High Altitude (HA) Residents With Pulmonary Vascular Diseases (PVD), 6 Minute Walk Distance (6MWD) Assessed at 2840m (HA) With and Without Supplemental Oxygen Therapy (SOT)
Effect of Supplemental Oxygen Therapy (SOT) in Patients With Pulmonary Vascular Diseases (PVD) Defined as Pulmonary Arterial Hypertension or Chronic Thromboembolic Pulmonary Hypertension (PH) Who Permanently Live >2500m on 6-minute Walk Distance (6MWD)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Silvia Ulrich, Prof. Dr.
- Phone Number: +41442552220
- Email: silvia.ulrich@usz.ch
Study Contact Backup
- Name: Mona Lichtblau, Dr.
- Phone Number: +41442552220
- Email: mona.lichtblau@usz.ch
Study Locations
-
-
-
Zürich, Switzerland, 8091
- University Hospital Zurich
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
IInclusion Criteria:
- Adult patients 18-80 years old of both genders,
- Residence > 2500m of altitude
- diagnosed with precapillary PH (mean pulmonary artery pressure (mPAP) >20 mmHg, pulmonary artery wedge pressure (PAWP) ≤15 mmHg and pulmonary vascular resistance (PVR) ≥2 wood units (WU) by right heart catheterization) with PH being classified as PAH or CTEPH according to guidelines
- Patients stable on therapy
- New York Heart Association (NYHA) functional class I-III
- Provided written informed consent to participate in the study.
Exclusion Criteria:
- Age <18 years or >80 years
- unstable condition
- Patients who cannot follow the study investigations, patient permanently living < 2500m.
- Patients with moderate to severe concomitant lung disease (FEV1<70% or forced vital capacity <70%), severe parenchymal lung disease, severe smokers (>20 cigarettes/day)
- Severely hypoxemic patients at Quito permanently have persistent oxygen saturation by pulseoximetry (SpO2) <80% on ambient air.
- Patients with chronic mountain sickness (Hemoglobin > 19 g/dl in women, >21 g/dl in men)
- Patient with a non-corrected ventricular septum defect
- Relevant concomitant other disease of the heart, kidney, liver, blood (anemia hemoglobin<11 g/dl)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: SOT via nasal canula
Supplemental oxygen therapy (SOT) at 3l/min will be provided via a nasal cannula from a small oxygen bottle carried on the back according to standard care
|
6-minute walk distance (6MWD) test will be performed according to clinical standards additionally with supplemental oxygen therapy (3l/min, nasal)
|
|
Active Comparator: Ambient air
Patient will perform tests on ambient air at 2840 m
|
6-minute walk distance (6MWD) test will be performed according to clinical standards
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
6-minute walk distance (6MWD) with supplemental oxygen therapy (SOT) vs. ambient air at 2840m
Time Frame: after 6 minute
|
Change in 6MWD in meter between SOT 3l/min via nasal cannula vs. ambient air at 2840m
|
after 6 minute
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
SpO2 at rest and peak 6MWD with SOT vs. ambient air at 2840m
Time Frame: 6 minutes
|
Change of the arterial oxygen saturation by pulseoximetry (SpO2) at rest and at peak 6MWD with SOT 3l /min vs. ambient air at 2840 m
|
6 minutes
|
|
Heart rate at rest and peak 6MWD with SOT vs. ambient air at 2840m
Time Frame: 6 minutes
|
Change of heart rate (bpm) at rest and at peak 6MWD with SOT 3l /min vs. ambient air at 2840 m
|
6 minutes
|
|
Blood pressure at rest and peak 6MWD with SOT vs. ambient air at 2840m
Time Frame: 6 minutes
|
Change of Blood pressure (mmHg) at rest and at peak 6MWD with SOT 3l /min vs. ambient air at 2840 m
|
6 minutes
|
|
Borg dyspnea scale at rest and peak 6MWD with SOT vs. ambient air at 2840m
Time Frame: 6 minutes
|
Change of Borg dyspnea scale at rest and at peak 6MWD with SOT 3l /min vs. ambient air at 2840 m
|
6 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Silvia Ulrich, Prof. Dr., University Hospital Zurich, Departement of Pulmonology
- Principal Investigator: Rodrigo Hoyos, Dr., Carlos Adrade Marin Hospital of Quito, Equador
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- PVD_HA_SOT_6MWD
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.