- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT02061592
Evaluation of Etafilcon A Daily Disposable Lenses
June 18, 2018 updated by: Johnson & Johnson Vision Care, Inc.
Clinical Evaluation of Two Etafilcon A Daily Disposable Lenses
To evaluate the clinical performance of daily disposable etafilcon A lenses.
Study Overview
Study Type
Interventional
Enrollment (Actual)
136
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Florida
-
Jacksonville, Florida, United States
-
-
Hawaii
-
'Aiea, Hawaii, United States
-
Honolulu, Hawaii, United States
-
Kahului, Hawaii, United States
-
Waipahu, Hawaii, United States
-
-
New York
-
New York, New York, United States
-
-
Texas
-
Houston, Texas, United States
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years to 70 years (ADULT, OLDER_ADULT)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
Inclusion Criteria:
- The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form.
- The subject must appear able and willing to adhere to the instructions set forth in this clinical protocol.
- The subject must be at least 18 and not more than 70 years of age.
- The subject's refractive cylinder must be < 1.00 Diopters (D) in each eye.
- The subject must have best corrected visual acuity of 20/25 or better in each eye.
- The subject's required spherical contact lens prescription must be in the range of -0.50 to -7.50 D in each eye.
- The subject must be a habitual and adapted wearer of daily disposable contact lenses in both eyes.
- The subject must self-report their race as Asian
- The subject must have normal eyes (i.e., no ocular medications or infections of any type).
- The subject must demonstrate adequate mobility and 20/30 vision oculus dexter (OD) and oculus sinister (OS) with the study contact lenses.
Exclusion Criteria:
- Currently pregnant or lactating (subjects who become pregnant during the study will be discontinued).
- Any ocular or systemic allergies or diseases that may interfere with contact lens wear.
- Any systemic disease, autoimmune disease, or use of medication that may interfere with contact lens wear.
- Entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia.
- Any previous, or planned, ocular or interocular surgery (e.g., radial keratotomy, photorefractive keratectomy (PRK), laser in-situ keratomileusis (LASIK), etc.).
- Any grade 3 or greater slit lamp findings (e.g., edema, corneal neovascularization, corneal staining, tarsal abnormalities, conjunctival injection) on the FDA classification scale, any previous history or signs of a contact lens-related corneal inflammatory event (e.g., past peripheral ulcer or round peripheral scar), or any other ocular abnormality that may contraindicate contact lens wear.
- Any ocular infection.
- Any corneal distortion resulting from previous hard or rigid gas permeable contact lens wear.
- Monovision or multi-focal contact lens correction.
- Participation in any contact lens or lens care product clinical trial within 14 days prior to study enrollment.
- History of binocular vision abnormality or strabismus.
- Any infectious disease (e.g., hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g., HIV, by self report).
- Suspicion of or recent history of alcohol or substance abuse.
- History of serious mental illness.
- History of seizures.
- Employee of investigational clinic (e.g., Investigator, Coordinator, Technician)
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: DOUBLE
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Etafilcon A Control Lens
etafilcon A
|
|
|
EXPERIMENTAL: Etafilcon A Test Lens
etafilcon A
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Overall Comfort
Time Frame: 1-week follow-up
|
Subjective assessment of comfort was performed using the Contact Lens User Experience TM (CLUE) questionnaire.
CLUE was a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft, disposable contact lenses (comfort, vision, handling, and packaging) in a contact lens- wearing population in the US, ages 18-65.
Scores follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicated a more favorable/positive response with a range of 0 to 120.
|
1-week follow-up
|
|
Overall Vision
Time Frame: 1- week Follow-up
|
Subjective assessment of vision was performed using the Contact Lens User Experience TM (CLUE) questionnaire.
CLUE was a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft, disposable contact lenses (comfort, vision, handling, and packaging) in a contact lens-wearing population in the US, ages 18-65.
Scores follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicated a more favorable/positive response with a range of 0 to 120.
|
1- week Follow-up
|
|
Monocular Logarithm of the Minimum Angle of Resolution (logMAR) Visual Acuity - Standard High Contrast Dim
Time Frame: 1-week follow-up
|
LogMar visual acuity within each eye was measured using Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity charts.
A LogMar acuity value of 0 indicates that a subject has 20/20 vision.Positive LogMar acuity values indicate worsened vision while negative LogMar acuity values would indicated improved vision.
|
1-week follow-up
|
|
Monocular logMar Visual Acuity - Standard Low Contrast Bright
Time Frame: 1- week Follow-up
|
LogMar visual acuity within each eye was measured using Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity charts.
A LogMar acuity value of 0 indicates that a subject has 20/20 vision.
Positive LogMar acuity values indicate worsened vision while negative LogMar acuity values would indicated improved vision.
|
1- week Follow-up
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start
January 1, 2014
Primary Completion (ACTUAL)
March 1, 2014
Study Completion (ACTUAL)
March 1, 2014
Study Registration Dates
First Submitted
February 7, 2014
First Submitted That Met QC Criteria
February 12, 2014
First Posted (ESTIMATE)
February 13, 2014
Study Record Updates
Last Update Posted (ACTUAL)
June 19, 2018
Last Update Submitted That Met QC Criteria
June 18, 2018
Last Verified
August 1, 2015
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- CR-5553
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Myopia
-
Tianjin Medical University Eye HospitalNot yet recruitingProgressive Myopia | Pediatric Myopia | Orthokeratology-related Myopia Progression
-
Shanghai General Hospital, Shanghai Jiao Tong University...Not yet recruitingMyopia | Myopia, ProgressiveChina
-
SightGlass Vision, Inc.Recruiting
-
University of FaisalabadCompletedRefractive Errors | Myopia | Progressive MyopiaPakistan
-
He Eye HospitalNot yet recruiting
-
Zhongshan Ophthalmic Center, Sun Yat-sen UniversityActive, not recruiting
-
University Eye Hospital, FreiburgActive, not recruiting
-
University of BradfordUniversity of Huddersfield; CooperVision International Limited (CVIL)Enrolling by invitationMyopia, ProgressiveUnited Kingdom
-
Shanghai 10th People's HospitalCompletedMyopia | Myopia, ProgressiveChina
-
Tianjin Eye HospitalActive, not recruiting
Clinical Trials on etafilcon A
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited Kingdom
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited States
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.Visioncare Research Ltd.Completed
-
Johnson & Johnson Vision Care, Inc.Visioncare Research Ltd.; Johnson & Johnson K.K. Medical CompanyCompleted
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.Eurolens ResearchCompleted