Safety, Tolerability, and Accuracy of a Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults
Safety, Tolerability, and Accuracy of a Novel Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor in Healthy Adults: A Single-Center, Single-Arm Exploratory Clinical Trial
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Peiyao Jin
- Numer telefonu: +8613564534911
- E-mail: peiyaojin@hotmail.com
Lokalizacje studiów
-
-
Shanghai Municipality
-
Shanghai, Shanghai Municipality, Chiny, 200080
- Shanghai General Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Voluntarily agrees to participate in the study and provides written informed consent.
- Has previously worn contact lenses.
- Has no ocular disease other than refractive error.
- Central corneal thickness between 540 and 560 μm, inclusive.
- Corneal curvature between 42 and 44 D, inclusive.
Exclusion Criteria:
- Unable to tolerate the hydrogel-based wearable dynamic intraocular pressure sensor.
- Pregnant or breastfeeding.
- History of allergy to relevant medical materials or known hypersensitivity to materials used in the investigational device.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Hydrogel-Based Wearable Dynamic Intraocular Pressure Sensor
Participants will undergo a single-arm evaluation of a hydrogel-based wearable dynamic intraocular pressure sensor (CLS). After 2 hours of fasting from food and water, baseline ocular safety examinations will be performed. Intraocular pressure will first be measured using non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT). Participants will then wear the CLS and undergo a 10-minute adaptation period before the first sensor signal is recorded. Participants will drink 1 L of water within 5 minutes. At 10-15 minutes after completion of water intake, a second sensor signal will be recorded, followed by CLS removal and repeat GAT and NCT measurements. After an interval of at least 45 minutes, NCT and GAT will be repeated, the CLS will be worn again for a 10-minute adaptation period, and a third sensor signal will be recorded. After completion of the measurement procedure, the CLS will be removed and ocular safety examinations will be repeated to evaluate changes associate |
The investigational device is a wearable hydrogel-based contact lens sensor designed to record electrical signals associated with changes in intraocular pressure.
The CLS is worn on the study eye and allowed to stabilize for 10 minutes before signal acquisition.
Sensor signals are obtained at three predefined measurement points and compared with Goldmann applanation tonometry measurements to assess measurement accuracy.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Absolute Error of CLS-Predicted Intraocular Pressure Compared With Goldmann Applanation Tonometry
Ramy czasowe: Day 1, at the third validation measurement
|
The first two paired measurements of the contact lens sensor (CLS) signal and Goldmann applanation tonometry (GAT) intraocular pressure will be used to establish an individualized linear calibration equation for each participant.
The third CLS signal will be converted to a predicted intraocular pressure using the individualized calibration equation.
Absolute error is defined as the absolute difference between the CLS-predicted intraocular pressure and the corresponding GAT measurement, expressed in mmHg.
|
Day 1, at the third validation measurement
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Agreement Between CLS-Predicted Intraocular Pressure and Non-Contact Tonometry
Ramy czasowe: Day 1, at the third validation measurement
|
At the third validation assessment, intraocular pressure predicted from the contact lens sensor (CLS) using the individualized calibration equation will be compared with the corresponding non-contact tonometry (NCT) measurement.
|
Day 1, at the third validation measurement
|
|
Increased incidence of corneal fluorescent staining grade
Ramy czasowe: Baseline and at the post-study ocular examination on Day 1
|
Corneal fluorescence staining grading (National Eye Institute (NEI) standards) The cornea is divided into five regions (central, top, and above).Square, inferior, nasal side, temporal side), each area scores 0-3 points (0 = unstained, 1 = sparse dots, 2 = dense dots, 3 = fused or patchy)
|
Baseline and at the post-study ocular examination on Day 1
|
|
Conjunctival congestion score
Ramy czasowe: Baseline and at the post-study ocular examination on Day 1
|
The Ora Calibra® scale was used to measure conjunctival redness in each eye.
Each eye will be rated on a scale from 0 to 4, with 0 being best and 4 being the worst.
|
Baseline and at the post-study ocular examination on Day 1
|
|
Change From Baseline in Tear Break-Up Time After CLS Wear
Ramy czasowe: Baseline and at the post-study ocular examination on Day 1
|
Tear break-up time (TBUT) will be measured before and after CLS wear.
After blinking several times, the participant will keep the eye open while looking straight ahead, and the time until the first dry spot appears in the tear film will be recorded in seconds.
|
Baseline and at the post-study ocular examination on Day 1
|
|
Change From Baseline in Best-Corrected Visual Acuity After CLS Wear
Ramy czasowe: Baseline and at the post-study ocular examination on Day 1
|
Best-corrected visual acuity (BCVA) will be assessed before and after CLS wear.
Change from baseline will be calculated by comparing the post-study BCVA with the baseline BCVA.
|
Baseline and at the post-study ocular examination on Day 1
|
|
CLDEQ-8-Based Immediate Ocular Tolerability Questionnaire
Ramy czasowe: Immediately after completion of CLS wear on Day 1
|
Immediate ocular tolerability during wear of the investigational contact lens sensor (CLS) will be assessed using a study-specific questionnaire adapted from the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8). The questionnaire contains eight items assessing: frequency and intensity of ocular discomfort, frequency and intensity of ocular dryness, frequency and intensity of fluctuating or blurred vision, frequency of wanting to close the eye because of discomfort, and the desire to remove the CLS because of discomfort. Frequency items are scored from 0 to 4, intensity items from 0 to 5, and the item assessing the desire to remove the CLS from 1 to 6. Higher scores indicate worse ocular tolerability. |
Immediately after completion of CLS wear on Day 1
|
Współpracownicy i badacze
Sponsor
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 20260424074539870
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .