Dexcom G6® 和 FreeStyle Libre® 传感器在标准化低氧血症条件下的准确性
The major aim is to evaluate accuracy of 2 Continuous Glucose Monitoring Systems (CGMS) : Dexcom G6® and FreeStyle Libre® in standardized hypoxemia conditions (artificial normobaric hypoxia).
Our purpose is to demonstrate the good performance and calibration of these CGM sensors in hypoxemia conditions.
研究概览
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Poitiers、法国、86000
- CHU
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria: all population
- No history of respiratory diseases (childhood asthma, respiratory allergies, exercise-induced asthma or dyspnea)
- Willing to participate and able to sign an informed consent form (ICF)
- Being affiliated with the French Social Security
Inclusion Criteria:Patients with diabetes
- type 1 diabetes mellitus or type 2 diabetes mellitus (ADA definition)
- Age : 18 to 75 years
- stable diabetes treatment for more than 3 months
- no diabetic retinopathy
- no diabetic neuropathy
- no cardiovascular diseases
- no contra-indication for coronary computed tomography angiography or myocardial perfusion scintigraphy.
Inclusion Criteria: Healthy volunteers
- Age : 18 ; 40 years
- No diabetes
- No persistant drug use > 3 months except contraception
- Body mass index : [18,5 - 29,9] kg/m2
Non-inclusion criteria : all population
- Active smokers
- Pregnant or breastfeeding women, women of childbearing age without effective contraception
- Known allergies to the patch.
- Skin lesions at the sensor site that may interfere with sensor placement or accuracy
- Major cardiovascular complications within the past 3 months
- Decompensated congestive heart failure
- Chronic respiratory failure
- Chronic renal failure
- Resting ambient air O2 saturation ≤95%.
- Treatment with systemic corticosteroids
- Severe hypertension (≥180 mmHg systolic pressure or ≥ 100 mmHg diastolic pressure)
- Any concomitant disease or condition that the investigator believes may compromise patient safety or affect the conduct of the study
- Anemia (Hb<12g/dl)
- History of severe mountain sickness
- Concurrent participation in another clinical research study,
- Persons benefiting from enhanced protection
Non-inclusion criteria: Patients with diabetes
- Absolute contraindications to physical activity (HAS definitin) :
- Pulmonary arterial hypertension (> 60 mm Hg)
- Presence of intra-cardiac thrombus
- Acute pericardial effusion
- Severe obstructive cardiomyopathy
- Symptomatic aortic stenosis
- Recent thrombophlebitis with or without pulmonary embolism
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:group 1 : FreeStyle Libre 2 on right arm and Dexcom G6 on left arm
In this group, participants will be continuously monitored for their interstitial glucose level with 2 CGM devices : FreeStyle Libre 2 will be applied on right arm and Dexcom G6 will be applied on left arm. |
Participants will be exposed to a 3-hour acute hypoxia |
|
有源比较器:group 2 : 2 FreeStyle Libre 2 on left arm and Dexcom G6 on right arm
In this group, participants will be continuously monitored for their interstitial glucose level with 2 CGM devices : Dexcom G6 will be applied on right arm and FreeStyle Libre 2 will be applied on left arm. |
Participants will be exposed to a 3-hour acute hypoxia |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Mean Absolute Relative Difference (MARD)
大体时间:Day 1
|
The primary endpoint for measuring the accuracy of CGMs (individually) compared to venous blood glucose was the mean absolute relative difference, expressed as a percentage. As the percentages obtained did not follow a normal distribution, they are expressed in the table as median and IQR. |
Day 1
|
合作者和调查者
出版物和有用的链接
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.