Closed-loop Oxygen Control for High Flow Nasal Therapy (HILOOP)
Safety and Efficacy of a Closed-loop Oxygen Control for High Flow Nasal Therapy in ICU Patients: a Randomized Cross-over Study (The HILOOP Study)
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Barcelona, Spanien, 08035
- Hospital Universitari Vall d'Hebron
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Adult (>17yo) patients admitted to the ICU treated with HFNT for at least 8h
- Requiring FiO2 ≥ 30% to keep SpO2 in the target ranges defined by the clinician
- Written informed consent signed and dated by the patient or one relative in case that the patient is unable to consent, after full explanation of the study by the investigator and prior to study participation.
Exclusion Criteria:
- Patient with indication for immediate continuous positive airway pressure (CPAP), noninvasive ventilation (NIV), or invasive mechanical ventilation
- Hemodynamic instability defined as a need of continuous infusion of epinephrine or norepinephrine > 1 mg/h
- Low quality on the SpO2 measurement using finger and ear sensor (quality index below 60% on the Massimo SpO2 sensor, which is displayed by a red or orange colour bar)
- Severe acidosis (pH ≤ 7.30)
- Pregnant woman
- Patients deemed at high risk for need of mechanical ventilation within the next 8 hours
- Chronic or acute dyshemoglobinemia: methemoglobin, carbon monoxide (CO) poisoning, sickle cell disease
- Tracheotomised patient
- Formalized ethical decision to withhold or withdraw life support
- Patient under guardianship
- Patient deprived of liberties
- Patient included in another interventional research study under consent
- Patient already enrolled in the present study in a previous episode of acute respiratory failure
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Crossover-Aufgabe
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Experimental: Oxygen close-loop
Four hours period where the fraction of inspired oxygen delivered will be automatically titrated based on SpO2 values.
|
The Automatic FiO2 option provides automated adjustment of the ventilator Oxygen setting to maintain the patient's SpO2 in a defined target range.
When using the software option, the user defines the SpO2 target range, as well as the SpO2 emergency limits, and the device adjusts the Oxygen setting to keep the patient's SpO2 in the target range.
|
|
Aktiver Komparator: Manual FiO2 adjustment
Four hours period where the fraction of inspired oxygen delivered will be manually adjusted by the healthcare personnel based on SpO2 values.
|
Manual FiO2 adjustment according to SpO2 values
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Percentage of time spent in optimal SpO2 range
Zeitfenster: 4 hours
|
The optimal SpO2 range will be defined according to the SpO2 targets determined by the clinician.
|
4 hours
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Percentage of time spent in sub-optimal SpO2 range
Zeitfenster: 4 hours
|
SpO2 values outside the optimal range but still within an acceptable limit (2-3 percent above and below the optimal range)
|
4 hours
|
|
Percentage of time spent out of range
Zeitfenster: 4 hours
|
Above or below the suboptimal limits specified at the begginning of the study
|
4 hours
|
|
Percentage of time with SpO2 signal available
Zeitfenster: 4 hours
|
Time with SpO2 signal available
|
4 hours
|
|
Mean SpO2/FiO2
Zeitfenster: 4 hours
|
Mean oxygenation value
|
4 hours
|
|
ROX index
Zeitfenster: 4 hours
|
Is a predictor of HFNT success/failure defined as (SpO2/FiO2)/respiratory rate
|
4 hours
|
|
Percentage of time with SpO2 below 88 and 85 percent
Zeitfenster: 4 hours
|
Duration of time with SpO2 <85 percent and <88 percent, respectively
|
4 hours
|
|
Number of events with SpO2 below 88 and 85 percent
Zeitfenster: 4 hours
|
Frequency of SpO2 decreases <85 percent and <88 percent, respectively
|
4 hours
|
|
Mean FiO2
Zeitfenster: 4 hours
|
Mean fraction of inspired oxygen
|
4 hours
|
|
Percentage of time with FiO2 below 40 percent and above 60%
Zeitfenster: 4 hours
|
Percentage of time that FiO2 is <40 percent and >60 percent, respectively
|
4 hours
|
|
Number of manual adjustments
Zeitfenster: 4 hours
|
Frequency of manual adjustments of FiO2
|
4 hours
|
|
Number of alarms
Zeitfenster: 4 hours
|
Frequency of alarms
|
4 hours
|
|
Patient comfort
Zeitfenster: 4 hours
|
Comfort score by visual analogic scale (from 0 to 10)
|
4 hours
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Helmerhorst HJ, Roos-Blom MJ, van Westerloo DJ, de Jonge E. Association Between Arterial Hyperoxia and Outcome in Subsets of Critical Illness: A Systematic Review, Meta-Analysis, and Meta-Regression of Cohort Studies. Crit Care Med. 2015 Jul;43(7):1508-19. doi: 10.1097/CCM.0000000000000998.
- L'Her E, Dias P, Gouillou M, Riou A, Souquiere L, Paleiron N, Archambault P, Bouchard PA, Lellouche F. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017 Jul 20;50(1):1602552. doi: 10.1183/13993003.02552-2016. Print 2017 Jul.
- Arnal JM, Garnero A, Novotni D, Corno G, Donati SY, Demory D, Quintana G, Ducros L, Laubscher T, Durand-Gasselin J. Closed loop ventilation mode in Intensive Care Unit: a randomized controlled clinical trial comparing the numbers of manual ventilator setting changes. Minerva Anestesiol. 2018 Jan;84(1):58-67. doi: 10.23736/S0375-9393.17.11963-2. Epub 2017 Jul 5.
- Roca O, Caritg O, Santafe M, Ramos FJ, Pacheco A, Garcia-de-Acilu M, Ferrer R, Schultz MJ, Ricard JD. Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study). Crit Care. 2022 Apr 14;26(1):108. doi: 10.1186/s13054-022-03970-w.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- PR(AG)539/2020
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .