Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With a GFR Below 60 mL/Min/1.73 m² (DUSIR)
Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With Chronic Kidney Disease
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Objective: To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance.
Method: Single-center interventional study. After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR.
The inclusion criteria are: - Patients older than 18 years of age - Having given written consent to participate in the study. - Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan. - With an estimated GFR according to CKD-EPIcreat2009 < 60 ml/min/1.73m² - Hospitalized or outpatient. - Affiliated with French national health insurance.
The exclusion criteria are: - Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable. - Lack of health insurance - Patients under legal protection.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Thomas STEHLE, Dr
- Phone Number: +33145178452
- Email: thomas.stehle@aphp.fr
Study Locations
-
-
Île-de-France
-
Créteil, Île-de-France, France, 94000
- Assistance Publique Hôpitaux de Paris - CHU Henri Mondor - Créteil
-
Contact:
- Thomas STEHLE, Dr
- Phone Number: +33145178452
- Email: thomas.stehle@aphp.fr
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients older than 18 years of age
- Having given written consent to participate in the study
- Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan
- With an estimated GFR according to CKD-EPIcreat2009 < 60 ml/min/1.73m²
- Hospitalized or outpatient
- Affiliated with French national health insurance
Exclusion Criteria:
- Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable
- Lack of health insurance
- Patients under legal protection.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: GFR Measurement Using 4-Phase CT Urography and Comparison with Iohexol Clearance
A study with one arm, adding experimental procedures to standard of care (a 4-phase CT urography and biological sampling) in order to evaluate the accuracy of GFR measurement by CT urography in patients with chronic kidney disease.
|
After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan.
No iohexol will be reinjected to measure GFR.
The CT scan images will be segmented by the investigator to determine the CT-measured GFR.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Assessment of the Reliability of GFR Measurement by 4-Phase CT Urography Compared to Iohexol Clearance
Time Frame: Day 1
|
To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73
m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero).
- and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance.
|
Day 1
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Reliability Assessment of GFR Estimation Using Creatinine and/or Cystatin C Compared to Iohexol Clearance
Time Frame: Day 1
|
This outcome measure assesses the reliability of glomerular filtration rate (GFR) estimated from serum creatinine and/or cystatin C levels by comparing it to the biological measurement of iohexol clearance.
|
Day 1
|
|
Reliability of Hybrid GFR (Mean of CT-Measured and Creatinine/Cystatin C Estimated GFR)
Time Frame: Day 1
|
This outcome measure evaluates the reliability of the hybrid GFR, defined as the average of the GFR measured by 4-phase CT urography and the GFR estimated from serum creatinine and cystatin C. The reliability will be compared to that of CT-measured GFR alone and creatinine/cystatin C-based estimated GFR,
|
Day 1
|
|
Reliability of CT-Measured GFR Across Patient Subgroups Defined by Estimated GFR Ranges
Time Frame: Day 1
|
This outcome measure assesses the reliability of GFR measured by 4-phase CT urography within different patient subgroups based on their estimated GFR values: between 45 and 60 ml/min/1.73m²,
between 30 and 44 ml/min/1.73m²,
and less than 30 ml/min/1.73m²
|
Day 1
|
Collaborators and Investigators
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- APHP250438
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.