人类第一综合内窥镜超声(EUS)导航系统临床研究 (EZ-EUS1)
The complexity of the medical expertise required for endoscopic manipulation and image interpretation complicates the implementation of echo-endoscopy (or EUS for "Endoscopic Ultrasound").
The "EZ-EUS" system is designed to help the operator understand the orientation and the position of the probe tip in the patient. This system offers navigation similar to that of the Global Positioning System (GPS), but for EUS procedures. To achieve this, it uses a 3D model based on scanner imaging data recorded before the procedure.
In this study, the intended purpose of the "EZ-EUS" system is to help echo-endoscopy operators to easily identify and assess the pancreatic gland, and to facilitate the detection of any lesions.
The hypothesis is that, thanks to this tool, procedure times will be shortened, and the pancreas and its lesions will be fully imaged to facilitate their localization and characterization.
研究概览
详细说明
Since its inception in the 1980s, the field of endoscopic ultrasound (EUS) has experienced significant expansion and evolution and is now a pivotal component of pancreatobiliary assessment. Proficiency in EUS necessitates a synthesis of cognitive and technical competencies encompassing endoscopic manipulation, image interpretation, and an extensive comprehension of intraabdominal anatomical structures. Acquisition of these competencies is a progressive and highly operator-dependent process, and thereby necessitates an extended learning curve for practitioners.
The American Society for Gastrointestinal Endoscopy (ASGE) has recommended the performance of a minimum of 190 supervised EUS for practicing autonomous EUS. However, the compliance of these parameters does not guarantee competence achievement, and there is a wide variability between endoscopists leading to disparities in the techniques' quality and irregular outcomes.
The "EZ-EUS" system is designed to help the operator understand the orientation and the position of the probe tip in the patient. This system offers navigation similar to that of the Global Positioning System (GPS), but for EUS procedures. To achieve this, it uses a 3D model based on scanner imaging data recorded before the procedure.
In this study, the intended purpose of the "EZ-EUS" system is to assist echo-endoscopy operators in accurately locating the pancreatic gland, conducting a comprehensive evaluation of the region of interest, and facilitating the detection and identification of lesions within it. We hypothesize that this tool will streamline procedure times and enable comprehensive imaging of the pancreas and its lesions, thereby reducing the need for expert guidance for trainees and shortening the EUS learning curve. This study is exploratory, prospective, monocentric and will compare two randomized groups (with and without the EZ-EUS navigation system).
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Strasbourg、法国、67000
- Hôpitaux Universitaires de Strasbourg
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Man or woman over the age of 18 years old.
- Patient having a EUS procedure for pancreas study planned within the frame of his or her clinical care.
- Patient whom pre-operative imaging indicates one lesion, a suspicion of lesion, chronic pancreatitis or fatty pancreas.
- Patient with a good definition on the CT scan done within the year to the EUS.
- Patient able to receive and understand information related to the study and give his or her written consent.
- Patient affiliated to the French social security system.
Exclusion Criteria:
- Patient with altered anatomy of the upper digestive tract due to previous surgery.
- Patient with known abnormal anatomy of the upper digestive tract.
- Patient wearing a pacemaker.
- Patients with comorbidities that may increase the risk of perforation.
- Patient presenting, according to the investigator's judgment, a disease which may prevent participation in the procedures provided for by the study.
- Patient with an ASA >3. Patient with ASA=3 must be validated by the Principal
- Investigator (PI).
- Patient unable to tolerate general anesthesia.
- Patient with a body mass index (BMI) < 18,5 and > 40.
- Patient with weight variations >10% between the date on which the CT scan was performed and the date of the procedure.
- Pregnant or lactating patient.
- Patient in exclusion period (determined by a previous or a current study).
- Patient under guardianship or trusteeship.
- Patient under the protection of justice of deprives of liberty.
- Patient in situation of emergency
Perprocedure exclusion criteria
• Patient in need of the balloon during the navigation will be excluded of the study (Experimental group)
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:EUS with EZ-EUS navigation system
EUS with the experimental navigation system |
Use of the EZ-EUS navigation system during the procedure |
|
无干预:Standard EUS
EUS in standard condition |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Evaluation of the EUS navigation system's procedure duration compared to standard procedure times
大体时间:1 day
|
Comparison of the examination period duration between the two groups (experimental vs control) |
1 day
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Assessment of the EUS navigation system for patient safety
大体时间:1 month
|
Rate of adverse events, adverse device effects and complications |
1 month
|
|
Assessment of the system's ease-of-use and technological maturity
大体时间:1 day
|
Qualitative assessment of the system's ease-of-use and technological maturity using questionnaires. Appropriate statistical test will be used to compare each procedure. Results will be presented numerically and graphically. |
1 day
|
|
Assessment of the EUS navigation system for reliability
大体时间:1 day
|
Rate of device deficiencies during the procedure |
1 day
|
|
Evaluation of the time required to perform individual step duration
大体时间:1 day
|
Comparison of the duration of each individual step |
1 day
|
|
Recording of procedure data for offline systeme performance assessment
大体时间:1 day
|
Collection and prospective review of EUS data, including video and electromagnetic coordinates provided by the sensor |
1 day
|
|
Assessment of the registration method
大体时间:1 day
|
Quantitative (numerical) assessment of registration accuracy using Target Registration Error (TRE), defined as the distance between the predicted 3D location of an anatomical landmark by the navigation system and its true 3D location |
1 day
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.