Comparison Between Conventional and CAD/CAM Complete Dentures Designed Based on Neutral Zone Concept
Comparison of Electromyographic Muscle Activity and Occlusal Accuracy Between Conventional and CAD/CAM Complete Dentures Designed Based on Neutral Zone Concept (Randomized Controlled Clinical Trial)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Omnia MS Refai, PHD
- Phone Number: +02 +201202420046
- Email: omnia_refaie@dent.asu.edu.eg
Study Contact Backup
- Name: Sara IS Mohamed, PHD
- Phone Number: +02 01285446141
- Email: Saraibrahim@dent.asu.edu.eg
Study Locations
-
-
-
Cairo, Egypt, 11566
- Faculty of Dentistry, Ain Shams University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients who have been completely edentulous in both jaws (maxilla and mandible) for a long period.
- Patients with a resorbed mandibular ridge.
- Patients with a Class I maxillo-mandibular relationship
- Patients with adequate inter-arch space.
- Patients with good neuromuscular control.
- Patients without any tempo-mandibular disorder.
Exclusion Criteria:
- Patients with any oral diseases that may affect complete denture construction
- Patients with bad oral hygiene.
- Patients with neuromuscular disorders.
- Patients with a history of parafunctional habits.
- Hysterical patients.
- Patients will undergo or have previously received chemotherapy or radiotherapy.
- Drug-addicted patients.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: CAD/CAM Milled Methacrylate Complete Removable Dentures based on neutral zone concept.
The patient will be provided with a complete removable denture designed according to the neutral-concept to restore his missing teeth, which will be manufactured by CAD/CAM milling of monolithic methacrylate blanks.
|
The patients will receive complete removable dentures designed based on the neutral-zone concept and digitally manufactured using a milling machineز
|
|
Experimental: Heat Cured Conventional Complete Removable Dentures based on neutral zone concept
The patient will be provided by a complete removable denture designed based on the neutral zone concept to restore his missing teeth which will be manufactured by heat curing of Polymethyl methacrylate.
|
The patients will receive complete removable dentures designed based on neutral zone concept and manufactured by heat cured conventional technique of polymethylmethacrylate
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of the electromyography muscle activity (EMG) of the masseter and temporalis muscles.
Time Frame: one month
|
The electromyography activity of the Masseter and Temporalis muscles will be evaluated during clenching, chewing of soft food, and chewing of hard food, at the time of denture insertion (baseline) and one month after baseline.The measuring unit is mv.
|
one month
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of occlusal force equilibration using t-scan device
Time Frame: two weeks
|
The percentage of occlusal force distribution will be evaluated for both dentures using the T-Scan computerized occlusal analysis system, at the time of denture insertion (baseline) and following baseline by two weeks after.
|
two weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Omnia MS Refai, PHD, Faculty Of Dentistry Ain Shams University
- Principal Investigator: Omar A El-Sadat, PHD, Faculty Of Dentistry Ain Shams University
- Principal Investigator: Sara IS Mohamed, PHD, Faculty of Dentistry , Ain Shams Univeristy
Publications and helpful links
General Publications
- Ohkubo C, Shimpo H, Tokue A, Park EJ, Kim TH. Complete denture fabrication using piezography and CAD-CAM: A clinical report. J Prosthet Dent. 2018 Mar;119(3):334-338. doi: 10.1016/j.prosdent.2017.04.013. Epub 2017 Jul 15.
- Cagna DR, Massad JJ, Schiesser FJ. The neutral zone revisited: from historical concepts to modern application. J Prosthet Dent. 2009 Jun;101(6):405-12. doi: 10.1016/S0022-3913(09)60087-1.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- FDASU-ReclR012317
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.