使用基于透射的微波扫描仪对乳房植入物进行成像的可行性

2026年11月16日 更新者:Elise Fear、University of Calgary

基于透射式扫描仪对乳房植入物进行成像的可行性

The goal of this clinical trial is to assess whether microwave scans can depict the presence of implants in the breast in women with existing breast implants that were surgically placed at least 6 months ago. The main questions it aims to answer are:

  1. Can a microwave imaging device effectively scan a breast containing implants?
  2. Can the presence of implants be identified in a microwave scan?
  3. Can the microwave scans of the left and right breasts be compared to assess whether similarity is observed?

研究概览

地位

尚未招聘

详细说明

Breast implants are consistently one of the top 5 cosmetic procedures performed each year in North America. The Food and Drug Administration (FDA) cites a 10% risk of rupture over 10 years (1% cumulative per annum risk of device rupture).

Rupture refers to disruption in the integrity of the implant, and is typically age-related deterioration where age in this context refer to the implant. Rupture in saline implants is detected with rapid change in breast size. With silicone implants, rupture is much more challenging to detect as it is rare to have a completely collapsed implant shell.

Current recommendations for surveillance of breast implants include Magnetic Resonance Imaging (MRI) or ultrasound within 5-6 years of surgery for the initial test, then every 2-3 years. The guideline initially included only MRI but was adjusted in 2022 to include ultrasound. Patient adherence to guidelines with only MRI was very low (less than 5%), which is postulated to relate to the expense, discomfort, and inaccessibility of MRI. Mammography is a frequently used breast imaging method. However, the majority of women with implants are too young for breast screening programs that involve regular mammograms. Also, the implant is displaced during mammography to focus on the breast tissues. Finally, mammography involves exposure to x-rays, limiting regular scans in women too young for screening.

Therefore, there is a need to regularly inspect silicone implants for silent rupture. An imaging approach that is low-cost, available at point-of-care, easy to use, and reliable (i.e. sensitive to implant rupture) would be a valuable tool for plastic surgery clinics.

Microwave imaging has been proposed as a low-cost and comfortable approach to breast imaging that can be performed at point of care. This approach to imaging is low power, so no tissue heating occurs and there are no other side effects. Therefore, microwave imaging is suited to in-clinic, ongoing monitoring of the breast.

10 women with breast implants will be recruited from plastic surgery clinics. This includes women with breast implants that were surgically placed at least 6 months prior and are asymptomatic for implant rupture, as well as women who have implants with a confirmed rupture. Study participants will be scanned with the microwave imaging system. Three scans of each breast will be collected in each of the Craniocaudal (CC) and Mediolateral Oblique (MLO) views.

The breast positioning will be adjusted between scans to maximize the presentation of the implant in the imaging volume. The images will be analyzed to identify the implants, as the implants have different properties when compared to healthy breast tissues.

研究类型

介入性

注册 (估计的)

10

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

    • Alberta
      • Calgary、Alberta、加拿大、T3H 3K8

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

女性

描述

Inclusion Criteria:

  • Women with breast implants placed at least 6 months prior who are asymptomatic for implant rupture as well as those with known implant rupture
  • Female
  • Minimum of 18 years of age
  • Able to provide informed consent

Exclusion Criteria:

  • Women who are currently pregnant or breastfeeding
  • Women with active breast infections
  • Women with nipple piercings (unless removed prior to scanning)
  • Women with implanted electronic device
  • Women with physical limitations that prevent them from placing their breasts inside the scanner

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:A single arm study to determine feasibility of imaging breast implants

WVI-MIS-03-2025

Microwave scans

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Measurement of regions of interest in microwave images
大体时间:12 months

Images of both breasts will be created. Regions of interest corresponding to the breast implants will be identified using the electrical properties. The size of these regions will be calculated.

12 months

次要结果测量

结果测量
措施说明
大体时间
Comparison of total area in implant in microwave image with known physical size
大体时间:12 months

The total area corresponding to the breast implant in the microwave images will be calculated and compared with the known implant size.

12 months
Compare microwave scans of the left and right breast
大体时间:12 months

The properties and size of the region corresponding to the implant will be compared between right and left breasts.

12 months

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年12月1日

初级完成 (估计的)

2026年12月30日

研究完成 (估计的)

2026年12月30日

研究注册日期

首次提交

2026年3月17日

首先提交符合 QC 标准的

2026年3月17日

首次发布 (实际的)

2026年3月23日

研究记录更新

最后更新发布 (实际的)

2026年11月18日

上次提交的符合 QC 标准的更新

2026年11月16日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

其他研究编号

  • REB25-0914

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