- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT06636994
Анатомические и функциональные прогнозы способностей к слепому зрению у пациентов с гомонимной боковой гемианопсией (PRE-SIGHT)
Homonymous lateral hemianopia (HLH) is characterized by loss of vision in half the visual field, and is the most common neurovisual disorder following stroke.
Numerous behavioral and neuroanatomical studies have focused on the phenomenon of blindsight, corresponding to patients' unconscious residual visual capacities in the blind hemifield. Cohort studies of patients have highlighted different types of blindsight, and a low occurrence of the phenomenon initially described: (1) type 1 blindsight (≈12%), unconscious visual abilities; (2) type 2 blindsight, visual abilities associated with sensations in the blind field (≈18%); (3) blindsense, sensations in the blind field without visual abilities (≈30%); and (4) no blindsight (≈40%). The heterogeneity of these blindsight abilities in the HLH population is closely related to patients' neuroanatomical and functional profiles.
In particular, resting-state functional imaging (r-fMRI) and default mode network analysis have highlighted a significant correlation between the degree of inter-hemispheric connection (between the healthy and injured hemispheres) and the rate of spontaneous visual field recovery. To our knowledge, this degree of functional connectivity has not yet been studied in relation to blindsight abilities. However, this functional MRI measurement tool represents a potential predictive factor for patients' residual performance in their blindsight field, in order to assess the level of visuo-cognitive impairment and, ultimately, to adapt care.
Обзор исследования
Статус
Тип исследования
Регистрация (Оцененный)
Контакты и местонахождение
Контакты исследования
- Имя: Amelie Yavchitz, Dr
- Номер телефона: 0148036454
- Электронная почта: ayavchitz@for.paris
Учебное резервное копирование контактов
- Имя: Sadia MEDAOURI
- Номер телефона: 0148036277
- Электронная почта: smedaouri@for.paris
Места учебы
-
-
-
Paris, Франция, 75019
- Hopital Fondation Adolphe de Rothschild
-
Контакт:
- clementine GARRIC
- Электронная почта: clgarric@for.paris
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Patients over 18 years of age with homonymous lateral hemianopia undergoing cerebral MRI for follow-up and rehabilitation following stroke
Описание
Inclusion Criteria:
- Subjects aged 18 and over
- with homonymous visual field amputation sequelae of a retrochiasmatic lesion of vascular origin (stroke), including the occipital region (primary visual cortex, optic radiations, associated occipital areas)
- Requires follow-up brain MRI as part of treatment
- Able to perform experimental tasks on computer
- Express consent to participate in the study
- Member or beneficiary of a social security scheme
Exclusion Criteria:
- Severe neuropsychological disorders (language, memory, attention, vigilance, reasoning)
- Severe ophthalmological disorders or visual acuity below 3/10 prior to stroke
- Progressive ophthalmological disorders (cataract or glaucoma) likely to bias measurements
- Major psychiatric or behavioral disorders making care impossible
- Patient benefiting from a legal protection measure
- Pregnant or breast-feeding women (declarative information)
Учебный план
Как устроено исследование?
Детали дизайна
- Наблюдательные модели: CASE_ONLY
- Временные перспективы: CROSS_SECTIONAL
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Description of resting-state functional MRI measurement of the degree of Resting State Functional Connectivity (RSFC) between left and right hemisphere regions.
Временное ограничение: DAY 0
|
Comparison of the degree of inter-hemispheric Resting State Functional Connectivity between the four patient groups: absence of blindsight, type I blindsight, type II blindsight and blindsense. |
DAY 0
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Correlation between inter-hemispheric functional connectivity and blindsight performance
Временное ограничение: DAY 0
|
Resting-state functional MRI measurement of the degree of RSFC between left and right hemisphere regions of interest. Blindsight performance assessed by measuring the sensitivity of discrimination of spatial orientation (horizontal/vertical) of lines presented in the patient's blind field (blindsight). |
DAY 0
|
|
Density and intensity of visual and attentional default networks in each type of blindsight
Временное ограничение: DAY 0
|
Calculation (Graph Theory) of neural network matrices, weighted and created on the basis of correlations of activations in different brain regions during resting-state functional MRI measurement . |
DAY 0
|
|
Blindsight performance according to the laterality of the lesion (left or right hemisphere)
Временное ограничение: DAY 0
|
Blindsight performance assessed by measuring the sensitivity of discrimination of spatial orientation (horizontal/vertical) of lines presented in the patient's blind field (blindsight) |
DAY 0
|
|
Correlation between the level of inter-hemispheric functional connectivity and blindsight performance
Временное ограничение: DAY 0
|
Resting-state functional MRI measurement of the degree of Resting State Functional Connectivity (RSFC) between left and right hemisphere regions of interest, blindsight performance assessed by measuring the sensitivity of spatial orientation discrimination (horizontal/vertical) of lines presented in the blindsight field. |
DAY 0
|
|
Correlation between visual default network density and intensity and blindsight performance
Временное ограничение: DAY 0
|
Computation (Graph Theory) of neural network matrices, weighted and created on the basis of correlations of activations of different brain regions during Resting-state functional MRI measurement. Blindsight performance assessed by measuring the sensitivity of discrimination of spatial orientation (horizontal/vertical) of lines presented in the patient's blind field (blindsight). |
DAY 0
|
|
Correlation between lesion volume and blindsight performance
Временное ограничение: DAY 0
|
Blindsight performance assessed by measuring the sensitivity of spatial orientation discrimination (horizontal/vertical) of lines presented in the patient's blind field (blindsight). |
DAY 0
|
Соавторы и исследователи
Следователи
- Главный следователь: Clémentine GARRIC, Integrative Neuroscience and Cognition Center
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
- Неврологические проявления
- Цереброваскулярные расстройства
- Заболевания головного мозга
- Заболевания центральной нервной системы
- Заболевания нервной системы
- Сосудистые заболевания
- Сердечно-сосудистые заболевания
- Глазные болезни
- Нарушения зрения
- Расстройства чувствительности
- Слепота
- Патологические состояния, признаки и симптомы
- Признаки и симптомы
- Инсульт
- Гемианопсия
- Слепота, корковая
Другие идентификационные номера исследования
- CGC_2024_3
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .