Accuracy of Computer Guided Surgery (vs) Conventional Model Surgery in Treatment of Skeletal Open Bite
Accuracy of Computer Guided Surgery (vs) Conventional Model Surgery in Treatment of Skeletal Open Bite: A Randomized Clinical Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
P Adult Patients with skeletal open bite.
I Computer guided surgery.
C Conventional articulating model surgery
O Outcome measure:
Outcome Name Measuring Device Measuring Unit (mm)
O1 Accuracy
Computer guided: Super-imposition of virtual surgery over the post- operative CT Scan composite models ( millimeter mm)
Conventional : Super-imposition of scanned articulator with mounted casts in the pre-planned mock surgery over post-operative scanned mounted occlusion ( millimeter mm)
O2 Anterior open Bite Closure
Standardized Multi Scan CT (millimeter mm)
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Ammar R Abu Shama, PHD
- Phone Number: 00201142354052
- Email: Dr.ammar.shama@gmail.com
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients suffering from skeletal open bite caused by vertical posterior maxillary excess and/or short mandible ramus.
- Patients should be free from any systemic disease that may affect normal healing, and predictable outcome.
- Required two jaws orthographic surgery
Exclusion Criteria:
- Patients with any systemic disease that may affect normal healing
- Intra-bony lesions or infections that may retard the osteotomy healing.
- Patient with bad oral hygiene.
- Uncontrolled Diabetes mellitus.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: SINGLE_GROUP
- Masking: DOUBLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Conventional Model Surgery
Lateral Cephalogram with analysis and tracing of facial profile. Modified model surgical tecnique:
|
preparation for orthognathic surgery which involves diagnosis with 2D cephalometric radiograph, face-bow transfer and model surgery on plaster dental cast, and fabrication of intermediate and final occlusal splint.
2D cephalometric radiograph
|
|
EXPERIMENTAL: Computer guided surgery
Preoperative surgical simulation and immediate postoperative evaluation will be carried out using Multi Slice CT scan. Computer-aided planning for study group: All planning will be done using specialized software (Anatomage Invivo 5.3) for preoperative surgical simulation and immediate postoperative evaluation. Pre-operative Fabrication of computer aided surgical splint: In the study group a stereo splint will be fabricated using rapid prototyping (RP) technique to guide the osteotomy and another one will be fabricated after virtual osteotomy to guide the surgical cuts. And stent for guided holes. So that the osteotomy will be accomplished by the aid of computer guided templates that simulates the proper bite achieved preoperatively during surgical simulation and Planning. |
Preoperative surgical simulation and immediate postoperative evaluation will be carried out using Multi Slice CT scan.Craniofacial images from 3D computerized tomography (3D-CT scan) can be used to create a 3D model, which can in turn be used for 3D Cephalometry measurements and surgical simulation.The process of 3D-model contains mounting of 3D virtual models in a 3D virtual articulator; and repositioning of 3D virtual models according to the STO then Fabrication of a 3D virtual intermediate surgical wafer; and materialization of the surgical wafer using a stereolithographic technique.
The 3D model can produce actual movement of surgical cuts and movement of segments accordingly
3D computerized tomography
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of movement of surgical segments in millimeter
Time Frame: up to 4 months
|
Computer guided Super-imposition of virtual surgery over the post- operative CT Scan composite models (millimeter mm). Conventional Super-imposition of scanned articulator with mounted casts in the pre-planned mock surgery over post-operative scanned mounted occlusion- accuracy would be compared by difference between Intervention and control in (millimeter mm). |
up to 4 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Anterior open Bite Closure (positive overbite in millimeter)
Time Frame: up to 4 months
|
Standardized pre-surgery movement in amount of anterior open bite closure (mm) will be determined clinically and by radiograph.
|
up to 4 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Moustafa K Ezz, Professor, Cairo university
Study record dates
Study Major Dates
Study Start (ANTICIPATED)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 292017
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Conventional model surgery
-
NCT06674499Active, not recruitingHead and Neck Cancer | Rehabilitation | Psychotherapy
-
NCT03256513UnknownCerebral Revascularization | Ischemic Cerebrovascular Disease
-
NCT04806360Not yet recruitingDegenerative Cervical Kyphosis With Stenosis
-
NCT06971653Completed
-
NCT02942108Completed
-
NCT00007930Unknown
-
NCT06541288Not yet recruiting
-
NCT06622421Not yet recruitingOsteonecrosis of the Jaw | Bisphosphonate-Associated Osteonecrosis of the Jaw | Osteonecrosis Due to Drug
-
NCT06965855Completed
-
NCT06018246CompletedGastrointestinal Cancer