- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT05144802
Nøyaktighet av Dexcom G6® og FreeStyle Libre® sensorer i standardiserte hypoksemiforhold
The major aim is to evaluate accuracy of 2 Continuous Glucose Monitoring Systems (CGMS) : Dexcom G6® and FreeStyle Libre® in standardized hypoxemia conditions (artificial normobaric hypoxia).
Our purpose is to demonstrate the good performance and calibration of these CGM sensors in hypoxemia conditions.
Studieoversikt
Status
Intervensjon / Behandling
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Poitiers, Frankrike, 86000
- CHU
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria: all population
- No history of respiratory diseases (childhood asthma, respiratory allergies, exercise-induced asthma or dyspnea)
- Willing to participate and able to sign an informed consent form (ICF)
- Being affiliated with the French Social Security
Inclusion Criteria:Patients with diabetes
- type 1 diabetes mellitus or type 2 diabetes mellitus (ADA definition)
- Age : 18 to 75 years
- stable diabetes treatment for more than 3 months
- no diabetic retinopathy
- no diabetic neuropathy
- no cardiovascular diseases
- no contra-indication for coronary computed tomography angiography or myocardial perfusion scintigraphy.
Inclusion Criteria: Healthy volunteers
- Age : 18 ; 40 years
- No diabetes
- No persistant drug use > 3 months except contraception
- Body mass index : [18,5 - 29,9] kg/m2
Non-inclusion criteria : all population
- Active smokers
- Pregnant or breastfeeding women, women of childbearing age without effective contraception
- Known allergies to the patch.
- Skin lesions at the sensor site that may interfere with sensor placement or accuracy
- Major cardiovascular complications within the past 3 months
- Decompensated congestive heart failure
- Chronic respiratory failure
- Chronic renal failure
- Resting ambient air O2 saturation ≤95%.
- Treatment with systemic corticosteroids
- Severe hypertension (≥180 mmHg systolic pressure or ≥ 100 mmHg diastolic pressure)
- Any concomitant disease or condition that the investigator believes may compromise patient safety or affect the conduct of the study
- Anemia (Hb<12g/dl)
- History of severe mountain sickness
- Concurrent participation in another clinical research study,
- Persons benefiting from enhanced protection
Non-inclusion criteria: Patients with diabetes
- Absolute contraindications to physical activity (HAS definitin) :
- Pulmonary arterial hypertension (> 60 mm Hg)
- Presence of intra-cardiac thrombus
- Acute pericardial effusion
- Severe obstructive cardiomyopathy
- Symptomatic aortic stenosis
- Recent thrombophlebitis with or without pulmonary embolism
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Grunnvitenskap
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Ingen (Open Label)
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: group 1 : FreeStyle Libre 2 on right arm and Dexcom G6 on left arm
In this group, participants will be continuously monitored for their interstitial glucose level with 2 CGM devices : FreeStyle Libre 2 will be applied on right arm and Dexcom G6 will be applied on left arm. |
Participants will be exposed to a 3-hour acute hypoxia |
|
Aktiv komparator: group 2 : 2 FreeStyle Libre 2 on left arm and Dexcom G6 on right arm
In this group, participants will be continuously monitored for their interstitial glucose level with 2 CGM devices : Dexcom G6 will be applied on right arm and FreeStyle Libre 2 will be applied on left arm. |
Participants will be exposed to a 3-hour acute hypoxia |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Mean Absolute Relative Difference (MARD)
Tidsramme: Day 1
|
The primary endpoint for measuring the accuracy of CGMs (individually) compared to venous blood glucose was the mean absolute relative difference, expressed as a percentage. As the percentages obtained did not follow a normal distribution, they are expressed in the table as median and IQR. |
Day 1
|
Samarbeidspartnere og etterforskere
Sponsor
Publikasjoner og nyttige lenker
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- FOX
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .