Impact of Tracheal Tube Fixing Site on Its Mobility During Head Mobilization (Fix-IOT)
This study evaluate the secondary shifting of the tracheal tube when the head is moved under general anaesthesia. Two sites of fixation (the maxilla and the mandible) are tested in a prospective, double blind, randomized and crossover designed study.
The study test the hypothesis that taping the tracheal tube on the mandible better prevents a secondary tube move.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Tracheal intubation is the only technique to ensure airway protection, meaning preventing aspiration, and providing mechanical ventilation during general anesthesia (GA). This is an extremely frequent procedure. After intubation, the head of the patient is often moved as the patient is positioned for the surgical procedure (ENT, thoracic and abdominal surgeries, lateral or prone positioning…). This may even happen several times during the same procedure. It is well demonstrated that these head movements are responsible for secondary shifting of the tube (1-9). This can cause accidental extubation or selective bronchial intubation.
The anesthesiologist secures the tube with tape to prevent secondary displacement of the tracheal tube. The two most common sites to tape the tube on patient's face are the maxilla, because it is a fixed spot on the face, and the mandible, because its mobility coming from the temporomandibular joint may allow a better interlock with the larynx.
There is no study and no recommendation about the best site of tape. Both techniques are commonly used, depending on the anesthesiologist's preference.
Investigators designed a, controlled study in Brest university hospital to compare two groups by cross-over intervention (one group "maxilla fixing then mandible fixing" and one group "mandible fixing then maxilla fixing").
The population is composed of adult patients undergoing bronchoscopy or endobronchial ultrasound under GA and after tracheal intubation. The bronchoscope allows a permanent control of the tracheal tube's position, and the possibility of shifting it without compromising patient security, which is not possible in other daily surgical procedure.
Statisticien estimate that the total number of patients to include is 36. In order to avoid a sequence effect, the order of the fixing technique will be randomized. Every patient will be its own control as there is a cross over-design.
The main outcome is the maximal amplitude of the tracheal tube shifting when the head is bended on the chest and extended in the back, controlled by bronchoscopy with each fixing technique.
The anesthesiologist investigator will use the first fixing site according to the patient's randomization group. Then, he will display an opaque cover around the tracheal tube, so that the operator, who will measure the tube displacements, will stay blind. As the intervention is performed under GA, the patient will also be blind. The same procedure will be performed after the second fixing site is used, before the end of the intervention.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Brest, Frankrijk, 29200
- Brest University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Adult
- Bronchoscopy or endobronchial ultrasound
- General anaesthesia
- Tracheal intubation
Exclusion Criteria:
- Patient incapable of consenting or with a legal guardian or declining participation
- Forbidden or impaired cervical mobility (less than 80°)
- Mouth opening less than 35 mm
- Moustache or Beard
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ondersteunende zorg
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: maxilla fixing then mandible fixing
The tracheal tube is first fixed on the maxilla.
After the measures of the outcomes, its site of fixation is changed for the mandible for the outcome measurement in the second site of fixation.
|
Intubation device will be fixed on mandible
Intubation device will be fixed on maxilla
|
|
Actieve vergelijker: mandible fixing then maxilla fixing
The tracheal tube is first fixed on the mandible.
After the measures of the outcomes, its site of fixation is changed for the maxilla for the outcome measurement in the second site of fixation.
|
Intubation device will be fixed on mandible
Intubation device will be fixed on maxilla
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Maximal amplitude of the tracheal tube shifting
Tijdsspanne: 2 minutes
|
The main outcome is the maximal amplitude of the tracheal tube shifting when the head is bended on the chest and extended in the back, controlled by bronchoscopy with each fixing technique.
|
2 minutes
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Movement of the tracheal tube from the neutral position
Tijdsspanne: 2 minutes
|
For each fixation site (maxillary or mandibular), the tracheal tube displacement from the neutral position is measured when the head is bended on the chest and when it is extended in the back.
|
2 minutes
|
Medewerkers en onderzoekers
Sponsor
Publicaties en nuttige links
Algemene publicaties
- Conrardy PA, Goodman LR, Lainge F, Singer MM. Alteration of endotracheal tube position. Flexion and extension of the neck. Crit Care Med. 1976 Jan-Feb;4(1):8-12. doi: 10.1097/00003246-197601000-00002. No abstract available.
