低流量与高流量麻醉对颅内压的影响
高流量与低流量麻醉对腹腔镜子宫切除术中视神经鞘直径和脑氧合的对比影响
This prospective randomized study was conducted to evaluate the effects of low-flow and high-flow anesthesia on intracranial dynamics and cerebral oxygenation in patients undergoing laparoscopic hysterectomy in the Trendelenburg position. Intracranial pressure was assessed noninvasively using optic nerve sheath diameter (ONSD), and cerebral oxygenation was monitored using near-infrared spectroscopy (NIRS). Changes in these parameters were assessed under standardized pneumoperitoneum and positioning conditions, and comparisons between anesthesia flow groups were performed according to the predefined study protocol.
研究概览
地位
详细说明
Laparoscopic surgical procedures commonly involve the establishment of pneumoperitoneum (PP) and the application of the Trendelenburg position (TP) to optimize surgical exposure. These interventions are known to increase intra-abdominal pressure and may influence venous return, intrathoracic pressure, and cerebral hemodynamics. The combined use of pneumoperitoneum and Trendelenburg positioning is considered to have the potential to increase intracranial pressure (ICP). Therefore, the intraoperative assessment of intracranial dynamics is of clinical importance.
Optic nerve sheath diameter (ONSD) measurement is a noninvasive, reproducible, and bedside-applicable method used to assess changes in intracranial pressure. ONSD is considered to correlate with ICP alterations. Cerebral oxygenation can be evaluated using near-infrared spectroscopy (NIRS), a noninvasive technique that enables continuous monitoring of cerebral tissue oxygenation.
Low-flow anesthesia is based on the reduction of fresh gas flow rates and offers several advantages, including decreased anesthetic gas consumption, preservation of heat and humidity in the respiratory tract, and reduced environmental impact. However, data regarding the effects of low-flow anesthesia on cerebral physiology and intracranial dynamics remain limited. In surgical settings where pneumoperitoneum and Trendelenburg positioning are applied, evaluating the impact of different fresh gas flow rates on intracranial pressure and cerebral oxygenation is particularly important.
This prospective, randomized study was conducted in patients scheduled for elective laparoscopic hysterectomy at Bursa City Hospital. Patients aged between 18 and 75 years with an American Society of Anesthesiologists (ASA) physical status of I-II were included. Patients meeting predefined exclusion criteria were not enrolled in the study. Written informed consent was obtained from all participants prior to inclusion.
Patients were randomized into two groups using the closed-envelope method to receive either low-flow or high-flow anesthesia. Standard monitoring, including electrocardiography, noninvasive blood pressure, peripheral oxygen saturation, and NIRS monitoring, was applied to all patients. General anesthesia induction and maintenance were performed according to standardized protocols. Mechanical ventilation was provided in volume-controlled mode, and ventilator parameters were maintained within standard ranges.
Pneumoperitoneum was established using carbon dioxide (CO₂) insufflation at a predefined pressure range and was maintained throughout the surgical procedure. Following the establishment of pneumoperitoneum, patients were placed in the Trendelenburg position at a predefined angle, which was maintained during the operation.
Optic nerve sheath diameter measurements were performed using ultrasonography with minimal pressure applied to the globe. Measurements were obtained at predefined time points. Cerebral oxygenation was continuously monitored using NIRS throughout the intraoperative period. In addition, hemodynamic and respiratory parameters, including heart rate, arterial blood pressure, end-tidal carbon dioxide (EtCO₂), and ventilatory variables, were recorded.
