Prospective Analysis of Value of Contrast-enhanced Sonography During Biopsies of Focal Liver Masses

July 24, 2019 updated by: Jordan K. Swensson, Indiana University
The investigators plan to compare complication and success rates between two methods of ultrasound guidance for biopsy of liver lesions, contrast-enhanced and the current protocol without contrast.

Study Overview

Status

Terminated

Conditions

Intervention / Treatment

Detailed Description

As a major oncology and hepatology center, the investigators perform about 3-5 guided biopsies for liver tumors weekly. Ultrasound is the preferred modality for imaging biopsies due to its ability to visualize and position the biopsy needle in real time with high accuracy and safety, is nonionizing, and is quicker compared to other techniques, especially CT-guided biopsies. The failure rate of ultrasound guided liver biopsies (including cases where biopsy was declined to be performed due to lack of lesion visibility) is about 10%. By comparison, in the investigators' practice genotyping of metastatic tumors, with multiple core biopsies, is often requested for entry into oncology trials, and failure of tumor genotyping after biopsy is estimated to be about 30%.

Recently, the first ultrasound contrast agent was FDA-approved for characterization of liver lesions [sulfur hexafluoride lipid-type A microspheres (Lumason, Bracco Diagnostics, Monroe Township, NJ)]. The microbubble agent is deemed safe, including in cardiac failure patients and those with chronic airway obstruction. Injecting microbubbles may allow better visualization of lesions and adjacent vasculature by enhancing the microvasculature and adjacent vessels and potentially reduce incidence of failed biopsy or bleeding complications. In addition, determination of necrotic regions in a lesion may allow better direction of biopsy.

Yet there is limited literature on the use of ultrasound contrast agents for improving targeted liver biopsies. The investigators intend to prospectively assess the non-diagnostic biopsy and complication rates in a group of patients who undergo contrast-enhanced ultrasonography (CEUS) using microbubbles at the time of biopsy. The investigators will then compare the results from this group with the failure and complication rate from a control group of patients undergoing the standard US-guided biopsy procedure. Over 12 months the investigators expect to perform approximately 200 biopsies. Power analysis suggests that 125 patients in both contrast-enhanced sonography and control groups, each, are required. The investigators should be able to enroll sufficient patients in 18 months

Study Type

Interventional

Enrollment (Actual)

83

Phase

  • Phase 4

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Indiana
      • Indianapolis, Indiana, United States, 46202
        • Indiana University Health

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Males and females
  2. Age 18 years or greater
  3. Scheduled to undergo liver biopsy with ultrasound guidance at a performance site

Exclusion Criteria:

  1. Liver biopsy is not intended to obtain tissue from a specific lesion
  2. Known or suspected cardiac shunt
  3. History of hypersensitivity to any active or inactive ingredients in Lumason

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: Non-Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: biopsy with Lumason
liver biopsy performed with prior contrast enhancement with Lumason 60.7Mg Powder for Injection (experimental method)
Lumason 60.7Mg Powder for Injection injected prior to ultrasound-guided biopsy
Other Names:
  • Lumason
Placebo Comparator: biopsy with placebos
liver biopsy performed without prior contrast enhancement (standard method)
Placebos injected prior to ultrasound-guided biopsy

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Complication Rate
Time Frame: 30 days
Complication will be defined as 1) bleeding seen on post-biopsy CT or US, 2) drop in hemoglobin of more than 1.5 g/dL within one week after biopsy, or 3) need for hepatic artery embolization.
30 days

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Success Rate
Time Frame: 30 days
Biopsy sample being sufficient for histological diagnosis and/or complete genotyping.
30 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Kumar Sandrasegaran, MD, Indiana University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 22, 2016

Primary Completion (Actual)

June 30, 2018

Study Completion (Actual)

July 6, 2018

Study Registration Dates

First Submitted

January 31, 2017

First Submitted That Met QC Criteria

January 31, 2017

First Posted (Estimate)

February 2, 2017

Study Record Updates

Last Update Posted (Actual)

August 8, 2019

Last Update Submitted That Met QC Criteria

July 24, 2019

Last Verified

July 1, 2019

More Information

Terms related to this study

Other Study ID Numbers

  • 1609504711

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

Yes

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Liver Biopsy

Clinical Trials on Lumason 60.7Mg Powder for Injection

Search Similar Trials