Ventil Device Usefulness in Mechanically Ventilated ICU Patients
Assesment of Usefulness of Ventil Device for Mechanical Ventilation in ICU Patients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
During Covid-19 pandemic many patients require mechanical ventilation due to disastrous impact of SARS-CoV-2 on lungs. In several countries there is a shortage of ICU beds and ventilators. Critically ill patients are treated outside ICUs. Doctors are facing ethical dilemmas who they should treat with ventilation, who should receive ventilator and who should but will not.
Before pandemic in ICUs there had always been patients who required mechanical ventilation because of extrapulmonary reasons as well as palliative cases or those in vegetative condition. Most of these patients require just a simple ventilator, not a sophisticated mode of ventilation. Some attempts to invent a device that could replace complex machines in patients with anticipated poor outcome have been made. Ventil was used in clinical scenarios for separate lung ventilation with good effect. VENTIL device, a flow divider, theoretically allows for independent, fully automated synchronous ventilation of 2 patients with use of only one respirator. In the shortage of respirators (ex. terrorist attack, natural disasters) device allows also to ventilate in classical system two patients using single respirator.
Ventil - independent lung ventilation system was constructed by engineers from Nalecz Institute of Biocybernetics and Biomedical Engineering of Polish Academy of Science. Ventil was tested in the clinical scenario - it's safety had been confirmed. Several years ago the working prototypes of the device, after approval of Ethical Committee, was tested in about 150 patients, who were ventilated with independent synchronous lung ventilation and had been found useful.
The idea of the study is to check the usefulness of the device (modern version) in ICU patients who can be ventilated with volume -controlled mode of ventilation as an attempt to use single device for ventilation of 2 patients. At this moment, according to several scientific societies, sharing mechanical ventilators should not be attempted because it cannot be done safely with current equipment. However, it is possible that using a designed flow divider will allow safe ventilation in patients without needs for complicated modes of ventilation. Then maybe it will be possible to release some ventilators and to use them in patients in severe condition, mainly in the era of extreme ventilator shortage. In the study Ventil will ventilate one patient and instead of the second, there will be an artificial lung. Tidal volumes, minute ventilation, PEEP set and final will be checked. Ppeak, Pmean, Pplat, Cdyn, airway resistance, EtCO2, Sat O2, HR, SAP, DAP will be monitored (every 2 hrs), as well as blood-gas analysis (every 8 hrs)
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Radoslaw Owczuk, prof
- Phone Number: +48583493270
- Email: r.owczuk@gumed.edu.pl
Study Contact Backup
- Name: Magdalena A Wujtewicz, dr
- Phone Number: +48583493270
- Email: magwuj@gumed.edu.pl
Study Locations
-
-
-
Gdansk, Poland, 80-214
- Recruiting
- Medical University of Gdansk
-
Contact:
- Magdalena A Wujtewicz
- Phone Number: +48583493357
- Email: magwuj@gumed.edu.pl
-
Contact:
- Radoslaw Owczuk
- Phone Number: 605408140
- Email: r.owczuk@gumed.edu.pl
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- ICU patients who require mechanical ventilation
Exclusion Criteria:
- Patients who require complex modes of ventilation will not be recruited
The sudy in an individual patient be discontinued if case of:
Respiratory Criteria:
- episodes of desaturation <90% (in pts without COPD) without reversibel reason
- need for FiO2 increase by 10%
- need for switch to other than CMV mode of ventillation
- need for neuromucular blockade or for deepen sedation because of assynchrony between patient and venilator
- cummulation of CO2>45 mm Hg (in pts without COPD) not responding to the increase of minute ventilation for 30 minutes
- Pplat >30 cmH2O
Circulatory criteria:
New haemodynamic disturbances that cannot be explaned by other reasons
- ↑ or ↓of BP by 20%
- ↑ or ↓of HR by 20%
- clinically important heart rhythm disturbances
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: mechanically ventilated patients
Adult ICU patients who are mechanically ventilated and who do not require complex modes of ventilation. A designated flow divider (Ventil) will be used to divide inspiratory gas flow from ventilator in two separate streams - one to the patient and the second to the artificial lung |
Checking ventilation parameters set and obtained and clinical parameters while ventilating the patient and an artificial lung simultaneously, using inspiratory flow divider.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of cases in which it was necessary to stop using Ventil and to step- back to ventilation without this flow divider
Time Frame: 48 hours
|
Ventil will be removed from the patient-ventilator circiuit in case of episodes of desaturation <90% (in pts without COPD) without reversibel reason; need for FiO2 increase by 10%; need for switch to other than CMV mode of ventillation need for neuromucular blockade or for deepen sedation because of assynchrony between patient and venilator cummulation of CO2>45 mm Hg (in pts without COPD) not responding to the increase of minute ventilation for 30 minutes; if Pplat >30 cmH2O; in case of new haemodynamic disturbances that cannot be explaned by other reasons; in case of increase or decrease of BP by 20%; increase or decrease of HR by 20%; in case of occurence of clinically important heart rhythm disturbances
|
48 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Radoslaw Owczuk, prof, Medical University of Gdansk
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Ventil-COVID-19
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Respiratory Insufficiency
-
NCT05418530RecruitingRespiratory Insufficiency in Children
-
NCT05229172CompletedRespiratory Insufficiency in Children
-
NCT05221710Not yet recruitingRespiratory Insufficiency Requiring Mechanical Ventilation
-
NCT04957472CompletedRespiratory Insufficiency in Children
-
NCT02972021UnknownPatients With Respiratory Insufficiency
-
NCT06143384Not yet recruitingRespiratory Insufficiency Requiring Mechanical Ventilation
-
NCT01458314CompletedChronic Respiratory Insufficiency
-
NCT04189991SuspendedCOPD | Chronic Respiratory Insufficiency
-
NCT06655805RecruitingRespiratory Insufficiency Requiring Mechanical Ventilation
-
NCT06675045Not yet recruiting
Clinical Trials on Ventil - a gas flow divider
-
NCT06013189RecruitingOptimal Sweep Gas Flow | Determination of Optimal Sweep Gas Flow for Different Phases of Cardiopulmonary Bypass
-
NCT01913977CompletedARDS (Acute Respiratory Distress Syndrome) | Respiratory Acidosis
-
NCT03739359Completed
-
NCT06952946CompletedNausea and Vomiting, Postoperative | Septoplasty/Septorhinoplasty
-
NCT03040297Completed
-
NCT02013869Terminated
-
NCT04815330Completed