Clinical Observation of Pulsed Dye Laser and Intense Pulsed Light in Treating Facial Telangiectasia
A Clinical Observation on the Efficacy and Safety of Pulsed Dye Laser and Intense Pulsed Light With Different Wavelength Bands in the Treatment of Facial Telangiectasia: a Retrospective, Self-controlled Trial
- Facial telangiectasia is one of the common skin vascular lesions characterized by dilated cutaneous vasculatures in the skin surface or mucous membranes. Lesions are generally sensitive to exposure of cold, heat and sun. Those distinct small dilated blood vessels are cosmetically disfiguring for patients which require an effective solution. The traditional management options for facial telangiectasia include cryotherapy, CO2 laser, topical agent, oral estrogens, electrosurgery, and radioactive treatment. However, inadequate outcomes and severe adversaries are the major concerns to patients and physicians.
Pulsed dye laser (PDL) is effective for vasodilatory diseases, especially for the superficial to middle layers of the dermis.
The intense pulsed light source is an alternative or supplement to the already existing laser devices that are part of the laser surgeon's repertoire. The broad wavelength spectrum and variable pulse duration allow greater penetration depths to be reached without damaging surrounding tissue and thus enhance the versatility of this system.
- This study aims to compare the clearance efficacy of facial telangiectasia using PDL (595nm) with IPL configured by various wavelength bands, including M22 vascular filter (530-650nm and 900-1200nm), M22 560 (560-1200nm), M22 590 (590-1200nm) .
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Shaanxi
-
Xi'an, Shaanxi, China, 710032
- Xijing Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Subjects must be clinically diagnosed with facial telangiectasia
- No other external treatment was performed before the injury was treated
Exclusion Criteria:
- subjects with a recent history of exposure to sunlight
- subjects allergic to topical anesthesia
- subjects with scar constitution
- subjects with skin malignant tumors or precancerous lesions
- subjects with diabetes, heart disease, epilepsy, connective tissue disease, etc
- subjects who Pregnant or breast feeding
- subjects with recent skin infections (such as viruses, bacteria, etc.)
- other methods are being used to treat subjects with similar diseases
- subject who have taken isotretinoin A in the past year
- subject with facial dermatitis
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Pulsed Dye Laser
PDL (Vbeam perfecta, 595 nm, Candela Corporation, Wayland, MA) was used with energy dosages of 9-11J/cm2, pulse durations of 10ms/20ms, and 7 or 10 mm handpieces with dynamic cooling device (DCD)
|
PDL (Vbeam perfecta, 595 nm, Candela Corporation, Wayland, MA) was used with energy dosages of 9-11J/cm2, pulse durations of 10ms/20ms, and 7 or 10 mm handpieces with dynamic cooling device (DCD). IPL device (M22, Lumenis Limited, Yokneam, Israel) with integration of sapphire ChillTip system for epidermal cooling were used in the study. Three wavelength bands were configured: 560-1200 nm, 590-1200 nm, and vascular wavelength bands of 530-650nm and 900-1200nm. All the treatment handpieces had a spot size of 15mm×35mm, fluence of 9-17J/cm², pulse duration of 4.0-6.0ms and pulse delay of 20-40ms, underwent the M22 advanced optimal pulse technology (AOPT) treatment.
Other Names:
|
|
Active Comparator: Intense Pulsed Light
Vascular wavelength bands of 530-650nm and 900-1200nm
|
PDL (Vbeam perfecta, 595 nm, Candela Corporation, Wayland, MA) was used with energy dosages of 9-11J/cm2, pulse durations of 10ms/20ms, and 7 or 10 mm handpieces with dynamic cooling device (DCD). IPL device (M22, Lumenis Limited, Yokneam, Israel) with integration of sapphire ChillTip system for epidermal cooling were used in the study. Three wavelength bands were configured: 560-1200 nm, 590-1200 nm, and vascular wavelength bands of 530-650nm and 900-1200nm. All the treatment handpieces had a spot size of 15mm×35mm, fluence of 9-17J/cm², pulse duration of 4.0-6.0ms and pulse delay of 20-40ms, underwent the M22 advanced optimal pulse technology (AOPT) treatment.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Severity index of facial telangiectasia
Time Frame: 6months
|
|
6months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Gang Wang, Prof, Dermatology Derpartment of Xijing Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- XijingH-PF-20192074-C-1
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Telangiectasia
-
NCT01327911CompletedIdiopathic Juxtafoveal Telangiectasia
-
NCT03845049Terminated
-
NCT01354093CompletedIdiopathic Juxtafoveal Telangiectasia
-
NCT06397131Active, not recruitingMacular Telangiectasia Type 2
-
NCT00211328CompletedIdiopathic Perifoveal Telangiectasia
-
NCT03319849CompletedA Study to Determine the Safety and Efficacy of NT-501 in Macular Telangiectasia Type 2 - Protocol BMacular Telangiectasia Type 2
-
NCT04907084Active, not recruitingMacular Telangiectasia Type 2
-
NCT00504400CompletedType 2 Idiopathic Macular Telangiectasia
-
NCT03071965CompletedMacTel (Macular Telangiectasia) Type 2
Clinical Trials on Pulsed dye laser
-
NCT00573729Completed
-
NCT00142441CompletedHypertrophic Scars | Keloids
-
NCT00206921UnknownPulsed Dye Laser and Intense Pulsed Light (IPL) for the Treatment of Telangiectasia and Skin RednessErythema | Telangiectasis
-
NCT00375141TerminatedPhotodamaged Skin
-
NCT03948997Completed
-
NCT03178188UnknownLupus Erythematosus, Discoid
-
NCT00506363Terminated