Ultrasound to Predict the Prognosis of Rotator Cuff Tears
Ultrasound Shear Wave Elastography to Predict the Treatment Effect and Risk of Re-tear in Patients With Large-to-massive Rotator Cuff Tears
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Kaohsiung, Taiwan, 833
- Kaohsiung Chang Gung Memorial Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients who are diagnosed with rotator cuff tear by an orthopedist.
- The large-to-massive rotator cuff tears need to be confirmed by magnetic resonance imaging or ultrasound. The definitions of this diagnosis include a tear over 3 cm or any full-thickness of tears in more than two rotator cuff muscles.
- Being willing to cooperated with the arranged examinations before the operation.
Exclusion Criteria:
- Patients who are only diagnosed with partial-thickness rotator cuff muscle tears or small- to large- sized full-thickness tears.
- Patients who have acromioclavicular arthritis that needs distal clavicle resection.
- Patients who had serious glenohumeral arthritis, pseudoparalysis, or any other shoulder trauma history.
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change from baseline finding of sonoelastography
Time Frame: Baseline, 3 months, 6 months, 12 months
|
This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year.
The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle.
Linear transducer (4-9 MHz) would be used for the whole test.
The probe would be positioned along the longitudinal axis of the muscle belly.
Compressive sonoelastography technique is used for semiquantitative analysis.
In order to maintain the quality of images, quality factor needs to be over or equal to 60.
The quantitative analysis was performed by shear wave sonoelastography and the region of interest (ROI) would be divided into four quadrants.
The physicians will measure the shear wave velocity at the center point of each quadrant.
|
Baseline, 3 months, 6 months, 12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Passive range of motions
Time Frame: Baseline, 3 months, 6 months, 12 months
|
Passive range of motions of internal and external rotation, abduction, extension, and flexion, which are assessed by a goniometer.
|
Baseline, 3 months, 6 months, 12 months
|
|
Muscle strength
Time Frame: Baseline, 3 months, 6 months, 12 months
|
Muscle strength assessment include the following motions, which are internal and external rotation, abduction, extension, and flexion.
They are measured by a manual dynamometer
|
Baseline, 3 months, 6 months, 12 months
|
|
American Shoulder and Elbow Surgeons score (ASES score)
Time Frame: Baseline, 3 months, 6 months, 12 months
|
Shoulder function is evaluated using American Shoulder and Elbow Surgeons score, which includes one item for pain (VAS) and 10 items for shoulder function.
The ASES score ranges from 0 to 100, and the outcome is better when ASES score is higher.
|
Baseline, 3 months, 6 months, 12 months
|
|
Western Ontario Rotator Cuff Index (WORC index)
Time Frame: Baseline, 3 months, 6 months, 12 months
|
Shoulder function is evaluated using Western Ontario Rotator Cuff Index, which includes physical symptoms (10 items), sport/recreation/work function (4 items), lifestyle function (4 items), and emotional function (3 items).
The WORC index ranges from 0 to 2100 or can be converted to 0 to 100 scale, and the outcome is better when WORC index is lower.
|
Baseline, 3 months, 6 months, 12 months
|
|
WHOQOL-BREF (Taiwan version)
Time Frame: Baseline, 3 months, 6 months, 12 months
|
The WHOQOL-BREF (Taiwan version) instrument comprises 28 items, which measure the following broad domains: physical health, psychological health, social relationships, and environment.
The WHOQOL-BREF (Taiwan version) is a shorter version of the original instrument that may be more convenient for use in large research studies or clinical trials.
The total score WHOQOL-BREF (Taiwan version) can be transformed to a 0-100 scale, and the quality of life is better when the score is higher.
|
Baseline, 3 months, 6 months, 12 months
|
|
EQ-5D-3L
Time Frame: Baseline, 3 months, 6 months, 12 months
|
The EQ-5D-3L descriptive system comprises the following five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression.
Each dimension has 3 levels: no problems, some problems, and extreme problems.
The patient is asked to indicate his/her health state by ticking the box next to the most appropriate statement in each of the five dimensions.
This decision results into a 1-digit number that expresses the level selected for that dimension.
The digits for the five dimensions can be combined into a 5-digit number that describes the patient's health state.
|
Baseline, 3 months, 6 months, 12 months
|
|
MRI
Time Frame: Baseline, 6 months
|
MRI was performed on a 1.5T system (Signa Horizon LX, GE Healthcare) equipped with a standard shoulder surface coil.
The shoulder MRI protocol was identical for all patients and consisted of axial proton-density-weighted fast spinecho with fat suppression sequence, the sequences was performed above the level o f the acromioclavicular joint down to below the axillary pouch with the following parameters: Coronal oblique proton-density-weighted with and without fat suppression, with axis parallel to the supraspinatus tendon, and sagittal oblique proton-density--weighted with and without fat suppression, with axis perpendicular to the coronal oblique axis, the ast spin-echo sequences were performed with the following parameters: TR msec/TE msec, 2700-4800 /25-40, echo-train length, 6; matrix, 256 × 256; field of view, 180 mm; section thickness, 2.5 mm with 2-mm gap.
No IV or intraarticular gadolinium was administered.
|
Baseline, 6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Chair: Po-Cheng Chen, MD, Chang Gung Memorial Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- MOST 109-2314-B-182A-171
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.