undergo standardized monitoring to ensure accurate and reproducible hemodynamic assessment throughout the study period.
Blood pressure will be monitored noninvasively using an automated oscillometric cuff applied to the upper arm. MAP will be maintained at ≥65 mmHg with vasopressor support as required, and no changes in vasopressor infusion will be permitted during the measurement period.
A central venous catheter will be inserted in the internal jugular or subclavian vein, with the position confirmed by chest radiography. Central venous blood samples will be collected at baseline and after the fluid challenge for the determination of a Central venous oxygen saturation (ScvO₂).
Echocardiographic Assessment Left ventricular outflow tract (LVOT) diameter will be measured in the parasternal long-axis view by transthoracic echocardiography (Sonoscape S8 Echocardiography), and Doppler assessment of velocity- time integral (VTI) will be obtained in the apical five-chamber view. Stroke volume (SV) will be calculated as LVOT area × VTI, and values will be averaged from three consecutive cardiac cycles over a single respiratory cycle. The echocardiography operator will be an expert intensivist in echo operation (more than 7 years of experience), and the operator will be blinded to ScvO2.
Cardiac Output Monitoring (Electrical Cardiometry) Cardiac output will also be assessed noninvasively using a validated electrical cardiometry device (ICON®, Osypka Medical, Germany).
Parameters including stroke volume, cardiac output, and cardiac index will be documented at baseline and after the fluid challenge. Device calibration will be verified before each study session.
Timing of Measurements
Hemodynamic variables and oxygenation parameters will be recorded at two prespecified time points:
- Baseline - immediately prior to fluid challenge or passive leg raising maneuver.
- Post-intervention - within 5 minutes following intervention. Intervention A standardized fluid challenge protocol will be employed. Indications for fluid administration will include: Hypotension, defined as systolic blood pressure (SBP) ≤ 90 mmHg, a reduction in SBP ≥ 40 mmHg in patients with pre-existing hypertension, or mean arterial pressure (MAP) ≤ 65 mmHg, or evidence of tissue hypoperfusion, such as delayed capillary refill time, skin mottling, altered mental status, urine output ≤ 0.5 mL/kg/h for > 2 hours, or hyperlactatemia (> 2 mmol/L).
Eligible patients will receive a rapid infusion of 500 mL isotonic crystalloid solution ( normal saline) administered over a 15-minute period.
Throughout the intervention, all concomitant therapies-including background maintenance fluids, vasopressor or inotrope dosage, and mechanical ventilation settings-will remain unchanged to avoid confounding effects on hemodynamic measurements.
Definition of Fluid Responsiveness Fluid responsiveness will be defined as an increase in stroke volume index (derived from echocardiography or cardiometry) of ≥10- 15% after the intervention. This definition is consistent with established hemodynamic criteria and will serve as the reference standard for comparison with dynamic changes in ScvO₂. Stroke Volume Index (SVI) is the volume of blood pumped by the heart's ventricle with each beat, normalized to the individual's body surface area (BSA).
Data Collection For each patient, the following variables were systematically recorded: Baseline characteristics
-
Demographic data (age, sex), and Comorbidities
-
Source of infection
-
Severity of illness scores:
o Acute Physiology and Chronic Health Evaluation II (APACHE II) o Sequential Organ Failure Assessment (SOFA)
-
Life-support therapies as vasopressor use.
-
Clinical outcomes (ICU length of stay, mortality) Hemodynamic and laboratory parameters Measured at two time points: immediately before the fluid challenge and within five minutes after completion.
-
Heart rate (beats/min)
-
Blood pressure
-
Hemoglobin concentration (Hb, g/dL)
-
Cardiac output (CO) by echocsardiography and electrical cardiometry
-
Central venous blood gas analysis: Central venous oxygen saturation (ScvO₂)
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Locais de estudo
-
-
-
Menouf, Egito
- Recrutamento
- Menoufia University
-
Contato:
- Menoufia U MenoufiaU
- Número de telefone: 01128861471
- E-mail: mostafanevine@gmail.com
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
This single-center, prospective, observational study will be conducted in the Intensive Care Unit (ICU) at Menoufia University Hospitals. Adults spontaneously breathing patients with septic shock who undergo a fluid challenge as a part of their hemodynamic management in the first 24 hours will be eligible for enrollment. Ethical approval will be obtained from the ethics committee at the Menoufia Faculty of Medicine, and the study will follow ethical guidelines and secure approval from the Institutional Review Board (IRB). Written informed consent will be obtained from each participant or their legal surrogate before study inclusion.
Descrição
Inclusion Criteria:
- Age > 18 years
- Diagnosis of septic shock according to Sepsis-3 criteria:
Suspected or confirmed infection o Requirement for vasopressors to maintain MAP > 65 mmHg o Serum lactate > 2 mmol/L despite adequate fluid resuscitation
Exclusion Criteria:
- Pregnancy
- Significant valvular heart disease.
- Atrial fibrillation.
- Inadequate echocardiographic window.
- Ongoing bleeding or contraindication to fluid bolus.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: COHORT
- Perspectivas de Tempo: PROSPECTIVE
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Medição da saturação venosa central de oxigénio dinâmica (ScvO2) na linha de base e após o desafio de fluidos.
Prazo: Após 30 minutos
|
Após 30 minutos
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Measuring Cardiac output by echocardiography or cardiometry at baseline and after fluid challenge.
Prazo: After 30 mins
|
We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock. |
After 30 mins
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 1/2026ANET30
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .