Real-time Continuous Glucose Monitoring for Reduced Adverse Complications and Events in Women With Gestational Diabetes (GRACE): a Multicentre International Randomized Controlled Trial (GRACE)
The Effectiveness of Real Time Continuous Glucose Monitoring to Improve Glycemic Control and Pregnancy Outcome in Patients With Gestational Diabetes Mellitus
Study Overview
Status
Intervention / Treatment
Detailed Description
Intervention: Device description The Dexcom G6 intended use is for the management of diabetes in persons aged 2 years and older. The Dexcom G6 System is intended to replace fingerstick blood glucose testing for diabetes treatment decisions. Interpretation of the Dexcom G6 System results should be based on the glucose trends and several sequential readings over time. The Dexcom G6 System also aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments. The Dexcom G6 System can be used alone or in conjunction with these digitally connected medical devices for the purpose of managing diabetes. The system consists of a sensor, transmitter, receiver, and mobile app. The sensor is a small, flexible wire inserted into subcutaneous tissue where it converts glucose into electrical current. The sensor incorporates an interferent layer that minimizes the effect of potential electroactive interferents, such as acetaminophen, by preventing it from reaching the sensor wire surface. The benefit of this interferent layer in blocking the effects of acetaminophen prevents falsely high glucose readings. Thus, users may ingest acetaminophen while wearing the G6 CGM system. The transmitter, which is connected to the sensor and worn on the body, samples the electrical current produced by the sensor and converts the measurement into a glucose reading using an onboard algorithm. The receiver and/or the app displays the glucose reading along with a rate of change arrow and a trend graph. Additionally, the receiver and/or app issues alarms and alerts to notify the patient of glucose level changes and other important system conditions. The app provides the additional capability to share data with "followers" using the Dexcom Share service. The receiver can be put into a blinded mode using CLARITY® software. In this mode, users are unable to see the CGM data or receive CGM alerts.
CGM Ancillary Devices Dexcom CLARITY® is an accessory to users of the Dexcom CGM system. It is a software program that allows the transfer of glucose data from the CGM system to Dexcom remote servers for data management to allow use of the CGM data by the user and study clinicians. Target ranges of 60 to 140 mg/dl [3.3 to 7.8 mmol/l] will be set and the patients will be introduced in the use of alarm settings. Both participants and study sites will use CLARITY® to transfer glucose data between user and study site, whether CGM is used in blinded or real-time mode. A CLARITY® mobile app can be used for retrospective review of glucose data on the smart device and can also be set up to allow receipt of push notifications of CGM data facilitating weekly data review. For all patients (intervention and control group) an anonymized CLARITY® account will be created by using a sequential study number which is allocated at randomization (sex will be female and birth date for each account will be set to 1.1.1990 for all accounts).
- For participants that have a supported phone, the G6 CGM app will be installed on participant's smart phone.
- An anonymized CLARITY® mobile account will be set up and linked to the research site.
- Participants will use CGM data for their diabetes management.
5. A high alert threshold will be set at 140 mg/dl [7.8 mmol/l]. Low alert threshold and urgent low soon alerts will be turned off. If participants require insulin, the low alert will be turned on and the threshold set at 65 mg/dl [3.6 mmol/l]. In addition, the urgent low alert (55 mg/dl [3.1 mmol/l]), the urgent low soon alert (when glucose levels are falling fast and will be below 55 mg/dl [3.1 mmol/l] in less than 20 min) as well as alerts for rise and fall rate (3 mg/dl [0.17 mmol/l]) in addition to alerts for signal loss and no readings for more than 20 min will be enabled. 6. Participants with applicable smart phones may have CLARITY® push notifications on the CLARITY® mobile app about weekly time in range comparison enabled during the study.
7. For app users, the "Share and Follow" functionality will be discussed and encouraged (i.e.
the study participants are able to invite followers to review their glucose levels).
8. For participants using the receiver only, the receiver will be downloaded into the CLARITY® clinic account at each visit. 9. For participants using real-time CGM data summary will be downloaded for documentation at V3 and V4 (between 36+0 and 38+6) as well as after delivery (VPP1) 10. The research team will review the CGM in CLARITY® to inform lifestyle and therapy recommendations. 11. The Dexcom G6 system will not be calibrated during the study period.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Vienna, Austria, 1090
- Department of Obstetrics and Gynecology, Division of Obstetrics and Feto-maternal Medicine, Medical University of Vienna
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- female patients between 18 and 55 years
- gestational diabetes mellitus in accordance with the IADPSG criteria between 24 and 31+6 weeks of gestation by a 2h 75g OGTT
- If the GDM diagnosis is made before 24+0 weeks of gestation in accordance with the local guideline (i.e. when IADPSG cut-offs for fasting and post-load glucose are exceeded) patients can be included if no insulin treatment was started until 24+0
Exclusion Criteria:
- Overt diabetes (i.e. pregestationally known type 1 or type 2 diabetes or fasting plasma glucose during the OGTT ≥126 mg/dl [7.0 mmol/l] or HbA1c ≥6.5% [44 mmol/l] or 2h post-load OGTT levels ≥200 mg/dl [11.1 mmol/l] assessed before 24+0 weeks of gestation
- history of bariatric surgery or other surgeries that induce malabsorption
- long-term use (>2 weeks) of systemic steroids prior to enrolment
- multiple pregnancy
- Patients already using glucose lowering medications (metformin or insulin) before study entry
- fetal growth restriction due to placental dysfunction at study entry - Inpatient psychiatric treatment up to 1 year before enrolment
- Participation in this study in previous pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Active Comparator: self-monitored blood glucose
The control group participants will perform self-monitored blood glucose testing with a study-provided blood glucose meter, including testing supplies.
They will perform capillary blood glucose monitoring as routinely used for patients with GDM i.e. at least four capillary blood glucose values daily including measurements at fasting as well as 1h after starting each meal by using a routinely available blood glucose measurement device.
|
Each participant in the control group will be assigned a study blood glucose meter to measure and store their blood glucose values during the study.
Therefore, the Contour® Next One system (or a comparable device) will be used.
The meter has CE Mark clearance and is commercially available in Europe.
Participants will receive an ample supply of meter test materials based on quantities routinely used.
|
|
Experimental: Continuous glucose monitoring
Patients randomized to the intervention group will be equipped with a real-time CGM sensor (Dexcom G6 sensor, a small flexible device that records interstitial glucose levels every five minutes).
The sensor will be inserted into the subcutaneous tissue of the anterior abdomen wall.
Additionally, patients will be advised to record capillary blood glucose values if glucose alerts or readings do not match with symptoms or expectations.
Participants will be educated how to exchange the sensor (has to be exchanged every ten days) and will be equipped with a real-time CGM monitor and instructed in its use.
The monitor provides the user with information about current glucose levels and notifies the patient before she reaches her upper or lower glucose threshold and when glucose levels change rapidly.
All patients in the intervention group will specifically trained how to use the system.
|
Users insert a tiny sensor wire just under their skin using an automatic applicator.
The sensor can measure glucose readings in interstitial fluid throughout the day and night.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
LGA newborns
Time Frame: postpartum - up to 48 hours after delivery
|
To assess differences in the proportion of LGA newborns (birth weight >90.
pct) in women with GDM using real-time CGM as compared to women with GDM using SMBG via capillary blood glucose monitoring.
|
postpartum - up to 48 hours after delivery
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
neonatal hypoglycaemia
Time Frame: postpartum - up to 48 hours after delivery
|
newborn measurement
|
postpartum - up to 48 hours after delivery
|
|
rate of caesarean section
Time Frame: postpartum - up to 48 hours after delivery
|
statistics
|
postpartum - up to 48 hours after delivery
|
|
shoulder dystocia
Time Frame: postpartum - up to 48 hours after delivery
|
frequency of occurrences
|
postpartum - up to 48 hours after delivery
|
|
neonatal anthropometry
Time Frame: postpartum - up to 48 hours after delivery
|
newborn measurement
|
postpartum - up to 48 hours after delivery
|
|
differences in neonatal hyperinsulinemia
Time Frame: postpartum - up to 48 hours after delivery
|
differences in neonatal hyperinsulinemia
|
postpartum - up to 48 hours after delivery
|
|
CGM measures such as mean, glycaemic variability, time in range as well as hyper- and hypoglycaemia
Time Frame: through study completion, an average of 9 months
|
maternal measurements
|
through study completion, an average of 9 months
|
|
duration and frequency postprandial hyperglycaemic excursions
Time Frame: through study completion, an average of 9 months
|
maternal
|
through study completion, an average of 9 months
|
|
start and amount of glucose lowering therapy
Time Frame: through study completion, an average of 9 months
|
development until birth
|
through study completion, an average of 9 months
|
|
HbA1c
Time Frame: through study completion, an average of 9 months
|
maternal measurements
|
through study completion, an average of 9 months
|
|
glycosylated Fibronectin
Time Frame: through study completion, an average of 9 months
|
maternal measurements
|
through study completion, an average of 9 months
|
|
change in bodyweight during pregnancy and after delivery as well as glucose disposal at postpartum
Time Frame: through study completion, an average of 1 year
|
development until birth
|
through study completion, an average of 1 year
|
|
Health-related quality of life
Time Frame: through study completion, an average of 9 months
|
development until birth
|
through study completion, an average of 9 months
|
Collaborators and Investigators
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 20181101
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Pregnancy Complications
-
University Hospital, MontpellierInstitut National de la Santé Et de la Recherche Médicale, FranceNot yet recruiting
-
Kafrelsheikh UniversityNot yet recruitingEctopic PregnancyEgypt
-
Meir Medical CenterRecruiting
-
Northwestern UniversityTerminatedPregnancy Related | Labor ComplicationUnited States
-
Bagcilar Training and Research HospitalRecruitingEctopic PregnancyTurkey (Türkiye)
-
The George Washington University Biostatistics...Eunice Kennedy Shriver National Institute of Child Health and Human Development...Terminated
-
Oslo University HospitalRecruitingPregnancy Related | Labor Complication | Induced; BirthNorway
-
University of PennsylvaniaRecruitingEarly PregnancyUnited States
-
Medical College of WisconsinBill and Melinda Gates FoundationRecruiting
-
Washington University School of MedicineUniversity of MichiganRecruiting
Clinical Trials on self-monitored blood glucose
-
University of California, IrvineNational Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)RecruitingHemodialysis | Diabete Mellitus | Continuous Glucose MonitoringUnited States
-
Second Affiliated Hospital of Wenzhou Medical UniversityNot yet recruiting
-
Heilongjiang University of Chinese MedicineUnknownPolycystic Ovary SyndromeChina
-
Vastra Gotaland RegionThe Swedish Research Council; Abbott Medical DevicesNot yet recruiting
-
Karolinska InstitutetRegion StockholmCompletedAnxiety | Depressive SymptomsSweden
-
Yuwen ZhangCompletedDiabetes Mellitus, Type 2China
-
The George Washington University Biostatistics...Eunice Kennedy Shriver National Institute of Child Health and Human Development...Completed
-
HealthPartners InstituteLifeScan; International Diabetes Center at Park NicolletCompletedType 2 DiabetesUnited States
-
Manchester University NHS Foundation TrustDexCom, Inc.CompletedDiabetes Mellitus, Type 1United Kingdom
-
Oregon Health and Science UniversityDexCom, Inc.CompletedGestational DiabetesUnited States