Clinical Evaluation of Investigational Contact Lenses
June 14, 2017 updated by: Johnson & Johnson Vision Care, Inc.
Single-visit, unmasked, non-dispensing study where subjects will wear three different lenses bilaterally in one visit, each lens being worn for approximately 30-60 minutes.
Subjects will complete a questionnaire for each study lens.
Study Overview
Status
Completed
Conditions
Intervention / Treatment
Study Type
Interventional
Enrollment (Actual)
116
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Kowloon
-
Hong Hom, Kowloon, Hong Kong
- Hong Kong Polytechnic University
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
18 years to 55 years (ADULT)
Accepts Healthy Volunteers
Yes
Genders Eligible for Study
All
Description
Inclusion Criteria:
- Subjects must be at least 18 years of age and no more than 55 years of age (inclusive).
- The subject's vertex corrected best spherical distance refraction must be in the range of -1.00 to -6.00 Diopters (D) in each eye.
- The subject's vertex corrected cylindrical component of distance refraction must be less than or equal to -1.50 Diopters of Cylinder (DC) in each eye.
- Subjects must have best corrected visual acuity of 20/25 (Snellen or equivalent) or better in each eye.
- Subjects must self-report as being Asian race.
- Subjects must self-report as having brown or black eyes.
- Subjects must be habitual lens wearer (clear or limbal ring cosmetic) . Habitual is defined as at least one (1) month of Contact Lens wear where the lenses were worn for a minimum of six (6) hours per day and a minimum of three (3) days per week.
- Subjects between 18 to 39 years old must be habitual limbal ring cosmetic lens wearers or must have tried limbal ring cosmetic lens within the past two years.
- Subjects must be cosmetic contact lens concept acceptors as determined by screening questionnaire.
- Subjects must possess a functional / usable pair of spectacles and bring them to the visit (only if applicable - to the investigator's discretion).
- Subjects must read, understand, and sign the Statement of Informed Consent.
- Subjects must appear able and willing to adhere to the instructions set forth in the clinical protocol.
- Subjects must be willing to have their eyes video recorded and photographed.
Exclusion Criteria:
- Working for any advertising agency, any company involved in public relations or marketing, market research; or any company that makes or sells contact lenses or glasses.
- Participated in any paid market research within the past 3 months.
- Pregnant or breast feeding a baby.
- Subjects with diabetes.
- Any ocular or systemic allergies or disease which might interfere with contact lens wear.
- Any systemic disease, or autoimmune disease, which might interfere with contact lens wear, at investigator's discretion.
- Using medications during and immediately preceding the study period that may interfere with current contact lens wear as determined by the investigators
- Any infectious diseases (e.g. hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g. HIV), by self-report.
- Any grade 3 or greater Biomicroscopy findings (this includes, corneal edema, corneal staining, corneal vascularization, conjunctival injection, tarsal abnormalities, bulbar injection) on the FDA classification scale.
- Any active ocular abnormalities/conditions that might interfere with contact lens wear (this includes, but not limited to, chalazia, recurrent styles, pterygium, infection etc.).
- Any corneal distortion, scar, or opacity affecting vision as noted by subjects or investigators during examination.
- History of any corneal surgery (e.g. radial keratotomy (RK), photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK)); confirmed with topography if necessary at the investigator's discretion.
- Habitual wearers of rigid gas permeable or orthokeratology lens within the past 3 months.
- Current habitual contact lens modality for extended wear or conventional wear (contact lenses with a replacement schedule of 3 months to >1 year).
- Participation in any pharmaceutical, medical device, or contact lens related clinical research trial within 14 days prior to study enrollment. This excludes studies that do not require product treatment/intervention.
