Safety and Efficacy of the Sentinel Cerebral Protection Device in Atrial Fibrillation Ablation
A Pilot Randomized Study of the Use of The Sentinel Device for Cerebral Protection During Atrial Fibrillation Ablation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Joseph Abdel Messih
- Phone Number: 507-422-3967
- Email: mansour.joseph@mayo.edu
Study Locations
-
-
Minnesota
-
Rochester, Minnesota, United States, 55905
- Recruiting
- Mayo Clinic in Rochester
-
Contact:
- Grace Purkey
- Phone Number: (507) 255-0774
- Email: Purkey.Grace@mayo.edu
-
Principal Investigator:
- Malini Madhavan, MBBS
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Men / women over the age of 18 years undergoing radiofrequency, pulsed field or cryo-balloon ablation for AF in accordance with the current AHA/ACC/HRS guideline for management of patients with atrial fibrillation. This includes patients with symptomatic paroxysmal, persistent or long-standing persistent AF not responsive to or intolerant of a Class I or III anti-arrhythmic drug or patients with symptomatic paroxysmal or persistent AF prior to the initiation of a Class I or Class III antiarrhythmic drug). The decision to perform catheter ablation for AF will be made by the treating provider and the patient in accordance with the guidelines noted above. (January et al. J Am Coll Cardiol vol. 64, No. 21, 2014, page e1)
- Able to provide informed consent.
- Patients should have acceptable aortic arch anatomy and vessel diameters without significant stenosis as assessed using pre-procedure CT angiogram.
Exclusion Criteria:
Anatomy unsuitable for use of Sentinel device:
- Right extremity vasculature not suitable due to compromised arterial blood flow.
- Brachiocephalic, left carotid or aortic arch not suitable due to excessive tortuosity, significant ectasia, stenosis (>70%), dissection or aneurysm.
- Cerebrovascular accident or transient ischemic attack within six months
- Carotid disease requiring treatment within six weeks
- Unable or unwilling to provide informed consent.
- Pregnant women
- Known history of dementia.
- Known hypersensitivity to nickel-titanium.
- Presence of MRI non-compatible implanted devices including cardiac implantable electronic devices.
- The presence of left atrial thrombus. All patients routinely undergo transesophageal echocardiogram prior to ablation and / or intra-cardiac echocardiogram at the beginning of the ablation procedure to rule out the presence of left atrial thrombus.
- Patients with a reversible cause for AF such as hyperthyroidism.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Sentinel® Cerebral Protection System Group
Sentinel® Cerebral Protection System in patients undergoing AF catheter ablation
|
A percutaneously delivered dual-filter protection device, designed to capture and remove debris dislodged during transcatheter aortic valve replacement procedures.
Cerebral MRI will be performed without gadolinium contrast using a 3 Tesla scanner prior to and 1 to 7 days after catheter ablation
Other Names:
|
|
Active Comparator: Standard of Care Group
Standard of care (no cerebral protection device) in patients undergoing AF catheter ablation
|
Cerebral MRI will be performed without gadolinium contrast using a 3 Tesla scanner prior to and 1 to 7 days after catheter ablation
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incident of overt and covert CNS injury 7 days post AF ablation
Time Frame: 7 days post AF ablation
|
Incidence of overt and covert CNS injury confirmed using physical examination and / or brain imaging during or within 7 days of the AF ablation
|
7 days post AF ablation
|
|
Incident of overt and covert CNS injury 90 days post AF ablation
Time Frame: 90 days post AF ablation
|
Incidence of overt and covert CNS injury during or within 90 days of the AF ablation
|
90 days post AF ablation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
New cerebral infarcts
Time Frame: day 1 to 7 after atrial fibrillation ablation
|
Total number of new cerebral infarcts in the protected territories detected on brain MRI after ablation in the Sentinel device group vs control group
|
day 1 to 7 after atrial fibrillation ablation
|
|
Change in neurocognitive function score
Time Frame: Baseline, 90 days
|
Montreal cognitive assessment will administered at baseline and 90 days following ablation.
Change in cognitive function score will be compared between the groups.
The score ranges from 0 to 30 with higher score indicating better cognitive performance.
|
Baseline, 90 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Malini Madhavan, MBBS, Mayo Clinic
Publications and helpful links
Helpful Links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 19-002836
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.