Skeletal Stability of Le Fort I Osteotomy Using Patient-specific Osteosynthesis Compared to Mini-plate Fixation for Patients With Dentofacial Disharmony

May 30, 2022 updated by: Hassan Fahmy Hassan Alnimr

Skeletal Stability of Le Fort I Osteotomy Using Patient-specific Osteosynthesis Compared to Mini-plate Fixation for Patients With Dentofacial Disharmony. A Randomized Controlled Clinical Trial

The aim of the study is to evaluate the Skeletal stability of Le Fort I osteotomy using patient-specific osteosynthesis compared to Mini-plate fixation for patients with skeletal class III malocclusion.

Study Overview

Detailed Description

postsurgical relapse is one of the most common observations that have been reported after fixation of Le Fort I osteotomy cases.

Fixation systems with plates and screws are used in oral maxillofacial surgery for the treatment of facial fractures and orthognathic surgery cases. Although they have been used for decades and have become the standard treatment, the materials used in these systems may fail due to excess loading and other causal factors during the surgical procedure, including failure in plate adaptation and fixation to bone, material design, fabrication, and degree of purity of the plate material.

In the fixation system, non-customized plates of standard size are used, and are bent to adapt them to the distances required for planning orthognathic surgeries. Therefore, mandatory use of larger plates than those programmed for use in surgeries is required so that they can be bent to enable insertion. Moreover, there are variations in the number of screws required to retain the plates to enable better fixation. The folds of non-customized plates generate stresses that are minimized when using customized plates, because these plates are fabricated individually, with predetermined sizes for each patient.

Study Type

Interventional

Enrollment (Anticipated)

30

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 40 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Patients with skeletal class III malocclusion planned for traditional Orthognathic Approach and requiring bimaxillary orthognathic surgeries in which there will be Le Fort I osteotomy with maxillary advancement ranging from 2mm to 5 mm in addition to mandibular setback.
  2. Patients with no signs or symptoms of active TMDs.
  3. Highly motivated patients.

Exclusion Criteria:

  1. Patients who refused to be included in the research.
  2. Patients with systemic diseases that may hinder the normal healing process or render the patient not fitting for general anaesthesia.
  3. Patients with intra-bony lesions or infections that may retard the osteotomy healing.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Group I (Conventional plates)

Digital intermediate and final interocclusal wafer splints will be designed to guide the maxilla and mandible in the desired position using CAD software (3-matic 11.0; Materialise NV, Leuven, Belgium).

The designed splints will be then exported in stereolithography (STL) file format to the additive CAM machine (FORMIGA P 110 printer; EOS e-manufacturing solutions, Munich, Germany) and manufactured in white polyamide (PA2200; EOS e-manufacturing solutions, Munich, Germany) using fused deposition modelling (FDM) technology.The splints will be cold sterilized by overnight immersion in 2% glutaraldehyde.

2.0 conventional mini plates will be used for fixation of maxilla and mandible in the new position.

le fort I osteotomy will carried out in the classic way guided by the classic landmarks (maxillary roots apices) as described by Wassmund.

Complete separation of the maxillary segment using chisels and mallets in regular fashion.

Reposition maxilla using the interocclusal wafer while mandible is gently positioned to centric relation position.

Mandible is maintained in place until fixation of the maxilla with plates and screws takes place.

Complete separation of the mandibular segment using chisels and mallets in regular fashion.

Repositioning of mandible using the final interocclusal wafer while condylar segment is gently positioned to centric relation position.

Fixation of mandibular segments with plates and/or screws in regular fashion.

Incision was closed with 4-0 resorbable sutures in a continuous running fashion.

Experimental: Group II (Patient specific plates)

The cutting guides will be designed on the maxilla and mandible to orient the osteotomy and mark reference holes to be used later for the repositioning/ fixation plate, using CAD software.

The designed guide will be then exported in stereolithography (STL) file format to the additive CAM machine and manufactured in white polyamide using fused deposition modelling (FDM) technology. No finishing or polishing was done in order to maintain accuracy. The guides will be cold sterilized by overnight immersion in 2% glutaraldehyde.

The patient-specific osteosynthesis plates will be designed to fix the maxilla and mandible in the desired position making use of the previously established reference holes. The designed plates will be exported in STL file format to be manufactured in grade 5 titanium alloy utilizing selective laser sintering (SLS) technology on an additive CAM machine.

The cutting guide of the maxilla will be placed onto the exposed bony surface and manipulated to the best fit.

Then, the guide will be fixed using four 2.0-mm screws to avoid any mobilization during drilling of the reference holes. Sixteen reference holes will be established using the cutting guide; eight on each side.

Then, a reciprocating saw will be used to perform the planned Le Fort I osteotomy. After adequate maxillary mobilization and removal of bony interferences, the maxilla will be repositioned using the patient-specific osteosynthesis material guided by the previously established reference holes and fixed using 2.0-mm screws.

Then, the mandibular cutting guide will be fixed in the same manner and bilateral sagittal split osteotomy will be carried out.

After adequate mobilization, the mandible will be repositioned by the patient-specific osteosynthesis material using the reference holes made by cutting guide and fixed using 2.0-mm screws.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Skeletal relapse of Le Fort I osteotomy
Time Frame: Linear deviations between immediate postoperative and 12 months postoperative position
Skeletal relapse will be assessed through measuring Linear deviations (DT) between the immediate postoperative (T1) and the 12 months postoperative position (T2) in Mimics 19.0 software using hard tissue reference points (A point, Anterior nasal spine, posterior nasal spine, Incisive foramen, Right side Greater palatine foramen, Left side Greater palatine foramen) in relation to three reference planes (Frankfort horizontal plane (FHP), coronal plane, and mid-facial plane (MFP)). Measurements from the reference points to the FHP indicated vertical deviation, to the coronal plane indicated anteroposterior deviation, and to the MFP indicated mediolateral deviation. measurements will be in millimeters.
Linear deviations between immediate postoperative and 12 months postoperative position

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Hassan Alnimr, Cairo University

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

May 26, 2022

Primary Completion (Anticipated)

November 1, 2023

Study Completion (Anticipated)

December 1, 2023

Study Registration Dates

First Submitted

April 4, 2022

First Submitted That Met QC Criteria

April 20, 2022

First Posted (Actual)

April 21, 2022

Study Record Updates

Last Update Posted (Actual)

June 1, 2022

Last Update Submitted That Met QC Criteria

May 30, 2022

Last Verified

May 1, 2022

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

Individual participant data will not be available to other researchers.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.