Outcomes of High vs Physiological Intraocular Pressure During Cataract Surgery Using ACTIVE SENTRY (ACTIVESENTRY)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Samir Jabbour, MD,CM,FRCSC
- Phone Number: 11550 514-890-8000
- Email: Samir.Jabbour.med@ssss.gouv.qc.ca
Study Contact Backup
- Name: Marie-Catherine Tessier, M.Sc.
- Phone Number: 11550 514 890-8000
- Email: marie-catherine.tessier.chum@ssss.gouv.qc.ca
Study Locations
-
-
Quebec
-
Montreal, Quebec, Canada
- Centre Hospitalier de l'Université de Montréal
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- No prior ocular surgery including corneal refractive surgery
- Bilateral visually significant cataract, similar in density (LOCS III grade 2+), undergoing uncomplicated cataract surgery
- Equal dilated pupil size ≥6mm, no use of pupil expansion devices
- Axial length 21-26mm, refractive error between -8.00D to +6.00D and cylinder ≤ 4.50D, normal K values <48.00D
- Normal CCT range 540µm ± 50
Exclusion Criteria:
- History of corneal disease or dystrophies
- Media opacification for reasons other than cataract
- Compromised zonular integrity or stability.
- Retinal and retinal vascular pathologies, age-related macular degeneration
- Glaucoma
- Patients with uncontrolled systematic diseases, including hypertension, diabetes, systemic cardiovascular diseases, and hematological diseases.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Cataract surgery with Active Sentry
Cataract surgery with low IOP values (32mmHg)
|
Surgical instrument that detects changes in intraocular pressure and allows rapid feedback to stabilize pressure during cataract surgery.
|
|
Active Comparator: High IOP
Cataract surgery with high IOP (60mmHg) which is the average pressure at which cataract surgery is being performed currently
|
Cataract surgery performed with high intraocular pressures
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Central corneal thickness at 1 day postoperatively
Time Frame: 1 day postoperatively
|
Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively.
CCT will be measured using a pachymetry (Normal CCT range 540µm ± 50).
|
1 day postoperatively
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Volume of balanced salt solution used during surgery
Time Frame: During surgery
|
Volume of balanced salt solution as measured by the Active Sentry Centurion machine
|
During surgery
|
|
Total ultrasound time and total aspiration time
Time Frame: During surgery
|
Total ultrasound time and total aspiration time as measured by the Active Sentry Centurion machine
|
During surgery
|
|
Endothelial cell loss (inner surface of the cornea)
Time Frame: At month 1 and month 3 postoperatively.
|
Endothelial cell count measured by specular microscopy
|
At month 1 and month 3 postoperatively.
|
|
Central corneal thickness
Time Frame: 1 week, 1 month and 3 months postoperatively
|
Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively.
CCT will be measured using a pachymetry (Normal CCT range 540µm ± 50).
|
1 week, 1 month and 3 months postoperatively
|
|
Corneal clarity
Time Frame: Day 1, week 1, month 1 and month 3 postoperatively
|
Measured uring the Pentacam corneal densitometry
|
Day 1, week 1, month 1 and month 3 postoperatively
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Visual acuity
Time Frame: Day 1, week 1, month 1, and month 3 postoperatively
|
Evaluated using a Snellen chart
|
Day 1, week 1, month 1, and month 3 postoperatively
|
|
Low contrast evaluation
Time Frame: Day 1, week 1, month 1, and month 3 postoperatively
|
Evaluated using the CSV-1000 Contrast Sensitivity chart with glare
|
Day 1, week 1, month 1, and month 3 postoperatively
|
|
Intraocular pressure
Time Frame: Day 1, week 1, month 1, and month 3 postoperatively
|
Measured using the Goldmann Applanation Tonometer
|
Day 1, week 1, month 1, and month 3 postoperatively
|
|
Cystoid macular edema
Time Frame: 1 month postoperatively
|
Evaluated using the Macular Optical Coherence Tomography (OCT)
|
1 month postoperatively
|
|
Rate of reverse pupillary block
Time Frame: 1 day, 1 week, 1 month and 3 months postoperatively
|
Evaluated using slit lamp examination
|
1 day, 1 week, 1 month and 3 months postoperatively
|
|
Posterior capsular tear
Time Frame: During surgery
|
Complication during cataract surgery
|
During surgery
|
|
Posterior capsular rupture
Time Frame: During surgery
|
Complication during cataract surgery
|
During surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Samir Jabbour, MD,CM,FRCSC, Centre hospitalier de l'Université de Montréal (CHUM)
Publications and helpful links
General Publications
- Zhao Y, Li X, Tao A, Wang J, Lu F. Intraocular pressure and calculated diastolic ocular perfusion pressure during three simulated steps of phacoemulsification in vivo. Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2927-31. doi: 10.1167/iovs.08-2996. Epub 2009 Jan 24.
- Vasavada AR, Praveen MR, Vasavada VA, Vasavada VA, Raj SM, Asnani PK, Garg VS. Impact of high and low aspiration parameters on postoperative outcomes of phacoemulsification: randomized clinical trial. J Cataract Refract Surg. 2010 Apr;36(4):588-93. doi: 10.1016/j.jcrs.2009.11.009.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2025-11959
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.