Novel Adenosine-independent Index of Coronary Artery Stenosis Severity Resting Flow Reserve (RFR)

January 28, 2020 updated by: Ajay Kirtane, Columbia University

Derivation and Validation of a Novel Adenosine-independent Index of Coronary Artery Stenosis Severity Resting Flow Reserve

This study will enroll patients who are referred for coronary angiography and require physiological assessment to see if the lesion can be treated as per the local standard of care. Approximately 92 participants will be enrolled. There are no follow up visits required so participation in this study will end when subjects are discharged from the hospital.The study will be comparing the resting flow reserve against the instantaneous wave-free ratio (iFR) and fractional flow reserve. All these tests offer a way to image a legion and determine if it is suitable to be treated. FFR measures the pressure differences across (narrowed coronary arteries usually due to atherosclerosis), iFR's are performed during cardiac catheterisation (angiography) using invasive coronary pressure wires which are placed in the arteries of the heart that are to be assessed and the Resting flow reserve looks at the maximum increase in blood flow through the coronary arteries above the normal resting volume.

Study Overview

Detailed Description

Fractional flow reserve (FFR) measurement by under hyperemic conditions has become the invasive gold standard for determining the physiologic extent of cardiac ischemia, and which has been validated in several clinical outcomes studies as a way of optimizing case selection for percutaneous coronary intervention (PCI). More recently in two large-scale randomized controlled trials using a non-hyperemic resting measurement, the instantaneous wave free ratio (iFR) showed non-inferiority in major adverse cardiovascular events (MACE) comparing iFR to FFR for physiological assessment of moderate coronary stenosis. FFR is calculated as the ratio of the distal coronary pressure to the aortic pressure (Pd/Pa) during maximal micro-circulatory relaxation. iFR is a diagnostic tool used to assess whether a stenosis is causing a limitation of blood flow in coronary arteries with subsequent ischemia. iFR is performed during cardiac catheterization (angiography) using invasive coronary pressure wires which are placed in the coronary arteries that are to be assessed. The iFR negates the time averaging and administration of vasodilators necessary for FFR by identifying from the resting pressure waveform a period when the native microcirculatory resistance is constant and minimized in diastole. The study is looking at the accuracy and precision of a novel adenosine-independent index of coronary artery stenosis, the resting flow reserve, against the instantaneous wave-free ratio and fractional flow reserve.

Study Type

Interventional

Enrollment (Actual)

5

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • New York
      • New York, New York, United States, 10032
        • Columbia University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Age ≥ 18 years.
  2. Patient provides signed written informed consent before any study-specific procedure.
  3. Undergoing coronary angiography, for silent ischemia, stable angina, acute coronary syndrome, or other acceptable indication per the local standard of care.
  4. Angiographically 40%-90% stenosis present in at least one native coronary artery.
  5. Undergoing physiological assessment for standard clinical or diagnostic indications

Exclusion Criteria:

  1. Aorto-ostial lesion location within 3 mm of the aorta junction (both right and left).
  2. Left main stenosis
  3. Vessel(s) and lesion(s) not amenable for percutaneous coronary intervention (PCI) , for example diffuse disease.
  4. Saphenous vein graft, chronic total occlusion
  5. Haemodynamic instability at the time of intervention (heart rate<50 beats per minute, systolic blood pressure <90mmHg), balloon pump
  6. Currently participating in another clinical study that interferes with study results.
  7. Pregnant or nursing subjects and those who plan pregnancy in the period up to 1 year following index procedure.
  8. Any other medical condition that in the opinion of the investigator will interfere with patient safety or study results.
  9. High degree A-V block, sinus node disease.
  10. Asthma/Chronic obstructive pulmonary disease (COPD) with active wheeze
  11. Known hypersensitivity to adenosine
  12. ST-Elevation Myocardial Infarction (STEMI) within 48 hours.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Primary
All patients who are referred for coronary angiography and require physiological assessment of intermediate lesions will have both RFR and iFR measured during their standard of care procedure. Both the RFR wire (St. Jude Medical (SJM) Aeris Pressure Wire System) and iFR (Volcano Verrata Pressure Wire) wire will be advanced across the lesion with the sensor located at least 3 cm distal from the lesion.

Steerable guidewire with a pressure transducer mounted 3cm proximal to the tip. The guidewire has a diameter of 0.014".

and is packaged preconnected to the connector with a torque device to facilitate navigation through the vasculature.

Other Names:
  • iFR Wire
The pressure wire is a 0.014'' guidewire with a pressure and temperature sensor integrated into the tip to enable measurements of physiological parameters.
Other Names:
  • RFR Wire

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage Agreement Between Mean RFR and iFR Measurements
Time Frame: During procedure
Mean RFR measurements will be compared against mean iFR measurements to determine if there is an agreement between RFR and iFR for detection of ischemia.
During procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Lesion Classification (FFR≤/>0.80) by RFR
Time Frame: During procedure
During procedure
Lesion Classification (FFR≤/>0.80) by iFR
Time Frame: During procedure
During procedure
Pressure Drift of RFR
Time Frame: During procedure
During procedure
Pressure Drift of iFR
Time Frame: During procedure
During procedure
Measurement Reproducibility for RFR
Time Frame: During procedure
Reproducibility of RFR will be tested against iFR. Reproducibility will be measured by comparing the measure of RFR (minimal ratio of distal coronary pressure/aortic pressure) at time point 1 versus time point 2 against iFR (minimal ratio of distal coronary pressure/aortic pressure during the wave-free period of diastole) at time point 1 versus time point 2.
During procedure
Measurement Reproducibility for iFR
Time Frame: During procedure
Reproducibility of iFR will be tested against RFR. Reproducibility will be measured by comparing the measure of iFR (minimal ratio of distal coronary pressure/aortic pressure during the wave-free period of diastole) at time point 1 versus time point 2 against RFR (minimal ratio of distal coronary pressure/aortic pressure) at time point 1 versus time point 2.
During procedure
Ability to Advance to the Target Lesion and Measure RFR and iFR
Time Frame: During procedure
Percentage of technical failure due to the inability to deliver the wire and measure out of total number of all procedures
During procedure

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Ajay Kirtane, MD, CUMC

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

October 20, 2017

Primary Completion (Actual)

August 2, 2018

Study Completion (Actual)

August 2, 2018

Study Registration Dates

First Submitted

February 22, 2018

First Submitted That Met QC Criteria

March 5, 2018

First Posted (Actual)

March 12, 2018

Study Record Updates

Last Update Posted (Actual)

February 7, 2020

Last Update Submitted That Met QC Criteria

January 28, 2020

Last Verified

January 1, 2020

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Coronary; Ischemic

Clinical Trials on Volcano Verrata Pressure Wire