- Yap SJ, Morris RW, Pybus DA. Alterations in endotracheal tube position during general anaesthesia. Anaesth Intensive Care. 1994 Oct;22(5):586-8. doi: 10.1177/0310057X9402200515.
- Hartrey R, Kestin IG. Movement of oral and nasal tracheal tubes as a result of changes in head and neck position. Anaesthesia. 1995 Aug;50(8):682-7. doi: 10.1111/j.1365-2044.1995.tb06093.x.
- Sugiyama K, Yokoyama K. Displacement of the endotracheal tube caused by change of head position in pediatric anesthesia: evaluation by fiberoptic bronchoscopy. Anesth Analg. 1996 Feb;82(2):251-3. doi: 10.1097/00000539-199602000-00006.
- Rost JR, Frush DP, Auten RL. Effect of neck position on endotracheal tube location in low birth weight infants. Pediatr Pulmonol. 1999 Mar;27(3):199-202. doi: 10.1002/(sici)1099-0496(199903)27:33.0.co;2-o.
- Olufolabi AJ, Charlton GA, Spargo PM. Effect of head posture on tracheal tube position in children. Anaesthesia. 2004 Nov;59(11):1069-72. doi: 10.1111/j.1365-2044.2004.03963.x.
- Weiss M, Knirsch W, Kretschmar O, Dullenkopf A, Tomaske M, Balmer C, Stutz K, Gerber AC, Berger F. Tracheal tube-tip displacement in children during head-neck movement--a radiological assessment. Br J Anaesth. 2006 Apr;96(4):486-91. doi: 10.1093/bja/ael014. Epub 2006 Feb 7.
- Jordi Ritz EM, Von Ungern-Sternberg BS, Keller K, Frei FJ, Erb TO. The impact of head position on the cuff and tube tip position of preformed oral tracheal tubes in young children. Anaesthesia. 2008 Jun;63(6):604-9. doi: 10.1111/j.1365-2044.2008.05440.x.
- Kim JT, Kim HJ, Ahn W, Kim HS, Bahk JH, Lee SC, Kim CS, Kim SD. Head rotation, flexion, and extension alter endotracheal tube position in adults and children. Can J Anaesth. 2009 Oct;56(10):751-6. doi: 10.1007/s12630-009-9158-y. Epub 2009 Jul 29.
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- 29BRC17.0025
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op mandible fixation
-
Nanchong Central HospitalAanmelden op uitnodiging
-
London Health Sciences Centre Research Institute...Orthopaedic Trauma AssociationWervingDistale dijbeenfracturenCanada
-
Orthofix s.r.l.Actief, niet wervendBreuken van de lange botten | Verticaal stabiele bekkenfracturen | Verticaal instabiele bekkenfracturenItalië
-
SC MedicaWervingDegeneratieve lumbale spinale stenoseFrankrijk
-
Eva Koetsier MD PhDProf. Dr. Med. Alessandro Cianfoni, MD PhD, Neurocenter of Southern Switzerland...Nog niet aan het wervenOnstabiele osteoporotische wervelcompressiefracturenZwitserland
-
Instituto Traumatologico Dr. Teodoro Gebauer WeisserOnbekend
-
Abyrx, Inc.Nog niet aan het wervenPostoperatieve complicaties | Cranioplastiek | Schedelbot | Schedelfixatie | Lijmbotcement
-
Indonesia UniversityBeëindigdMaxillofaciale verwondingen | Fractuurfixatie, intern | Maxillofaciale prothese implantatieIndonesië
-
Cairo UniversityVoltooidInguinale herniaEgypte
-
Essity Hygiene and Health ABNog niet aan het wervenHuid (FLACC-scores van proefpersonen) na verwijdering van de tapeZweden