Ambulatory Fetal Heart Rate Monitoring in Small Babies

April 28, 2017 updated by: Habiba Kapaya, Sheffield Teaching Hospitals NHS Foundation Trust

The Feasibility of Employing Ambulatory Fetal Heart Rate Monitoring in Small for Gestational Age Fetuses at Risk of Stillbirth.

Most babies who measure small during pregnancy are born healthy. However, some are small because they are not growing as expected, usually because the placenta (the baby's 'life support' system) is not working properly. These babies are at greatly increased risk of dying before birth, and need to be delivered before they become poorly.

Scans and electronic heartrate monitoring are currently used to monitor these babies. But they can only be used for short periods and don't always provide enough information to show when to deliver the baby.

A small light monitor has been developed that safely records the baby's heart rate for up to 16hrs by measuring electrical activity through sticky patches on the mum's skin (like a normal ECG). The woman carries on with her daily activities while wearing it. Monitoring the heart rate over a longer time may help with decisions about the timing of the delivery and could prevent stillbirth, the aim of our future study. This will include large numbers of women carrying small babies. Before the investigators can do this the investigators need to know whether:

  1. Wearing the monitor for 16hrs is practical and acceptable to pregnant women
  2. The monitor can provide useful information on the baby's heart rate at different stages of pregnancy.

Thirty pregnant women whose babies are measuring small will be asked to wear the monitor on two occasions, for 16hrs each time. The women will describe what they think about wearing the monitor by completing questionnaires.

The data from the monitor will be downloaded and compared with the woman's medical notes after the participant has delivered her baby. Results from this study will be publicised and will help with the design of the investigators future study into the usefulness of this monitor.

Study Overview

Status

Completed

Conditions

Detailed Description

Study design:

The study has been designed as a prospective, non randomised, single centre feasibility study to determine the acceptability and reliability of the Monica AN24 device, as a method of long-term fetal heart rate (FHR) monitoring on more than one occasion in the antenatal period.

Objectives of the study:

The proposed feasibility study aims to:

  1. Assess the recruitment rates and practicality of the study design and protocol.
  2. Evaluate the acceptability to participants of wearing the device for overnight FHR monitoring on two occasions in pregnancy.
  3. Measure the success rate of generating good quality overnight FHR data and identify any limitations of the technique.
  4. Determine response rates to questionnaires

Recruitment The investigators will recruit women from 28 completed weeks of gestation. The investigators will study each participant on two occasions (2-4 weeks apart). Being a feasibility study FHR data obtained during these experiments will not be employed in the routine clinical care of study participants whose care will follow standard patterns of surveillance employed at the Jessop Wing Hospital (JW), Sheffield.

Statistical analysis:

As this is a feasibility study the investigators will employ mainly descriptive analysis. The investigators will report rates of consent, recruitment and acceptability of wearing the AN24 device on two occasions. The investigators shall also report the rates and duration of obtaining valid FHR data when the device is worn. The feasibility and FHR outcome measures will be summarised and will inform design for future definitive studies.

Future work and clinical impact of this research:

The investigators believe that incorporating ambulatory FHR monitoring to the current methods employed to monitor SGA could predict and prevent stillbirth. This is the overarching aim of our future definitive multicentre study which will require collection of longterm FHR data at different stages of pregnancy from at least 500 women carrying small babies. Data captured from our feasibility study will inform the design of our main study and ensure that our design is robust and that all the potential issues identified in the feasibility study have been addressed.

Study Type

Observational

Enrollment (Anticipated)

30

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Female

Sampling Method

Probability Sample

Study Population

The Investigators will recruit 30 women with a singleton pregnancy (no congenital abnormality) and a customised birth weight ratio of less than 10th centile on ultrasound from the small baby clinic, which is provided at the Fetomaternal Unit (FMU) at the Jessop Wing (JW) Hospital, Sheffield. Each participant will be studied on 2 occasions, 2 to 4weeks apart at their routine hospital visit for serial ultrasound scans.

Description

Inclusion Criteria:

All women with singleton pregnancy from 28 completed weeks of gestation, suspected to carry small for gestational age (SGA) fetus on ultrasound scan but with no known congenital abnormality will be eligible for inclusion in the study if they agree.

Exclusion Criteria:

  • Evidence of a major fetal malformation on ultrasound scan
  • Clinical suspicion of labour
  • Multiple pregnancy
  • Involved in another study using a device or medicinal product

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Cohort
  • Time Perspectives: Prospective

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To assess recruitment rate to the study on first invitation
Time Frame: one year
one year
To estimate proportion of recruited women who demonstrate willingness to wear the monitor two times
Time Frame: one year
In light of investigator's previous work, no problems are anticipated in achieving 30 recruits in a year. However, study would be deemed successful if at least 80% of participants wear the monitor on second occasion and complete the study
one year

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To measure success rate of fetal heart rate data across different stages of pregnancy
Time Frame: one year
Success rate will be presented in percentage.
one year

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

September 1, 2015

Primary Completion (Actual)

November 8, 2016

Study Completion (Actual)

November 11, 2016

Study Registration Dates

First Submitted

November 21, 2015

First Submitted That Met QC Criteria

December 8, 2015

First Posted (Estimate)

December 11, 2015

Study Record Updates

Last Update Posted (Actual)

May 1, 2017

Last Update Submitted That Met QC Criteria

April 28, 2017

Last Verified

April 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • STH18636

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on High Risk Pregnancy

Clinical Trials on Fetal heart rate monitor (Monica AN24)

3