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: NONE
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
ACTIVE_COMPARATOR: Group Sequence A, B, C
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
|
ACTIVE_COMPARATOR: Group Sequence B, C, A
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
|
ACTIVE_COMPARATOR: Group Sequence C, A, B
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
|
ACTIVE_COMPARATOR: Group Sequence C, B, A
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
|
ACTIVE_COMPARATOR: Group Sequence A, C, B
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
|
ACTIVE_COMPARATOR: Group Sequence B, A, C
Subjects will wear Test 1, Test 2, and Control contact lenses in order according to the randomization sequence assigned for approximately 30-60 minutes each, with a 5-minute wash-out period between lenses.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
CLUE Handling
Time Frame: 30 Minutes Post Insertion
|
CLUE Handling is assessed using the Contact Lens User Experience (CLUE™) Questionnaire.
CLUE™ is a validated patient-reported outcomes questionnaire to assess patient experience attributes of soft, disposable contact lenses (comfort, vision, handling, and packaging) in a contact lens-wearing population in the US, ages 18-65.
Scores follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable / positive response.
97% of the scores fall within 0 and 120 (mean +/- 3XSD).
|
30 Minutes Post Insertion
|
Visual Performance (LogMar)
Time Frame: 30 Minutes Post Insertion
|
Distance time controlled Visual Performance (LogMAR) was assessed for each subject eye under bright-illumination high-contrast lighting conditions at 4m using an ETDRS chart.
The average visual performance (LogMAR) was reported for each study lens.
|
30 Minutes Post Insertion
|
Percentage of Eyes With Acceptable Mechanical Lens Fit
Time Frame: 30 Minutes Post Insertion
|
Mechanical lens fit will be assessed for each subject and eye using a slit lamp.
Lens fit is a binary response and 'Yes' = Acceptable Fit and 'No' = Unacceptable Fit.
Lens fit is assessed using Lens centration, limbal exposure, primary gaze movement, up-gaze movement, edge lift, lens tightness.
Unacceptable fit will be declared if there is any of the following present: limbal exposure, edge lift, excessive movement in primary or up-gaze or insufficient movement in primary gaze and up-gaze.
The Percentage of subject eyes with acceptable lens fit will be reported.
|
30 Minutes Post Insertion
|
Percentage of Eyes With Acceptable Cosmetic Lens Fit
Time Frame: 30 Minutes Post Insertion
|
Cosmetic lens fitting is assessed for each subject eye in the primary gaze position without a slit lamp.
Cosmetic lens fit is a binary response and is reported as acceptable or unacceptable.
The Percentage of subject eyes with acceptable cosmetic lens fitting is reported.
|
30 Minutes Post Insertion
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (ACTUAL)
April 24, 2016
Primary Completion (ACTUAL)
May 22, 2016
Study Completion (ACTUAL)
May 22, 2016
Study Registration Dates
First Submitted
May 11, 2016
First Submitted That Met QC Criteria
June 14, 2016
First Posted (ESTIMATE)
June 15, 2016
Study Record Updates
Last Update Posted (ACTUAL)
July 11, 2017
Last Update Submitted That Met QC Criteria
June 14, 2017
Last Verified
June 1, 2017
More Information
Terms related to this study
Other Study ID Numbers
- CR-5759
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
Yes
product manufactured in and exported from the U.S.
Yes
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Visual Acuity
-
Alcon ResearchQueensland University of TechnologyRecruiting
-
Johnson & Johnson Vision Care, Inc.Completed
-
Alcon ResearchCompletedVisual AcuityUnited States
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited States
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited States
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited States
-
Johnson & Johnson Vision Care, Inc.Completed
Clinical Trials on Etafilcon A Design 1 (Test 1)
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited Kingdom
-
Johnson & Johnson Vision Care, Inc.CompletedCorneal SwellingCanada
-
Coopervision, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.CompletedVisual AcuityUnited States, Hong Kong
-
Coopervision, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.Visioncare Research Ltd.Completed
-
Johnson & Johnson Vision Care, Inc.Completed
-
Johnson & Johnson Vision Care, Inc.University of ManchesterCompleted
-
Coopervision, Inc.Completed