Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Heart Rate Evaluation and Resuscitation Trial in Preterm Neonates (HEART)

19 grudnia 2018 zaktualizowane przez: Vishal Kapadia, University of Texas Southwestern Medical Center
The purpose of this study is to determine whether using electrocardiograms (ECGs) during resuscitation of preterm infants (less than 31 weeks gestation) will decrease the amount of time it takes from birth for heart rate (HR) to be above 100 beats per minute and oxygen saturations to be in the goal range, in other words to stabilize the infant. A few studies have been conducted which showed that ECGs are faster at detecting HR than pulse oximetry (PO). Sample sizes, however, have been small and only few extremely low birthweight infants have been included. It is unclear if use of ECG in these tiny preterm infants in addition to traditional techniques to determine HR will be beneficial and impact resuscitation and outcomes. The investigators propose a study where infants will be randomized to either using ECG in addition to PO ± auscultation versus PO ± auscultation only to assess HR during neonatal resuscitation. The investigators hypothesize that the group of infants randomized to ECG will be able to stabilize faster, i.e. achieve HR > 100 beats per minute and oxygen saturation in goal range faster.

Przegląd badań

Status

Zakończony

Warunki

Interwencja / Leczenie

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

51

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

Nie starszy niż 1 godzina (Dziecko)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Preterm infants less than <31 weeks gestation born at Parkland hospital vaginally or by C/S
  • Infant with congenital heart disease, congenital anomalies, or chromosomal abnormalities will be included unless comfort care has been agreed upon beforehand
  • Resuscitation team present to attend delivery before birth

Exclusion Criteria:

  • Any infant with prenatally agreed upon comfort care since resuscitation will not be provided
  • Any precipitous delivery since resuscitation team will not be in attendance prior to delivery

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Inny
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Control group
Pulse oximeter and auscultation to determine heart rate during neonatal resuscitation. Pulse oximeter will be used to determine oxygen saturation.
Control
Eksperymentalny: Electrocardiogram group
Electrocardiogram to determine heart rate during neonatal resuscitation. Pulse oximeter will still be used per Neonatal Resuscitation Program guidelines for oxygen saturation.
Experimental

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Time to Infant Stabilization
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Amount of time it takes from birth for heart rate to be above 100 beats per minute and oxygen saturation to be in the goal range (per Neonatal Resuscitation Program guidelines)
During delivery room resuscitation, up to 1 hour

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Time to heart rate >100 beats per minute
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Time in delivery room
During delivery room resuscitation, up to 1 hour
Time to goal oxygen saturation
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Time in delivery room
During delivery room resuscitation, up to 1 hour
Time of positive pressure ventilation
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Total time positive pressure received in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of positive pressure ventilation
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Positive pressure ventilation applied in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of CPR
Ramy czasowe: During delivery room resuscitation, up to 1 hour
CRP applied in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of intubation
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Intubation in delivery room
During delivery room resuscitation, up to 1 hour
Maximum FiO2 applied
Ramy czasowe: During delivery room resuscitation, up to 1 hour
FiO2 applied in delivery room
During delivery room resuscitation, up to 1 hour
Maximum peak inspiratory pressure
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Maximum peak inspiratory pressure in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of hypothermia
Ramy czasowe: Until hospital discharge, up to 6 months
Hypothermia on admission to NICU
Until hospital discharge, up to 6 months
Incidence of need for surfactant
Ramy czasowe: Until hospital discharge, up to 6 months
Surfactant given while in NICU
Until hospital discharge, up to 6 months
Incidence of bronchopulmonary dysplasia
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of respiratory distress syndrome
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of pneumothorax
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of intraventricular hemorrhage
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of necrotizing enterocolitis
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of sepsis
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of symptomatic PDA
Ramy czasowe: Until hospital discharge, up to 6 months
Incidence in NICU
Until hospital discharge, up to 6 months
Incidence of appropriate vs inappropriate use of positive pressure ventilation
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Use in delivery room
During delivery room resuscitation, up to 1 hour
Incidence of equipment failure of pulse oximeter and electrocardiogram
Ramy czasowe: During delivery room resuscitation, up to 1 hour
Failure in delivery room
During delivery room resuscitation, up to 1 hour

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

13 czerwca 2017

Zakończenie podstawowe (Rzeczywisty)

23 marca 2018

Ukończenie studiów (Rzeczywisty)

23 marca 2018

Daty rejestracji na studia

Pierwszy przesłany

22 kwietnia 2017

Pierwszy przesłany, który spełnia kryteria kontroli jakości

25 kwietnia 2017

Pierwszy wysłany (Rzeczywisty)

28 kwietnia 2017

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

21 grudnia 2018

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

19 grudnia 2018

Ostatnia weryfikacja

1 grudnia 2018

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 092016-048

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

Nie

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Pulse oximeter and auscultation group

Wyszukaj podobne próby