Pilot Feasibility Trial of the SafeLM Supraglottic Airway (SGA)
Pilot Feasibility Trial of the SafeLM Supraglottic Airway
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
- Device: SafeLM as a supraglottic airway device with video capability
- Device: SafeLM as a supraglottic airway device without video capability
- Device: SafeLM as a conduit for intubation using an endotracheal tube with video capability
- Device: SafeLM as a conduit for intubation using a bougie with video capability
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Lauren M Nakazawa, MD
- Phone Number: 713-500-6775
- Email: Lauren.M.Nakazawa@uth.tmc.edu
Study Contact Backup
- Name: Carlos Artime, MD
- Phone Number: 713-500-6171
- Email: Carlos.Artime@uth.tmc.edu
Study Locations
-
-
Texas
-
Houston, Texas, United States, 77030
- Recruiting
- The University of Texas Health Science Center at Houston
-
Contact:
- Lauren M Nakazawa, MD
- Phone Number: 713-500-6775
- Email: Lauren.M.Nakazawa@uth.tmc.edu
-
Contact:
- Carlos Artime, MD
- Phone Number: 713-500-6171
- Email: Carlos.Artime@uth.tmc.edu
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- elective surgery requiring general anesthesia and airway management using a supraglottic airway device or endotracheal intubation
Exclusion Criteria:
- pregnancy
- known or suspected difficult airway management
- history of oropharyngeal or upper airway surgery
- known or suspected airway or respiratory pathology, such as significant obstructive sleep apnea or chronic obstructive pulmonary disease (COPD)
- BMI greater than 40 kg/m2
- unable to undergo intubation via the oral route
- known or suspected full stomach or other risk factors for aspiration
- contraindication for the use of neuromuscular blocking agents
- history of significant gastroesophageal reflux disease (GERD)
- Vulnerable populations (cognitively impaired persons, prisoners)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: SafeLM as a supraglottic airway device with video capability
|
The device will be inserted using the video capability and used as a primary airway device for the duration of the surgical procedure.
Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.
The position of the device will be confirmed by observing the video image of the glottis on the monitor.
The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation.
Leak and cuff pressure will be assessed.
The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
|
|
Experimental: SafeLM as a supraglottic airway device without video capability
|
The device will be blindly inserted without using the video capability and used as a primary airway device for the duration of the surgical procedure.
Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.
The position of the device will be confirmed by observing the video image of the glottis on the monitor.
The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation.
Leak and cuff pressure will be assessed.
The video capability of the device will be used to assess the accuracy of placement after the fact.
The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.
|
|
Experimental: SafeLM as a conduit for intubation using an endotracheal tube with video capability
|
The device will be inserted, and an endotracheal tube will be advanced through the device under direct visualization using the video capability of the device.
Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.
The endotracheal tube will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.
The endotracheal tube will be advanced into the trachea, and the position will be confirmed by end-tidal carbon dioxide (EtCO2) detection and chest auscultation.
The cuff of the endotracheal tube will be inflated, and mechanical ventilation will be resumed.
The SafeLM device will be removed, and the position of the endotracheal tube will be confirmed once again.
|
|
Experimental: SafeLM as a conduit for intubation using a bougie with video capability
|
The device will be inserted.
Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.The position of the device will be confirmed by observing the video image of the glottis on the monitor.
The video camera on the SafeLM will be turned on to visualize the vocal cords.A standard airway bougie will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.The SafeLM device will be removed, and an appropriately sized endotracheal tube will be advanced into the trachea.
If a bougie is not able to be inserted into the tracheal under direct visualization, direct insertion of an endotracheal tube into the trachea will be attempted, followed by flexible scope intubation.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intubation success rate
Time Frame: at the time of intubation
|
This is assessed by the ability of the SafeLM to achieve adequate oxygenation and ventilation via the respective procedure once the airway device is in place.
|
at the time of intubation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of insertion attempts required to achieve effective oxygenation and ventilation
Time Frame: at the time of intubation
|
at the time of intubation
|
|
|
Time to insertion
Time Frame: at the time of intubation
|
This is measured by the time from opening the mouth to the time of end tidal CO2 on capnography
|
at the time of intubation
|
|
Subjective ease of insertion of the airway device
Time Frame: at the time of intubation
|
at the time of intubation
|
|
|
Safety of the SafeLM as an SGA
Time Frame: at the time of intubation
|
This will be assessed by the number of adverse events such as airway obstruction, aspiration, and hypoxia.
|
at the time of intubation
|
|
Safety of the SafeLM as a conduit for intubation
Time Frame: at the time of intubation
|
This will be assessed by the number of adverse events such as esophageal intubation, bronchial intubation, and hypoxia during the intubation process.
|
at the time of intubation
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Lauren M Nakazawa, MD, The University of Texas Health Science Center, Houston
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- HSC-MS-23-0537
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.