Performance Evaluation of the ex Utero Cord Blood Collection Technique: Procedure, Quality and Results

October 1, 2024 updated by: Nimet Caner, Institut Universitari Dexeus

Umbilical cord blood (UCB) is used for leukemia patients and other serious blood disorders worldwide. (3) It has also been recently used for other therapeutic applications such as wound treatment, red blood cell transfusion, or cellular or regenerative therapy. Until now, cord blood banks have worked to have many units in reserve to offer maximum compatibility with patients.

The priority is to increase the quality of cord blood by collecting units that have more stem cells with less contamination so that more patients can benefit, that is, improving the efficiency of the process.

The conventional in utero technique allowed for a more rapid diffusion of cord blood donation programs as it does not require accessories or additional personnel to carry it out. The UCB donation program was initiated in Catalonia in 1995, and since then, this has been the technique used (www.bancsang.net/info-corporativa/qui-som). Some comparisons have been made in the scientific literature with the results found . Currently, there are some new applications of UCB that require its use in fresh form, and it would be beneficial to minimize the risk of bacterial contamination that seems to be reduced with ex utero collection. Therefore, the proposition for this study is to confirm equivalence in quality characteristics and create opportunities for its extensive application.

Currently, cord blood donation is offered to all expectant mothers, provided that the donor does not have any medical exclusion. A very small number of the collected units are suitable for clinical use once processed, making donation programs truly inefficient. This inefficiency generates a workload and waste of public resources that are limited and can also cause ethical dilemmas. Therefore, new strategies are needed to increase the efficiency of donation programs. The Blood and Tissue Bank (BST) has an efficiency improvement study underway using the ex-utero collection technique. The development of this methodology will allow later to propose expanded collection methods, such as the simultaneous collection of cord blood and placenta.

The update of new protocols in childbirth care encourages to explore new systematic umbilical cord blood collection methods with the following objectives: to intervene less in the delivery room obtaining products of equal quality and less contamination and to facilitate the simultaneous donation of UCB and placenta in the future. To ensure that the units have maximum quality, both cellular and free of bacteriology, and can be used safely, the investigators propose the implementation of ex utero cord blood collection. The ex-utero UCB collection involves minimal manipulation, allowing for better cord asepsis. After the birth of the baby and cord clamping at one minute, the investigators wait for the delivery of the placenta and proceed to obtain the ex-utero UCB sample. Thanks to this technique, residual cord blood can be obtained, and the placenta can be collected simultaneously, maintaining the same volume as in in utero collection and reducing contamination and hemolysis of the samples.

This technique poses no risk to either the mother or the baby. The ex-utero cord blood collection technique is a validated technique used in different studies.

To verify these data in our environment and propose a change in the cord blood collection strategy in public banks, this study has been designed.

If the investigators demonstrate that this methodology meets quality objectives, similar to the in-utero technique but significantly reducing associated contamination from the delivery field and the presence of hemolysis, the cord blood bank can implement this new systematic method in centers with highly trained collection personnel, releasing obstetric professionals from their intervention in the delivery room and favoring better quality of the products obtained.

Study Overview

Study Type

Interventional

Enrollment (Actual)

133

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Barcelona, Spain, 08037
        • Departamento de Ginecología Obstetricia y Reproducción. Hospital Universitari Dexeus

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult

Accepts Healthy Volunteers

Yes

Description

Inclusion Criteria:

  • 18 years old
  • Geographical origin and history of known travels
  • Absence of potentially transmissible diseases (infectious, hematological, and autoimmune)
  • Absence of diseases that can alter prenatal obstetric variables: multiple pregnancy, pregestational diabetes mellitus, intrauterine growth restriction, hypertensive states of pregnancy or chronic arterial hypertension, and fetal pathology.
  • Any type of delivery: vaginal delivery and cesarean section.
  • Deliveries from week 37 or higher.
  • Standardization of the timing of clamping in all cases to one minute.

Exclusion Criteria:

  • Pregnant women who meet the exclusion criteria to be cord blood donors.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Ex-utero cord blood collection
SCU units are collected after placental delivery (ex-utero) by trained obstetric personnel. The cord is clamped at one minute postpartum. Once the placenta is expelled, it is rapidly transported to the collection area, which contains supplies and a surgical table designed for ex-utero SCU collection. This table has a top tray supported by an armrest. The placenta is placed on this specially designed tray with a central hole that allows the umbilical cord to hang. Proper asepsis of the cord is first performed with povidone-iodine and then with 70% alcohol. Subsequently, the umbilical vein is cannulated at the most distal point of the placenta, and placental blood is collected by gravity into a sterile bag. Gentle massage can be applied to the placenta to continue draining blood by gravity. If visible blood remains, a second puncture can be made by bringing the needle insertion point closer to the placenta.
Active Comparator: In-utero cord blood collection
The cord blood is clamped in a delayed modality, defined as after at least 1 minute after delivery. The cord is sterilized, and cord blood is collected using aseptic technique (proper asepsis of the cord is first performed with povidone-iodine and then with 70% alcohol). Blood is allowed to flow by gravity and the needle is removed when blood flow ceases.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Weight of cord blood collection
Time Frame: At delivery

have a minimum weight of 85 grams. Subsequently, the efficiency for certain uses will be evaluated:

  • Biobank for culture media: from 85 to 100 grams
  • Multicomponent cord blood: > 100 grams and less than 1.5 billion leukocytes
  • Transplant: > 100 grams and greater than 15 billion leukocytes
At delivery

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Leukocytes
Time Frame: At delivery
(White Blood Cells) : cells/µL
At delivery
Red blood cells
Time Frame: At delivery
million/µL
At delivery
Hematocrit
Time Frame: At delivery
percentage
At delivery
Platelets
Time Frame: At delivery
unit of measurement: cells/µ
At delivery
CD34+ cells
Time Frame: At delivery
CD34+ cells are hematopoietic stem cells, meaning cells that can differentiate into various types of blood cells. The amount of CD34+ cells in cord blood is an indicator of the sample's ability to generate new blood cells.
At delivery
Bacteriology
Time Frame: At delivery
presence/absence. Bacteriology is the study of bacteria present in a biological sample. In the case of cord blood, a bacteriological analysis is performed to detect the presence of bacteria that may affect the sample's quality.
At delivery
Hemolysis
Time Frame: At delivery
presence/absence. Hemolysis is the rupture of red blood cells and the release of their contents into the blood. The presence of hemolysis in cord blood may indicate poor sample quality.
At delivery

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Helpful Links

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 1, 2023

Primary Completion (Actual)

June 10, 2024

Study Completion (Actual)

September 25, 2024

Study Registration Dates

First Submitted

April 19, 2023

First Submitted That Met QC Criteria

April 28, 2023

First Posted (Actual)

May 1, 2023

Study Record Updates

Last Update Posted (Actual)

October 2, 2024

Last Update Submitted That Met QC Criteria

October 1, 2024

Last Verified

October 1, 2024

More Information

Terms related to this study

Other Study ID Numbers

  • FSD-BST-2022-08

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Umbilical Cord Blood

Clinical Trials on Ex-utero cord blood collection

Subscribe