Influence of Tracheal-bronchial Anatomy Changes on Multi-detector Computed Tomography Scan of the Chest Upon Placement of Left-Sided Double Lumen Endotracheal Tube
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Iowa
-
Iowa City, Iowa, United States, 52242
- University of Iowa Hospitals & Clinics
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- At least 18 years of age
- Adult patient undergoing scheduled thoracic surgery which requires left side double lumen tube placement
Exclusion Criteria:
- More than 90 years of age
- Patients with emergency surgery
- Prisoners
- Patients who cannot provide their own consent
- Patient refusal
- Non-English speaking patients
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
Left main bronchus (LMB) intubation
Thoracic surgery patient is intubated with left side double lumen tube (L-DLT) and a fiberoptic bronchoscope is used to verify optimal positioning.
The patient is designated as this group when the endobronchial lumen is observed to be in the left main bronchus (correct placement).
|
|
Right main bronchus (RMB) intubation
Thoracic surgery patient is intubated with left side double lumen tube (L-DLT) and a fiberoptic bronchoscope is used to verify optimal positioning.
The patient is designated as this group when the endobronchial lumen is observed to be in the right main bronchus (incorrect placement).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measure tracheal length (mm) derived from MDCT images
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
Tracheal length as seen on MDCT images will be measured (millimeters) and compared between the two groups.
|
Within 1 month
|
|
Measure LMB diameter (mm) derived from MDCT images
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
The LMB as seen on MDCT images will be measured (millimeters) and compared between the two groups.
|
Within 1 month
|
|
Measure RMB diameter (mm) derived from MDCT images
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
The RMB as seen on MDCT images will be measured (millimeters) and compared between the two groups.
|
Within 1 month
|
|
Measure the tracheal LMB curvature (TLMBC) derived from MDCT images
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
The TLMBC as seen on MDCT images will be measured and compared between the two groups.
TLMBC is measured at the Trachea LMB branch point.
The center lines of the airway segments (trachea and LMB) close to the branch point are displayed.
A circumscribed circle goes through three adjacent airway points centered at the branch point is produced and the curvature is calculated by the reciprocal of the circle radius.
The curvature of a straight line is zero.
A larger curvature indicates a sharper turning angle.
|
Within 1 month
|
|
Measure the tracheal RMB curvature (TRMBC) derived from MDCT images
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
The TRMBC as seen on MDCT images will be measured and compared between the two groups.
TRMBC is measured at the Trachea LMB branch point.
The center lines of the airway segments (trachea and RMB) close to the branch point are displayed.
A circumscribed circle goes through three adjacent airway points centered at the branch point is produced and the curvature is calculated by the reciprocal of the circle radius.
The curvature of a straight line is zero.
A larger curvature indicates a sharper turning angle.
|
Within 1 month
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Calculate the TLMBC/TRMBC (TLMB/TRMB) Curvature Ratio
Time Frame: Within 1 month
|
Participants are divided into two groups based upon the first pass location of the L-DLT; LMB (left main bronchus) intubation group and RMB (right main bronchus) intubation group.
A ratio of the TLMBC and TRMBC values reported above will be calculated and compared between the two groups.
|
Within 1 month
|
|
Incidence of the DLT misplacement (RMB intubation) at the fast pass
Time Frame: Within 10 minutes
|
The number of times DLT misplacement (RMB intubation) at the first pass will be recorded.
|
Within 10 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Javier H Campos, MD, University of Iowa
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 201207717
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.