Wavefront-guided LASIK for Monovision Treatment of Myopic Subjects With Presbyopia
Post-approval Study of Wavefront-guided LASIK for Monovision Treatment of Myopic Subjects With Presbyopia
Study Overview
Status
Conditions
Intervention / Treatment
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
California
-
Los Angeles, California, United States, 90024
- Maloney Vision Institute
-
-
Illinois
-
Chicago, Illinois, United States, 60602
- Kraff Eye Institute
-
-
Nevada
-
Las Vegas, Nevada, United States, 89145
- Center for Sight
-
-
New Mexico
-
Albuquerque, New Mexico, United States, 87109
- Coleman Vision
-
-
South Dakota
-
Sioux Falls, South Dakota, United States, 57108
- Vance Thompson Vision
-
-
Tennessee
-
Goodlettsville, Tennessee, United States, 37072
- Loden Vision Centers
-
-
Texas
-
Houston, Texas, United States, 77027
- Berkeley Eye Institute, P.A.
-
Hurst, Texas, United States, 76054
- Texas Eye & Laser Center
-
-
Utah
-
Ogden, Utah, United States, 84403
- Utah Eye Center
-
-
Virginia
-
Fairfax, Virginia, United States, 22031
- The Eye Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Signed informed consent and HIPAA authorization.
- At least 40 years of age at enrollment (date informed consent signed).
- The refractive error of both subject's eyes, based on the iDesign refraction selected for treatment ("4.0 mm Rx calc" at 12.5 mm), must be myopic with or without astigmatism up to -6.00 D spherical equivalent (SE), with cylinder up to -3.00 D and minimum pre-operative myopia in their non-dominant eye at least as great as their targeted myopic retention.
- At least one eye must require a myopic treatment.
- Anticipated stromal bed thickness of at least 250 microns based on preoperative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign plus the intended flap thickness).
- Distance Best Spectacle Corrected Visual Acuity (BSCVA) of 20/20 or better.
- Require an add power of +1.25 D or more but not greater than +2.00 D at 40 cm.
- Less than or equal to ±0.50 D difference between cycloplegic and manifest refraction sphere.
A stable refractive error (based on a previous exam, medical records, lensometry, or prescription that is at least 12 months prior to the preoperative manifest refraction), as defined by a change of less than or equal to
- 0.50 D in MRSE (sphere and cylinder).
Subjects with a history of contact lens wear within the last 4 weeks must discontinue lens wear in order to demonstrate refractive stability according to the following (refractive stability is defined as a change of not more than 0.50 D in manifest refraction sphere and cylinder as well as mean keratometry between measurements): After the Informed Consent process has been completed and subjects are enrolled in the study:
- Rigid or extended wear contact lenses (toric or spherical) must be removed for at least 3 weeks and soft contact lenses (toric or spherical) for at least 2 weeks prior to the first refraction used to establish stability.
- After abstaining from contact lens wear for designated time, two consecutive manifest refractions and keratometric readings must be conducted at least 7 days apart
- I If the subject/eye meets the refractive stability criteria, contact lens wear is not permitted for 2 weeks prior to surgery except as required to test monovision acceptance as described below in the Study Procedures, Contact Lens Trial section NOTE: Refractive stability needs to be confirmed only once during preoperative assessment
Agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction chosen for treatment, as follows:
- Spherical Equivalent: magnitude of the difference is less than 0.625 D.
- Cylinder: magnitude of the difference is less than or equal to 0.5 D.
- Cylinder Axis Tolerance: If either the manifest cylinder entered into the iDesign System or the iDesign cylinder selected for treatment is less than 0.5 D, there is no requirement for axis agreement. When both cylinders have a magnitude of at least 0.5 D, the axis tolerance as determined by the iDesign system is linearly reduced from 15 degrees (0.5 D) to 7.5 degrees (7.0 D) based on the average magnitude of both cylinders. Note: If the axis tolerance is not in the calculated range, the iDesign system will produce a warning and this exam may not be used for treatment planning.
- Willing and capable of complying with follow-up examinations for the duration of the study.
Exclusion Criteria:
Women who are pregnant, breast-feeding, or intend to become pregnant during the study.
Note: Women who were pregnant or nursing may not be enrolled until 6 months after either delivery or have stopped nursing and there is documented refractive stability.
- Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: antimetabolites, isotretinoin (Accutane®) within 6 months of treatment, and amiodarone hydrochloride (Cordarone®) within 12 months of treatment. NOTE: The use of inhaled or systemic corticosteroids, whether chronic or acute, within the past 6 months is deemed to adversely affect healing and subjects using such medications are specifically excluded from eligibility.
History of any of the following medical conditions, or any other condition that could affect wound healing: collagen vascular disease, autoimmune disease, immunodeficiency diseases, ocular herpes zoster or herpes simplex, endocrine disorders (including, but not limited to unstable thyroid disorders and diabetes), lupus, and rheumatoid arthritis.
NOTE: The presence of diabetes (either type 1 or 2), regardless of disease duration, severity, or control, will specifically exclude subjects from eligibility.
- Subjects with a cardiac pacemaker, implanted defibrillator or other implanted electronic device.
History of prior intraocular or corneal surgery (including cataract extraction), active ophthalmic disease or abnormality (including, but not limited to, symptomatic blepharitis, recurrent corneal erosion, dry eye syndrome, neovascularization > 1 mm from limbus), retinal detachment/repair, clinically significant lens opacity, clinical evidence of trauma, corneal opacity within the central 9 mm and visible on topography, prior strabismus surgery, strabismus, or at risk for developing strabismus, or with evidence of glaucoma or propensity for narrow angle glaucoma or suspected glaucoma.
NOTE: Subjects with glaucoma, regardless of medication regimen or control, or an IOP greater than 21 mmHg at screening, are specifically excluded from eligibility.
- Evidence of keratoconus, corneal dystrophy or irregularity, or abnormal topography.
- Known sensitivity or inappropriate responsiveness to any of the medications used in the postoperative course.
- Intolerance to monovision correction based on questionnaire responses to contact lens trial (refer to section Study Procedures, Contact Lens Trial below).
- Concurrent participation in any other clinical trial, or participation in any other clinical trial within the last 14 days.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Wavefront-guided Lasik Monovision Treatment
Wavefront-guided LASIK monovision treatment of myopic subjects with presbyopia using the STAR S4 IR® Excimer laser System with the iDesign Refractive Studio.
|
Surgeons will perform wavefront-guided monovision LASIK for the treatment of myopic subjects with presbyopia based upon measurements obtained with an iDesign Refractive Studio.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The change in driving scale score from preoperative to postoperative as measured by the driving scale within the PROWL-M (Patient-Reported Outcomes with LASIK for monovision) questionnaire
Time Frame: 12 months
|
To assess the effect of monovision LASIK treatment on difficulty with driving as measured by the driving scale within the PROWL-M (Patient-Reported Outcomes with LASIK for monovision) questionnaire
|
12 months
|
|
The proportion of subjects who required secondary surgery to reverse monovision
Time Frame: 12 months
|
The proportion of subjects who required secondary surgery to reverse monovision will be reported.
|
12 months
|
Collaborators and Investigators
Sponsor
Investigators
- Study Director: AMO Development, LLC Clinical Trial, AMO Development, LLC
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- STAR-122-MVPM
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Refractive Error
-
Alcon ResearchCompletedRefractive Error - Myopia Severe | Refractive Error - Myopia SimpleUnited States, Ireland, Singapore
-
Johnson & Johnson Vision Care, Inc.TerminatedRefractive Error CorrectionUnited States
-
Vision Service PlanCompletedRefractive Error - Myopia BilateralUnited States
-
Vision Service PlanCompletedRefractive Error - Myopia BilateralUnited States
-
Wang HongxiaTianjin Eye HospitalCompletedRefractive Error - Myopia AxialChina
-
KK Women's and Children's HospitalWithdrawnRefractive Error - Myopia
-
Tianjin Eye HospitalRecruitingMyopia; Refractive ErrorChina
-
Myoptechs, IncUniversity of Waterloo School of Optometry and Vision ScienceNot yet recruitingMyopia: Refractive Error
-
Perfect Lens, LLCCompletedRefractive Error CorrectionPanama
-
Essilor InternationalRecruitingRefractive Error | AmetropiaUnited States
Clinical Trials on iDesign Refractive Studio with STAR S4 IR® Excimer laser System
-
59th Medical WingUnited States Army Aeromedical Research LaboratoryActive, not recruiting
-
Abbott Medical OpticsCompletedStable Myopic Refractive Error, With or Without AstigmatismUnited States
-
Innovative MedicalCompletedVision CorrectionUnited States