Within the scope of this study, the effects of low-flow and high-flow anesthesia on intracranial dynamics and cerebral oxygenation were planned to be comparatively evaluated, and the study was conducted in accordance with the predefined protocol.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Bursa、土耳其(türkiye)、16110
- Bursa City Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria
- Female patients aged 18-75 years
- Scheduled for elective laparoscopic hysterectomy
- American Society of Anesthesiologists (ASA) physical status I-II
- Ability to provide written informed consent
Exclusion Criteria
- Septicemia
- Risk of malignant hyperthermia
- Uncontrolled diabetes mellitus
- Chronic alcohol use
- Prolonged fasting
- Body mass index (BMI) > 40 kg/m²
- Intracranial space-occupying lesions (e.g., tumors, metastases, abscesses, hematomas, aneurysms)
- History of head trauma or cerebrovascular stroke within the preceding six months
- Known heart failure
- Diagnosis of glaucoma
- Prior carotid surgery or carotid artery stenosis
- ASA physical status ≥ III
- Requirement for massive blood transfusion
- Conversion from volume-controlled to pressure-controlled mechanical ventilation during surgery
- Intraoperative conversion to open surgery
- Patient refusal to participate
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:LOW-FLOW ANESTHESİA
Patients in this group received general anesthesia with sevoflurane. Fresh gas flow was initially set at 3 L/min until a minimum alveolar concentration (MAC) of 1.0 was achieved, after which it was reduced to 1 L/min and maintained throughout the procedure. |
Patients assigned to the low-flow anesthesia group initially received a fresh gas flow of 3 L/min with a mixture of 50% oxygen and 50% air until a minimum alveolar concentration (MAC) of 1.0 was achieved. Subsequently, the fresh gas flow was reduced to 1 L/min, with oxygen and air concentrations maintained at 50-60% and 40-50%, respectively. Anesthesia was maintained with sevoflurane and a continuous remifentanil infusion. |
|
实验性的:HIGH-FLOW ANESTESIA
Patients assigned to the high-flow anesthesia group received general anesthesia with sevoflurane using a fresh gas flow rate of 3 L/min throughout the procedure. A gas mixture consisting of 50% oxygen and 50% air was administered, with a target minimum alveolar concentration (MAC) of 1.0. Remifentanil was administered as a continuous intravenous infusion at 0.05-0.1 μg/kg/min |
Patients assigned to the high-flow anesthesia group received a fresh gas flow of 3 L/min throughout the procedure, using a mixture of 50% oxygen and 50% air. Anesthesia was maintained with sevoflurane at a target minimum alveolar concentration (MAC) of 1.0, together with a continuous remifentanil infusion. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Optic Nerve Sheath Diameter
大体时间:1-4 hour
|
To determine the differences between the two groups of trendelenburg and pneumoperitoneum, which increase intracranial pressure. |
1-4 hour
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Cerebral Oxygenation
大体时间:1-4 hour
|
To determine the effects of low-flow and high-flow anesthesia on cerebral oxygenation in conditions that increase intracranial pressure. |
1-4 hour
|
合作者和调查者
出版物和有用的链接
一般刊物
- Ishiyama T, Kotoda M, Asano N, Ikemoto K, Shintani N, Matsuoka T, Matsukawa T. Effects of hyperventilation on cerebral oxygen saturation estimated using near-infrared spectroscopy: A randomised comparison between propofol and sevoflurane anaesthesia. Eur J Anaesthesiol. 2016 Dec;33(12):929-935. doi: 10.1097/EJA.0000000000000507.
- Mermer A, Kozanhan B. Comparison of the effects of low-flow and normal-flow anesthesia on intracranial pressure, cerebral oxygenation and bispectral index in laparoscopic cholecystectomy operation. Eur Rev Med Pharmacol Sci. 2023 Sep;27(18):8514-8522. doi: 10.26355/eurrev_202309_33776.
- Hanel F, Blobner M, Bogdanski R, Werner C. Effects of carbon dioxide pneumoperitoneum on cerebral hemodynamics in pigs. J Neurosurg Anesthesiol. 2001 Jul;13(3):222-6. doi: 10.1097/00008506-200107000-00007.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 2023-17/2
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
Protecting patient privacy and ensuring the security of patient personal information is paramount. However, in our study, some data can be shared without compromising patient safety.
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.