Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI

Clinical Evaluation of the Safety and Performance of the MicroPort's Transcatheter Aortic Valve and Delivery System for Treatment of Severe Aortic Stenosis

The objective of this study is to evaluate the safety and effectiveness of the MicroPort's Valve and delivery system for transcatheter aortic valve implantation (TAVI) in severe aortic stenosis who are considered unsuitable for Surgical Valve Replacement.

Study Overview

Detailed Description

  1. Evaluate the performance, safety and clinical benefit of MicroPort's aortic valve prosthesis and delivery system in intervention by peripheral artery.
  2. The study Continuous observe 12 months of safety and efficacy. Approximately 89 patients are recruited in the study with native aortic valve stenosis which are considered unsuitable for Surgical Valve Replacement.

Study Type

Interventional

Enrollment (Anticipated)

89

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Shanghai, China, 200032
        • Shanghai Zhongshan Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • 18 years or older, male or non pregnant women;
  • Senile degenerative aortic valve stenosis with echocardiography derived criteria: mean gradient ≥ 40 mmHg, or jet velocity ≥ 4.0 m/s, or an aortic valve area (AVA) of < 1.0 cm2 (or AVA index < 0.6 cm2/m2)
  • Symptomatic due to aortic valve stenosis as demonstrated by NYHA (New York Heart Association) Functional Class ≥ II
  • Expectation of life>12 months
  • Calcific aortic stenosis, which is suitable for transcatheter aortic valve implantation anatomically
  • is evaluated by at least two cardiovascular physicians, and they agreed that medical factors precluding operation suitable for surgery (the probability of death or serious, irreversible morbidity exceeded 50%)
  • The subject agreed to comply follow-up evaluation

Exclusion Criteria:

  • Evidence of an acute myocardial infarction ≤ 1 month before the intended treatment
  • aortic valve is a congenital unicuspid valve, or is non-calcified.
  • Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days
  • Implanted any heart valve prosthesis, prosthetic valve ring, severe(>3+)mitral valve insufficiency
  • Blood dyscrasia such as leukopenia (WBC < 3×109/L), acute anemia (Hgb < 90 g/L), thrombocytopenia (PLT < 50×109/L), bleeding diathesis, or history of coagulopathy.
  • Untreated clinically significant coronary artery disease requiring revascularization
  • Hemodynamic instability requiring mechanical cardiac assist or mechanical hemodynamic support devices
  • Need for emergency surgery for any reason
  • Hypertrophic cardiomyopathy with or without obstruction
  • Severe ventricular dysfunction with LVEF (Left ventricular ejection fraction) < 20%
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  • Active peptic ulcer or upper gastro-intestinal bleeding within the prior 3 months
  • A known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated.
  • Native aortic annulus size < 17 mm or> 29 mm.
  • Patient refuses aortic valve replacement surgery.
  • Cerebrovascular Accident (CVA) within 6 months, including TIA (transient ischemic attack).
  • Renal insufficiency (creatinine > 3.0 mg/dL) and/or end stage renal disease requiring chronic dialysis.
  • Life expectancy < 12 months
  • Significant abdominal or thoracic aorta disease, including aneurysm, marked tortuosity (hyperacute bend), aortic arch atheroma, narrowing of the abdominal aorta (especially with calcification and surface irregularities), or severe "unfolding" and tortuosity of the thoracic aorta
  • Iliofemoral vessel characteristics that would preclude safe placement of 16F to 19F introducer sheath such as severe obstructive calcification, severe tortuosity
  • Active bacterial endocarditis or other active infections.
  • Bulky calcified aortic valve leaflets in close proximity to coronary ostia
  • severe incapacitating dementia.
  • Currently participating in an investigational drug or another device study that has not reached its primary endpoint.
  • Researchers identify that the patients with poor compliance who cannot be completed in accordance.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: MicroPort's Transcatheter Aortic Valve and Delivery System
single arm with intervention that percutaneous implantation of the MicroPort's Transcatheter Aortic Valve and Delivery System

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
All cause mortality or major stroke at 12 months.
Time Frame: 12 months
12 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
MACCE(major adverse cardiovascular and cerebrovascular events)
Time Frame: 30 days, 3, 6 and 12 months

MACCE is defined as a composite of:

  • Myocardial infarction (MI)
  • Hemorrhage
  • renal failure
  • vascular complications
  • block
  • ventricular arrhythmias
30 days, 3, 6 and 12 months
Device success
Time Frame: 7 days post-operation

Device success is defined as

  • The device successfully enter the vascular approach, transport and release
  • The valve is placed in the correct anatomical position
  • The valve achieve the expected effect (mean aortic pressure < 20mmHg or peak velocity < 3m/s, with no severe aortic regurgitation or paravalvular leakage)
7 days post-operation
Valve performance
Time Frame: 30 days, 3, 6 and 12 months

Valve performance means:

  • Transvalvular mean gradient
  • Effective orifice area
  • Degree of aortic valve regurgitation (transvalvular and paravalvular)
30 days, 3, 6 and 12 months
The improvement of heart function
Time Frame: 30 days, 3, 6 and 12 months
30 days, 3, 6 and 12 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: JunBo Ge, Medical Doctor, Professor, Shanghai Zhongshan Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

September 1, 2014

Primary Completion (ANTICIPATED)

September 1, 2016

Study Completion (ANTICIPATED)

September 1, 2021

Study Registration Dates

First Submitted

August 14, 2014

First Submitted That Met QC Criteria

August 20, 2014

First Posted (ESTIMATE)

August 21, 2014

Study Record Updates

Last Update Posted (ESTIMATE)

August 21, 2014

Last Update Submitted That Met QC Criteria

August 20, 2014

Last Verified

August 1, 2014

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Aortic Valve Stenosis

Clinical Trials on MicroPort's Transcatheter Aortic Valve and Delivery System

3
Subscribe