Predictors of Sleep Quality in Patients Undergoing Open-Heart Surgery
Predictors of Sleep Quality in Patients Undergoing Open-Heart Surgery: A Hierarchical Regression Analysis
Visão geral do estudo
Status
Status
Condições
Condições
Descrição detalhada
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
Zafer Mahallesi
-
Aydin, Zafer Mahallesi, Turquia (Türkiye), 09010
- Aydın Adnan Menderes University
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- ability to understand and speak Turkish,
- willingness to participate in the study,
- having spent at least 24 hours in the intensive care unit, and
- having the cognitive ability to understand and answer questions.
Exclusion Criteria:
- having taken narcotic or sedative drugs within the last 48 hours,
- having a history of chronic diseases that can cause sleep problems such as Chronic Obstructive Pulmonary Disease or sleep apnea,
- having a psychiatric illness diagnosed by a physician,
- having a visual or hearing impairment.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Pain
Prazo: At least 24 hours after admission to the intensive care unit
|
Assessed wit Visual Analog Scale.
his scale is a unidimensional, self-report instrument measuring 10 cm in length.
The lower end corresponds to a score of 0, labeled 'no pain,' while the upper end corresponds to a score of 10, labeled 'unbearable pain.' Higher scores on the scale indicate greater severity of pain as reported by the patient.
|
At least 24 hours after admission to the intensive care unit
|
|
Sleep quality
Prazo: At least 24 hours after admission to the intensive care unit
|
Assessed with Richard- Campbell Sleep Questionnaire. he scale consists of 6 items assessing sleep quality, nocturnal sleep depth, frequency of awakening, ambient noise level, time spent awake, and sleep onset latency.
Each item is rated on a visual analog scale ranging from 0 to 100.
The total score obtained from the scale is divided by the number of items to calculate the scale score.
A scale score between 0 and 25 is interpreted as very poor sleep, while a score between 76 and 100 is interpreted as very good sleep.
|
At least 24 hours after admission to the intensive care unit
|
|
Fatigue
Prazo: At least 24 hours after admission to the intensive care unit
|
Assessed wit Visual Analog Scale.
his scale is a unidimensional, self-report instrument measuring 10 cm in length.
The lower end corresponds to a score of 0, labeled 'no fatigue,' while the upper end corresponds to a score of 10, labeled 'unbearable fatigue.'
Higher scores on the scale indicate greater severity of fatigue as reported by the patient.
|
At least 24 hours after admission to the intensive care unit
|
|
Environmental Stressors
Prazo: At least 24 hours after admission to the intensive care unit
|
Assessed with Intensive Care Unit Environmental Stressors Scale.
The scale is of a 4-point Likert type and consists of 42 items.
The minimum possible score is 42 and the maximum is 168.
Higher scores are interpreted as indicating a greater degree of being affected by environmental stressors.
|
At least 24 hours after admission to the intensive care unit
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- Predictors of Sleep Quality
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Prazo de Compartilhamento de IPD
Tipo de informação de suporte de compartilhamento de IPD
- PROTOCOLO DE ESTUDO
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .