Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an "endogenous fluid challenge".

Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.

Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication.

Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

40

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Italy
      • Rome, Italy, Itália, 00168
        • IRCCS Fondazione Policlinico Universitario Agostino Gemelli

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Fêmea

Descrição

Inclusion Criteria:

Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.

Exclusion Criteria:

  1. age < 18 yo;
  2. preeclampsia;
  3. eclampsia;
  4. atrial fibrillation and sinus tachycardia;
  5. cardiovascular diseases;
  6. neuromuscular disease;
  7. emergent or urgent cesarean delivery;
  8. coagulopathies;
  9. contraindications to spinal anesthesia.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Ciência básica
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Hemodynamic Assessment

All participants underwent the same protocol-specified procedures, including a 250-mL crystalloid fluid challenge and continuous non-invasive hemodynamic monitoring using ClearSight. Standard prophylactic norepinephrine was administered during spinal anesthesia for elective cesarean delivery. Participants were categorized according to left ventricular diastolic function (normal or impaired) for subsequent physiological analyses. No allocation to different treatments was performed.

Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes

All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line.

The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Indexed Cardiac Output
Prazo: Baseline/after spinal anesthesia/after delivery

We aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring.

Baseline/after spinal anesthesia/after delivery

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Indexed Stroke Volume
Prazo: Baseline/after spinal anesthesia/after delivery

We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring.

Baseline/after spinal anesthesia/after delivery
Systolic Blood Pressure
Prazo: Baseline/after spinal anesthesia/after delivery

We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring.

Baseline/after spinal anesthesia/after delivery
Heart Rate
Prazo: Baseline/after spinal anesthesia/after delivery

We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring.

Baseline/after spinal anesthesia/after delivery
Apgar Scores
Prazo: Decreases of Indexed Cardiac Output after spinal anesthesia

We ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring.

Decreases of Indexed Cardiac Output after spinal anesthesia

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

10 de outubro de 2019

Conclusão Primária (Real)

15 de dezembro de 2020

Conclusão do estudo (Real)

15 de dezembro de 2020

Datas de inscrição no estudo

Enviado pela primeira vez

11 de setembro de 2020

Enviado pela primeira vez que atendeu aos critérios de CQ

17 de setembro de 2020

Primeira postagem (Real)

23 de setembro de 2020

Atualizações de registro de estudo

Última Atualização Postada (Real)

3 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

30 de outubro de 2026

Última verificação

1 de outubro de 2026

Mais Informações

Termos relacionados a este estudo

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever