Prospective S&E Study of Wavefront-guided PRK for Myopia With iDesign Advanced Wavescan Studio™ System and Star S4 IR™
A Prospective Study to Evaluate the Safety and Effectiveness of Wavefront-guided PRK Correction of Myopic Refractive Errors With the iDesign Advanced Wavescan Studio™ System and the Star S4 IR™ Excimer Laser System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
California
-
Camp Pendleton, California, United States, 92055
- Naval Hospital Camp Pendleton
-
San Diego, California, United States, 92106
- Naval Medical Center
-
-
Maryland
-
Andrews Air Force Base, Maryland, United States, 20762
- Warfighter Eye Center Malcolm Grow Medical Clinics and Surgery Center
-
-
North Carolina
-
Camp Lejeune, North Carolina, United States, 28547
- Naval Hospital Camp Lejeune
-
-
Texas
-
El Paso, Texas, United States, 79920
- William Beaumont Army Medical Center
-
Lackland Air Force Base, Texas, United States, 78236
- Joint Warfighter Refractive Surgery Center Wilford Hall Medical Center
-
-
Virginia
-
Portsmouth, Virginia, United States, 23708
- Naval Medical Center Portsmouth
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
NOTE: Enrollment open only to military personnel
Inclusion Criteria:
- Signed informed consent and HIPAA authorization.
- Refractive error, based on the iDesign displayed refraction must be myopia with or without astigmatism with sphere up to -8.00 D, and cylinder between 0.00 D and -4.00 D with maximum SE of -10.00 D.
- Anticipated residual stromal bed thickness of at least 250 microns as calculated by the iDesign system.
- Distance Best Spectacle Corrected Visual Acuity (BSCVA) of 20/20 or better
- BSCVA ≥2 lines (≥10 letters) better than distance Uncorrected Visual Acuity (UCVA).
- Less than or equal to 0.75 D difference between cycloplegic and manifest refraction sphere.
- Stable refractive error as defined by a change of ≤1.00 D in MRSE over at least a 12 month time period.
- Any subject eye with a history of contact lens wear within the last 4 weeks must demonstrate refractive stability
- Agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction chosen for treatment.
- Willing and capable of complying with follow-up examinations for the duration of the study.
Exclusion Criteria:
- Women who are pregnant, breast-feeding, or intend to become pregnant, or not using an adequate method of birth control.
- Concurrent use of systemic (including inhaled) medications that may impair healing.
- History of any of the following medical conditions, or any other condition that could affect wound healing: collagen vascular disease, autoimmune disease, immunodeficiency diseases, ocular herpes zoster or herpes simplex, endocrine disorders (including, but not limited to unstable thyroid disorders and diabetes), lupus, and rheumatoid arthritis.
- Subjects with a cardiac pacemaker, implanted defibrillator or other implanted electronic device.
- History of prior intraocular or corneal surgery, active ophthalmic disease or abnormality, retinal detachment/repair, clinically significant lens opacity, clinical evidence of trauma, corneal opacity within the central 9 mm and visible on topography, at risk for developing strabismus, or with evidence of glaucoma or propensity for narrow angle glaucoma.
- Evidence of keratoconus, corneal dystrophy or irregularity, or abnormal topography
- Known sensitivity or inappropriate responsiveness to any of the medications used in this study.
- If either eye does not meet all inclusion criteria
- Desire to have monovision.
- Participation in any other clinical study, with the exception of the fellow eye in this study.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: wavefront-guided PRK with iDesign
wavefront-guided PRK for treatment of myopic refractive errors based upon measurements obtained with the iDesign System using the STAR S4 IR laser
|
Surgeons will perform wavefront-guided PRK for the treatment of myopic refractive errors based upon measurements obtained with the iDesign System using the STAR S4 IR laser.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The Percentage of Eyes Achieving the Target of Monocular Uncorrected Visual Acuity of 20/40 or Better
Time Frame: 6 months
|
At 6 months, UCVA of 20/40 was achieved in 100% (324/324) of eyes monocularly.
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Johnson & Johnson Surgical Vision Clinical Trials, Johnson & Johnson Surgical Vision, Inc.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- STAR-115-MIPS
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Stable Myopic Refractive Error, With or Without Astigmatism
-
NCT02103309CompletedRefractive Error | Myopia | Myopic Astigmatism
-
NCT07478419CompletedMyopia | Myopic Astigmatism | Refractive Error - Myopia Axial
-
NCT04710082CompletedMyopia ≤ -6 Diopters or Myopic Astigmatism ≤ -4 Diopters
-
NCT04614948CompletedParticipants With or Without Stable Co-morbidities Associated With Progression to Severe COVID-19
-
NCT04505722CompletedParticipants With or Without Stable Co-morbidities Associated With Progression to Severe COVID-19 at Different Stages of the Protocol
-
NCT02204449CompletedCoronary Artery Disease | Acute Coronary Syndrome | Percutaneous Coronary Intervention | Chronic Stable Heart Failure | Coronary Artery Bypass Graft Surgery, With or Without Valve Surgery
Clinical Trials on STAR S4 IR laser with iDesign
-
NCT04075591Completed
-
NCT01061294Completed
-
NCT01454843Completed
-
NCT06021353Completed